Stand-Alone Heartbeat Detection in Multidimensional Mechanocardiograms

被引:38
|
作者
Kaisti, Matti [1 ]
Tadi, Mojtaba Jafari [1 ]
Landenoja, Olli [1 ]
Hurnanen, Tero [1 ]
Saraste, Antti [2 ,3 ]
Pankaala, Mikko [1 ]
Koivisto, Tero [1 ]
机构
[1] Univ Turku, Fac Sci & Engn, Dept Future Technol, SF-20500 Turku, Finland
[2] Turku Univ Hosp, Heart Ctr, Turku 20521, Finland
[3] Turku Univ Hosp, PET Ctr, Turku 20521, Finland
基金
芬兰科学院;
关键词
Sensor fusion; beat-to-beat detection; wearable technology; accelerometer; gyroscope; seismocardiography; mechanocardiography; BEAT; SEISMOCARDIOGRAM; ALGORITHM; SENSOR; SLEEP;
D O I
10.1109/JSEN.2018.2874706
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We describe a home health monitoring solution with cardiac beat-to-beat detection using accelerometer and gyroscope signal fusion. The proposed method measures both the precordial translational and rotational motions of the chest using miniaturized inertial sensors. The algorithm removes motion artefacts, selects the best axis from multi-axial accelerometric and gyroscopic signals and detects the location of beats using two detection principles based on the signal envelope and signal morphology. We consider the beat-to-heat detection accuracy, estimate the heart rate and compare the detection performance between the sensor modalities in two study groups: i) healthy subjects and ii) heart disease patients. The average sensitivity and precision of the beat detection were 99.9% and 99.6% for the healthy subjects and 96.1% and 95.6% for the heart disease patients, respectively. Although high-accuracy beat detection was achieved for the heart disease patients, location matching in these patients was found to be less accurate compared to that of the healthy subjects. The average root mean square error (RMSE) between the mechanical and ECG interbeat intervals was 5.6 ms for the healthy patients; this error increased approximately 10-fold for the heart disease patients. Similarly, the RMSE for the averaged heart rate estimation showed about a 10-fold difference at 1.05 beats per minute for the heart disease patients. The used sensor modalities are found in many electronic devices, such as smartphones and wearable technologies and this method provides a step towards ubiquitous cardiac monitoring.
引用
收藏
页码:234 / 242
页数:9
相关论文
共 50 条
  • [21] MIMS is not a stand-alone resource
    Donohoo, Elizabeth A.
    MEDICAL JOURNAL OF AUSTRALIA, 2007, 186 (09) : 484 - 484
  • [22] Stand-alone and network capable pocket radiation detection system
    Aryaeinejad, R.
    Spencer, D. F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 600 (03): : 604 - 608
  • [23] Compatibility and bundling of stand and No stand-alone use complements
    Vamosiu, Adriana
    INTERNATIONAL JOURNAL OF PRODUCTION ECONOMICS, 2018, 201 : 62 - 74
  • [24] A comparison between stand-alone and distributed architectures for spectrum hole detection
    Bixio, Luca
    Ottonello, Marina
    Raffetto, Mirco
    Regazzoni, Carlo S.
    2010 IEEE WIRELESS COMMUNICATIONS AND NETWORKING CONFERENCE (WCNC 2010), 2010,
  • [25] Grid reconnection detection for synchronous distributed generators in stand-alone operation
    Jouybari-Moghaddam, Hessamoddin
    Hosseinian, Seyed Hossein
    Vahidi, Behrooz
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2015, 25 (01): : 138 - 154
  • [26] A STAND-ALONE MEASUREMENT PLOTTING SYSTEM
    DANIELS, TH
    FENOGLIO, JA
    HEWLETT-PACKARD JOURNAL, 1986, 37 (01): : 20 - 24
  • [27] STAND-ALONE THERMAL DESALINATION PLANTS
    RIFERT, VG
    BARABASH, PA
    GOLIYAD, NN
    KURILOVA, EB
    DESALINATION, 1994, 96 (1-3) : 183 - 190
  • [28] Stand-Alone Electronic Health Record
    Duarte, Julio
    Pontes, Gabriel
    Salazar, Maria
    Santos, Manuel
    Abelha, Antonio
    Machado, Jose
    2013 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND ENGINEERING MANAGEMENT (IEEM 2013), 2013, : 1052 - 1056
  • [29] Decontextualization: Making Sentences Stand-Alone
    Choi, Eunsol
    Palomaki, Jennimaria
    Lamm, Matthew
    Kwiatkowski, Tom
    Das, Dipanjan
    Collins, Michael
    TRANSACTIONS OF THE ASSOCIATION FOR COMPUTATIONAL LINGUISTICS, 2021, 9 : 447 - 461
  • [30] Use of cervical stand-alone cages
    Wolfgang Börm
    Klaus Seitz
    European Spine Journal, 2004, 13 : 474 - 475