Influence of laser parameters on isotope fractionation and optimisation of lithium and boron isotope ratio measurements using laser ablation-multiple Faraday collector-inductively coupled plasma mass spectrometry

被引:31
|
作者
Kimura, Jun-ichi [1 ]
Chang, Qing [1 ]
Ishikawa, Tsuyoshi [2 ]
Tsujimori, Tatsuki [3 ]
机构
[1] Japan Agcy Marine Earth Sci & Technol JAMSTEC, Dept Solid Earth Geochem, 2-15 Natsushima Cho, Yokosuka, Kanagawa 2370061, Japan
[2] Japan Agcy Marine Earth Sci & Technol JAMSTEC, Kochi Inst Core Sample Res, 200 Monobe Otsu, Nankoku, Kochi 7838502, Japan
[3] Tohoku Univ, Ctr Northeast Asian Studies, Aoba Ku, 41 Kawauchi, Sendai, Miyagi 9808576, Japan
关键词
UV-FEMTOSECOND LASER; ICP-MS; IN-SITU; ULTRAVIOLET FEMTOSECOND; GLASS; MINERALS; ROCKS; SYSTEMATICS; DELTA-B-11; SAMPLES;
D O I
10.1039/c6ja00283h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report the origin of isotope fractionation induced by the choice of laser parameters and a method for accurate in situ determination of lithium (delta Li-7) and boron (delta B-11) isotope ratios in glasses and minerals using laser ablation multiple Faraday collector inductively coupled plasma mass spectrometry (LA-MFC-ICPMS). Laser ablation parameters were examined using 266 nm femtosecond (266FsLA) and 193 nm nanosecond excimer (193ExLA) laser ablation systems for crater diameters of 30-200 mu m. We found that higher laser repetition rates and larger crater diameters have led to enhanced fractionation of lighter isotopes, as much as -8 parts per thousand for both delta Li-7 and delta B-11. Fractionation was primarily affected by the ICP aerosol loading and secondly by the thermal fractionation at the LA site. The former was accounted for by mass loading effects, which lowered the plasma temperature and led to insufficient aerosol vaporisation. The latter was related to the molten layer on the crater walls, which resulted in coarser and heavier delta Li-7 and delta B-11 aerosols that did not reach the ICP. Both processes can result in Rayleigh fractionation during aerosol formation and vaporisation. Controlled ablation using a constant crater size, repetition rate, and high laser fluence of 193ExLA enabled reproducible ablation for the standard NIST SRM 61X glasses and unknown basalt glasses. Based on the principles of isotopic fractionation deduced from our experiments, we propose a novel ablation volume correction (AVC) protocol for accurate isotopic analyses of various samples with different matrices. Both the repeatability and the laboratory bias of the delta Li-7 and delta B-11 measurements using the new AVC protocol were better than 1 parts per thousand for samples containing a few tens to a few tens of thousands ppm Li and B. We also report significant local heterogeneity of up to several parts per thousand found in some basalt glasses, but not in NIST SRM 612 and 610.
引用
收藏
页码:2305 / 2320
页数:16
相关论文
共 50 条
  • [1] Pb isotope analyses of silicate rocks and minerals with Faraday detectors using enhanced-sensitivity laser ablation-multiple collector-inductively coupled plasma mass spectrometry
    Kimura, Jun-ichi
    Kawabata, Hiroshi
    Chang, Qing
    Miyazaki, Takashi
    Hanyu, Takeshi
    [J]. GEOCHEMICAL JOURNAL, 2013, 47 (03) : 369 - 384
  • [2] In situ S isotopic analysis in apatite using laser ablation-multiple collector-inductively coupled plasma mass spectrometry
    Li, Qinglin
    Zhang, Wen
    Hu, Zhaochu
    Feng, Yantong
    Hu, Hao
    Luo, Tao
    Huang, Jing
    Zeng, Xianli
    [J]. CHEMICAL GEOLOGY, 2023, 636
  • [3] Isotopic analysis of zirconium using enhanced sensitivity-laser ablation-multiple collector-inductively coupled plasma mass spectrometry
    Hirata, T
    Yamaguchi, T
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) : 1455 - 1459
  • [4] Sulfur isotope fractionation in pyrite during laser ablation: Implications for laser ablation multiple collector inductively coupled plasma mass spectrometry mapping
    Zhu, Zhi-Yong
    Jiang, Shao-Yong
    Ciobanu, Cristiana L.
    Yang, Tao
    Cook, Nigel J.
    [J]. CHEMICAL GEOLOGY, 2017, 450 : 223 - 234
  • [5] Silicon isotope measurement in zircon by laser ablation multiple collector inductively coupled plasma mass spectrometry
    Guitreau, Martin
    Gannoun, Abdelmouhcine
    Deng, Zhengbin
    Marin-Carbonne, Johanna
    Chaussidon, Marc
    Moynier, Frederic
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (08) : 1597 - 1606
  • [6] In-situ osmium isotope ratio analyses of iridosmines by laser ablation multiple collector inductively coupled plasma mass spectrometry
    Hirata, T
    Hattori, M
    Tanaka, T
    [J]. CHEMICAL GEOLOGY, 1998, 144 (3-4) : 269 - 280
  • [7] Laser ablation inductively coupled plasma mass spectrometry for direct isotope ratio measurements on solid samples
    Pickhardt, C
    Dietze, HJ
    Becker, JS
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 242 (2-3) : 273 - 280
  • [8] Isotope ratio determination by laser ablation-single collector-inductively coupled plasma-mass spectrometry. General capabilities and possibilities for improvement
    Aramendia, Maite
    Resano, Martin
    Vanhaecke, Frank
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (03) : 390 - 404
  • [10] High precision measurement of germanium isotope ratio variations by multiple collector-inductively coupled plasma mass spectrometry
    Galy, A
    Pomiès, C
    Day, JA
    Pokrovsky, OS
    Schott, J
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (02) : 115 - 119