X-ray phase tomography with a Talbot interferometer in combination with an X-ray imaging microscope

被引:5
|
作者
Momose, Atsushi [1 ]
Takeda, Yoshihiro [1 ]
Yashiro, Wataru [1 ]
Takeuchi, Akihisa [2 ]
Suzuki, Yoshio [2 ]
机构
[1] Univ Tokyo, Dept Adv Mat Sci, Grad Sch Frontier Sci, 5-1-5 Kashiwanoha, Chiba 2778561, Japan
[2] JASRI, SPring 8, Mikazuki, Hyogo 6795198, Japan
关键词
D O I
10.1088/1742-6596/186/1/012044
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
An X-ray Talbot interferometer was combined with an X-ray imaging microscope to generate differential phase contrast. X-ray phase tomography was attained based on the measurement of the differential phase shift using the fringe scanning method. Polymer blend samples were observed and phase separation structures were depicted. The spatial resolution was 1.3 mu m in this test experiment, which will be easily improved by increasing the magnification.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Differential Phase X-ray Imaging Microscopy with X-ray Talbot Interferometer
    Takeda, Yoshihiro
    Yashiro, Wataru
    Hattori, Tadashi
    Takeuchi, Akihisa
    Suzuki, Yoshio
    Momose, Atsushi
    APPLIED PHYSICS EXPRESS, 2008, 1 (11) : 1170021 - 1170023
  • [2] Phase tomography using X-ray Talbot interferometer
    Momose, A.
    Yashiro, W.
    Takeda, Y.
    Moritake, M.
    Uesugi, K.
    Suzuki, Y.
    Hattori, T.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1365 - +
  • [3] Phase tomography using an X-ray Talbot interferometer
    Momose, A
    Kawamoto, S
    Koyama, I
    Suzuki, Y
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 352 - 360
  • [4] High-speed X-ray phase imaging and X-ray phase tomography with Talbot interferometer and white synchrotron radiation
    Momose, Atsushi
    Yashiro, Wataru
    Maikusa, Hirohide
    Takeda, Yoshihiro
    OPTICS EXPRESS, 2009, 17 (15): : 12540 - 12545
  • [5] X-ray Phase Laminography with Talbot Interferometer
    Harasse, Sebastien
    Hirayama, Nozomi
    Yashiro, Wataru
    Momose, Atsushi
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VII, 2010, 7804
  • [6] Phase tomography by X-ray Talbot interferometry for biological imaging
    Momose, Atsushi
    Yashiro, Wataru
    Takeda, Yoshihiro
    Suzuki, Yoshio
    Hattori, Tadashi
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (6A): : 5254 - 5262
  • [7] Sensitivity of X-ray Phase Tomography Based on Talbot and Talbot-Lau Interferometer
    Momose, Atsushi
    Yashiro, Wataru
    Takeda, Yoshihiro
    Maikusa, Norihide
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VI, 2008, 7078
  • [8] Fabrication of X-Ray Gratings Using X-Ray Lithography Technique for X-Ray Talbot Interferometer
    Noda, Daiji
    Tsujii, Hiroshi
    Takahashi, Naoki
    Hattori, Tadashi
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2009, 156 (05) : H299 - H302
  • [9] Fabrication of high precision X-ray mask for X-ray grating of X-ray Talbot interferometer
    Noda, Daiji
    Tsujii, Hiroshi
    Takahashi, Naoki
    Hattori, Tadashi
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2010, 16 (8-9): : 1309 - 1313
  • [10] Fabrication of high precision X-ray mask for X-ray grating of X-ray Talbot interferometer
    Daiji Noda
    Hiroshi Tsujii
    Naoki Takahashi
    Tadashi Hattori
    Microsystem Technologies, 2010, 16 : 1309 - 1313