Time-Resolved Interventional Cardiac C-arm Cone-Beam CT: An Application of the PICCS Algorithm

被引:70
|
作者
Chen, Guang-Hong [1 ]
Theriault-Lauzier, Pascal [1 ]
Tang, Jie [1 ]
Nett, Brian [1 ]
Leng, Shuai [1 ]
Zambelli, Joseph [1 ]
Qi, Zhihua [1 ]
Bevins, Nicholas [1 ]
Raval, Amish [2 ]
Reeder, Scott [3 ]
Rowley, Howard [3 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53792 USA
[2] Univ Wisconsin, Dept Med, Madison, WI 53792 USA
[3] Univ Wisconsin, Dept Radiol, Madison, WI 53792 USA
基金
加拿大自然科学与工程研究理事会; 美国国家卫生研究院;
关键词
Cardiac cone-beam CT; compressed sensing; high temporal resolution; interventional imaging; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; IMAGE-RECONSTRUCTION; LEFT ATRIUM; TEMPORAL RESOLUTION; CATHETER ABLATION; PULMONARY VEINS; ANGIOGRAPHY; PERFORMANCE; ESOPHAGUS;
D O I
10.1109/TMI.2011.2172951
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Time-resolved cardiac imaging is particularly interesting in the interventional setting since it would provide both image guidance for accurate procedural planning and cardiac functional evaluations directly in the operating room. Imaging the heart in vivo using a slowly rotating C-arm system is extremely challenging due to the limitations of the data acquisition system and the high temporal resolution required to avoid motion artifacts. In this paper, a data acquisition scheme and an image reconstruction method are proposed to achieve time-resolved cardiac cone-beam computed tomography imaging with isotropic spatial resolution and high temporal resolution using a slowly rotating C-arm system. The data are acquired within 14 s using a single gantry rotation with a short scan angular range. The enabling image reconstruction method is the prior image constrained compressed sensing (PICCS) algorithm. The prior image is reconstructed from data acquired over all cardiac phases. Each cardiac phase is then reconstructed from the retrospectively gated cardiac data using the PICCS algorithm. To validate the method, several studies were performed. Both numerical simulations using a hybrid motion phantom with static background anatomy as well as physical phantom studies have been used to demonstrate that the proposed method enables accurate reconstruction of image objects with a high isotropic spatial resolution. A canine animal model scanned in vivo was used to further validate the method.
引用
收藏
页码:907 / 923
页数:17
相关论文
共 50 条
  • [31] GPU based parallel acceleration for fast C-arm cone-beam CT reconstruction
    Chen, Ken
    Wang, Cheng
    Xiong, Jing
    Xie, Yaoqin
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [32] Tomosynthesis and cone-beam CT on a mobile C-arm for image-guided interventions
    Daly, M.
    Siewerdsen, J.
    Bachar, G.
    Moseley, D.
    Chhabra, S.
    Jaffray, D.
    Irish, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2624 - 2625
  • [33] Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance
    Schafer, S.
    Nithiananthan, S.
    Mirota, D. J.
    Uneri, A.
    Stayman, J. W.
    Zbijewski, W.
    Schmidgunst, C.
    Kleinszig, G.
    Khanna, A. J.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2011, 38 (08) : 4563 - 4574
  • [34] Erratum to: C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications
    Chiara Floridi
    Alessandro Radaelli
    Nadine Abi-Jaoudeh
    Michael Grass
    MingDe Lin
    Melanie Chiaradia
    Jean-Francois Geschwind
    Hicham Kobeiter
    Ettore Squillaci
    Geert Maleux
    Andrea Giovagnoni
    Luca Brunese
    Bradford Wood
    Gianpaolo Carrafiello
    Antonio Rotondo
    La radiologia medica, 2015, 120 : 406 - 406
  • [35] Evaluation of Patient Effective Dose of Neurovascular Imaging Protocols for C-Arm Cone-Beam CT
    Wang, Chu
    Nguyen, Giao
    Toncheva, Greta
    Jiang, Xianxian
    Ferrell, Andrew
    Smith, Tony
    Yoshizumi, Terry
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (05) : 1072 - 1077
  • [37] A mechanical solution for patient positioning using cone-beam CT acquired with a mobile C-arm
    Sorensen, S
    Mitschke, M
    Chow, P
    Wink, N
    Medin, P
    Solberg, T
    MEDICAL PHYSICS, 2004, 31 (06) : 1856 - 1856
  • [38] Accelerated statistical reconstruction for C-arm cone-beam CT using Nesterov's method
    Wang, Adam S.
    Stayman, J. Webster
    Otake, Yoshito
    Vogt, Sebastian
    Kleinszig, Gerhard
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2015, 42 (05) : 2699 - 2708
  • [39] Antiscatter grids in mobile C-arm cone-beam CT: Effect on image quality and dose
    Schafer, S.
    Stayman, J. W.
    Zbijewski, W.
    Schmidgunst, C.
    Kleinszig, G.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2012, 39 (01) : 153 - 159
  • [40] Application of a Metal Artifact Reduction Algorithm for C-Arm Cone-Beam CT: Impact on Image Quality and Diagnostic Confidence for Bronchial Artery Embolization
    Estler, Arne
    Bongers, Malte
    Thomas, Christoph
    Hefferman, Gerald
    Hofmann, Johannes
    Hoffmann, Ruediger
    Nikolaou, Konstantin
    Grosse, Ulrich
    Groezinger, Gerd
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2019, 42 (10) : 1449 - 1458