Stand-Alone Heartbeat Detection in Multidimensional Mechanocardiograms

被引:38
|
作者
Kaisti, Matti [1 ]
Tadi, Mojtaba Jafari [1 ]
Landenoja, Olli [1 ]
Hurnanen, Tero [1 ]
Saraste, Antti [2 ,3 ]
Pankaala, Mikko [1 ]
Koivisto, Tero [1 ]
机构
[1] Univ Turku, Fac Sci & Engn, Dept Future Technol, SF-20500 Turku, Finland
[2] Turku Univ Hosp, Heart Ctr, Turku 20521, Finland
[3] Turku Univ Hosp, PET Ctr, Turku 20521, Finland
基金
芬兰科学院;
关键词
Sensor fusion; beat-to-beat detection; wearable technology; accelerometer; gyroscope; seismocardiography; mechanocardiography; BEAT; SEISMOCARDIOGRAM; ALGORITHM; SENSOR; SLEEP;
D O I
10.1109/JSEN.2018.2874706
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We describe a home health monitoring solution with cardiac beat-to-beat detection using accelerometer and gyroscope signal fusion. The proposed method measures both the precordial translational and rotational motions of the chest using miniaturized inertial sensors. The algorithm removes motion artefacts, selects the best axis from multi-axial accelerometric and gyroscopic signals and detects the location of beats using two detection principles based on the signal envelope and signal morphology. We consider the beat-to-heat detection accuracy, estimate the heart rate and compare the detection performance between the sensor modalities in two study groups: i) healthy subjects and ii) heart disease patients. The average sensitivity and precision of the beat detection were 99.9% and 99.6% for the healthy subjects and 96.1% and 95.6% for the heart disease patients, respectively. Although high-accuracy beat detection was achieved for the heart disease patients, location matching in these patients was found to be less accurate compared to that of the healthy subjects. The average root mean square error (RMSE) between the mechanical and ECG interbeat intervals was 5.6 ms for the healthy patients; this error increased approximately 10-fold for the heart disease patients. Similarly, the RMSE for the averaged heart rate estimation showed about a 10-fold difference at 1.05 beats per minute for the heart disease patients. The used sensor modalities are found in many electronic devices, such as smartphones and wearable technologies and this method provides a step towards ubiquitous cardiac monitoring.
引用
收藏
页码:234 / 242
页数:9
相关论文
共 50 条
  • [41] A Stand-Alone Fracture Monitoring System
    Morales-Ramos, R.
    Sosa, J.
    Montiel-Nelson, J. A.
    Nooshabadi, S.
    Zwick, A.
    Nguyen, X. P.
    2011 IEEE 54TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2011,
  • [42] A STAND-ALONE IN-CIRCUIT EMULATOR
    ERGINCAN, F
    SAATCI, A
    MICROPROCESSING AND MICROPROGRAMMING, 1986, 17 (03): : 159 - 167
  • [43] A TRIAL OF STAND-ALONE WORD PROCESSORS
    BALDWINSMITH, EL
    MANAGEMENT SERVICES IN GOVERNMENT, 1980, 35 (02): : 83 - 87
  • [44] Use of cervical stand-alone cages
    Börm, W
    Seitz, K
    EUROPEAN SPINE JOURNAL, 2004, 13 (05) : 474 - 475
  • [45] HYBRID SYSTEM FOR A STAND-ALONE APPLICATION
    Jaliu, C.
    Saulescu, R.
    Ciobanu, D.
    2016 INTERNATIONAL CONFERENCE ON PRODUCTION RESEARCH - REGIONAL CONFERENCE AFRICA, EUROPE AND THE MIDDLE EAST (ICPR-AEM 2016) AND 4TH INTERNATIONAL CONFERENCE ON QUALITY AND INNOVATION IN ENGINEERING AND MANAGEMENT (QIEM 2016), 2016, : 124 - 129
  • [46] A Framework for Developing Stand-Alone Certifiers
    Sternagel, Christian
    Thiemann, Rene
    ELECTRONIC NOTES IN THEORETICAL COMPUTER SCIENCE, 2015, 312 : 51 - 67
  • [47] Stand-alone tsunami alarm equipment
    Katsumata, Akio
    Hayashi, Yutaka
    Miyaoka, Kazuki
    Tsushima, Hiroaki
    Baba, Toshitaka
    Catalan, Patricio A.
    Zelaya, Cecilia
    Riquelme Vasquez, Felipe
    Sanchez-Olavarria, Rodrigo
    Barrientos, Sergio
    NATURAL HAZARDS AND EARTH SYSTEM SCIENCES, 2017, 17 (05) : 685 - 692
  • [48] Research now a stand-alone business
    Powell, Michael
    Railway Gazette International, 1991, 147 (04)
  • [49] PAPERBACK SPELLER - A STAND-ALONE PACKAGE
    YERKEY, N
    ELECTRONIC LIBRARY, 1987, 5 (01): : 24 - 25
  • [50] DIAGNOSTIC TECHNIQUES WITH STAND-ALONE CAPABILITY
    READ, AH
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (05): : 695 - 696