X-ray phase tomography with a Talbot interferometer in combination with an X-ray imaging microscope

被引:5
|
作者
Momose, Atsushi [1 ]
Takeda, Yoshihiro [1 ]
Yashiro, Wataru [1 ]
Takeuchi, Akihisa [2 ]
Suzuki, Yoshio [2 ]
机构
[1] Univ Tokyo, Dept Adv Mat Sci, Grad Sch Frontier Sci, 5-1-5 Kashiwanoha, Chiba 2778561, Japan
[2] JASRI, SPring 8, Mikazuki, Hyogo 6795198, Japan
关键词
D O I
10.1088/1742-6596/186/1/012044
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
An X-ray Talbot interferometer was combined with an X-ray imaging microscope to generate differential phase contrast. X-ray phase tomography was attained based on the measurement of the differential phase shift using the fringe scanning method. Polymer blend samples were observed and phase separation structures were depicted. The spatial resolution was 1.3 mu m in this test experiment, which will be easily improved by increasing the magnification.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] X-ray computed tomography using projection X-ray microscope
    Yoshimura, F
    Miyata, C
    Kuzuryu, C
    Hori, A
    Obi, T
    Ohyama, N
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 166 - 171
  • [22] Dual energy phase contrast x-ray imaging with Talbot-Lau interferometer
    Kottler, Christian
    Revol, Vincent
    Kaufmann, Rolf
    Urban, Claus
    JOURNAL OF APPLIED PHYSICS, 2010, 108 (11)
  • [23] Non-binary phase gratings for x-ray imaging with a compact Talbot interferometer
    Yaroshenko, Andre
    Bech, Martin
    Potdevin, Guillaume
    Malecki, Andreas
    Biernath, Thomas
    Wolf, Johannes
    Tapfer, Arne
    Schuettler, Markus
    Meiser, Jan
    Kunka, Danays
    Amberger, Maximilian
    Mohr, Juergen
    Pfeiffer, Franz
    OPTICS EXPRESS, 2014, 22 (01): : 547 - 556
  • [24] High-Speed X-ray Phase Tomography with Talbot Interferometer and Fringe Scanning Method
    Kibayashi, Shunsuke
    Harasse, Sebastien
    Yashiro, Wataru
    Momose, Atsushi
    INTERNATIONAL WORKSHOP ON X-RAY AND NEUTRON PHASE IMAGING WITH GRATINGS, 2012, 1466 : 261 - 265
  • [25] Analysis of polychromaticity effects in X-ray Talbot interferometer
    Wang, Zhili
    Zhu, Peiping
    Huang, Wanxia
    Yuan, Qingxi
    Liu, Xiaosong
    Zhang, Kai
    Hong, Youli
    Zhang, Huitao
    Ge, Xin
    Gao, Kun
    Wu, Ziyu
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (06) : 2137 - 2141
  • [26] Four-dimensional X-ray phase tomography with Talbot interferometer and white synchrotron light
    Momose, Atsushi
    Yashiro, Wataru
    Harasse, Sebastien
    Kuwabara, Hiroaki
    Kawabata, Katsuyuki
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VII, 2010, 7804
  • [27] Fabrication of diffraction grating for X-ray Talbot interferometer
    Masatake Matsumoto
    Kinji Takiguchi
    Makoto Tanaka
    Yoichi Hunabiki
    Hiroaki Takeda
    Atsushi Momose
    Yuichi Utsumi
    Tadashi Hattori
    Microsystem Technologies, 2007, 13 : 543 - 546
  • [28] Fabrication of diffraction grating for X-ray Talbot interferometer
    Matsumoto, Masatake
    Takiguchi, Kinji
    Tanaka, Makoto
    Hunabiki, Yoichi
    Takeda, Hiroaki
    Momose, Atsushi
    Utsumi, Yuichi
    Hattori, Tadashi
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2007, 13 (5-6): : 543 - 546
  • [29] Analysis of polychromaticity effects in X-ray Talbot interferometer
    Zhili Wang
    Peiping Zhu
    Wanxia Huang
    Qingxi Yuan
    Xiaosong Liu
    Kai Zhang
    Youli Hong
    Huitao Zhang
    Xin Ge
    Kun Gao
    Ziyu Wu
    Analytical and Bioanalytical Chemistry, 2010, 397 : 2137 - 2141
  • [30] DEMONSTRATION OF PHASE-CONTRAST X-RAY COMPUTED-TOMOGRAPHY USING AN X-RAY INTERFEROMETER
    MOMOSE, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 352 (03): : 622 - 628