A non-dimensional analysis of a ventilated double facade energy performance

被引:58
|
作者
Balocco, C [1 ]
机构
[1] Univ Florence, Dipartimento Energet S Stecco, Florence, Italy
关键词
non-dimensional numbers; ventilated double facade; simulation;
D O I
10.1016/S0378-7788(03)00086-0
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A method based on dimensional analysis is proposed for a natural ventilated double facade energy performance study. The 14 non-dimensional numbers defined, with physical meaning, can be used to describe thermal and energy performance of different facade designs. A comparison between non-dimensional numbers solved by simulation, experimental data, and the obtained and validated correlation results is reported. A simple tool to evaluate thermal performance of a solar chimney is provided. Applying it, useful design indications can be derived also by varying simple parameters using thermal and physical data easy to get. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 40
页数:6
相关论文
共 50 条
  • [21] Non-dimensional Stress Analysis of an Orthotropic Plate
    Kalita, Kanak
    Shinde, Dinesh
    Thomas, Tiju T.
    MATERIALS TODAY-PROCEEDINGS, 2015, 2 (4-5) : 3527 - 3533
  • [22] Reliability analysis based on non-dimensional parameters
    Castillo, EF
    Fraile, A
    Alarcón, E
    Fernández-Canteli, A
    FORESIGHT AND PRECAUTION, VOLS 1 AND 2, 2000, : 1513 - 1518
  • [23] AN ALTERNATE MEANS TO FORM NON-DIMENSIONAL PRODUCTS IN DIMENSIONAL ANALYSIS
    Clark, John P.
    PROCEEDINGS OF ASME TURBO EXPO 2022: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2022, VOL 5, 2022,
  • [24] Climatic based consideration of Double Skin Facade system-comparative analysis of energy performance of a Double Skin Facade Building in Boston
    Azarbayjani, Mona
    Mehta, Jigisha
    SYMPOSIUM ON SIMULATION FOR ARCHITECTURE AND URBAN DESIGN 2012 (SIMAUD 2012), 2012, 44 (08): : 106 - 113
  • [25] Non-dimensional analysis of shot peening by means of DoE
    Baragetti, S
    Terranova, A
    INTERNATIONAL JOURNAL OF MATERIALS & PRODUCT TECHNOLOGY, 2000, 15 (1-2): : 131 - 141
  • [26] Ventilation performance of a naturally ventilated double skin facade with low-e glazing
    Tao, Yao
    Zhang, Haihua
    Huang, Dongmei
    Fan, Chuangang
    Tu, Jiyuan
    Shi, Long
    ENERGY, 2021, 229
  • [27] Non-dimensional physics of pulsatile cardiovascular networks and energy efficiency
    Yigit, Berk
    Pekkan, Kerem
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2016, 13 (114)
  • [28] An experimental sensitivity analysis on the summer thermal performance of an Opaque Ventilated Facade
    Fantucci, Stefano
    Serra, Valentina
    Carbonaro, Corrado
    ENERGY AND BUILDINGS, 2020, 225
  • [29] New non-dimensional performance parameters for the characterization of refrigeration compressors
    Navarro-Peris, Emilio
    Corberan, Jose M.
    Falco, Luigi
    Martinez-Galvan, Israel O.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (07): : 1951 - 1964
  • [30] Non-dimensional groups for similarity analysis of thermoacoustic instabilities
    Silva, Camilo E.
    Polifke, Wolfgang
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2019, 37 (04) : 5289 - 5297