COMPARISON OF TWO ANTHROPOMORPHIC PHANTOMS AS A CALIBRATION TOOL FOR WHOLE-BODY COUNTER USING MONTE CARLO SIMULATIONS

被引:1
|
作者
Manohari, M. [1 ]
Mathiyarasu, R. [1 ]
Rajagopal, V. [1 ]
Venkatraman, B. [1 ]
机构
[1] Indira Gandhi Ctr Atom Res, Radiol Safety Div, Elect Instrumentat & Radiol Safety Grp, Kalpakkam 60312, Tamil Nadu, India
关键词
BOMAB PHANTOM; DETECTOR;
D O I
10.1093/rpd/ncu287
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The whole-body counting facility at the Indira Gandhi Centre for Atomic Research uses an in-house built Masonite cut-sheet phantom for the calibration of whole-body monitors. Recently, an Indian Adult BOMAB phantom was procured as an additional utility to augment the facility. The present study is to generate full-energy peak efficiencies (FEPE) of the shielded chair (SC) whole-body counting system using the new BOMAB phantom through Monte Carlo (MC) simulations. The values are compared with that of the Masonite phantom. First, the SC was modelled along with the Masonite phantom to estimate the FEPE values and Compton scattering factors (CSFs) for different energies. The simulated values were validated against the measurements using the Masonite cut-sheet phantom (Masonite phantom). The validated SC model was used along with the Indian adult BOMAB phantom to estimate the FEPEs and the CSFs. The simulated BOMAB phantom values were compared with the simulated Masonite phantom values. The maximum deviation for both the FEPEs and CSFs was +/- 10 % validating the use of the Masonite phantom as a calibration tool representing an Indian adult.
引用
收藏
页码:298 / 303
页数:6
相关论文
共 50 条
  • [1] Application of voxel phantoms and Monte Carlo method to whole-body counter calibration
    Kinase, S.
    Takagi, S.
    Noguchi, H.
    Saito, K.
    [J]. RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 189 - 193
  • [2] MONTE CARLO SIMULATION OF A WHOLE-BODY COUNTER USING IGOR PHANTOMS
    Bochud, Francois O.
    Laedermann, Jean-Pascal
    Baechler, Sebastien
    Bailat, Claude J.
    Boschung, Markus
    Aroua, Abbas
    Mayer, Sabine
    [J]. RADIATION PROTECTION DOSIMETRY, 2014, 162 (03) : 280 - 288
  • [3] A MONTE CARLO CALIBRATION OF A WHOLE BODY COUNTER USING THE ICRP COMPUTATIONAL PHANTOMS
    Nilsson, Jenny
    Isaksson, Mats
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 163 (04) : 458 - 467
  • [4] Monte-Carlo simulations with mathematical phantoms to investigate the effectiveness of a whole-body counter for thyroid measurement
    Tani, Kotaro
    Igarashi, Yu
    Kim, Eunjoo
    Iimoto, Takeshi
    Kurihara, Osamu
    [J]. RADIATION MEASUREMENTS, 2020, 135
  • [5] EVALUATION OF COUNTING EFFICIENCIES OF A WHOLE-BODY COUNTER USING MONTE CARLO SIMULATION WITH VOXEL PHANTOMS
    Takahashi, Masa
    Kinase, Sakae
    Kramer, Richard
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 407 - 410
  • [6] Monte Carlo calculations for efficiency calibration of a whole-body monitor using BOMAB phantoms of different sizes
    Bhati, S.
    Patni, H. K.
    Ghare, V. P.
    Singh, I. S.
    Nadar, M. Y.
    [J]. RADIATION PROTECTION DOSIMETRY, 2012, 148 (04) : 414 - 419
  • [7] STANDARDIZATION OF CALIBRATION METHOD OF WHOLE-BODY COUNTER .1. CALIBRATION BY USING ANTHROPOMETRIC PHANTOMS
    ISHIKAWA, T
    MATSUMOTO, M
    UCHIYAMA, M
    MIZUSHITA, S
    KOBAYASHI, S
    [J]. JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1995, 37 (05): : 420 - 429
  • [8] Monte Carlo simulations of vehicle-mounted whole-body NaI(Tl) counter
    Mo, H.
    Gong, P.
    Liang, D.
    Wang, Z.
    Zhang, J.
    Hu, Z.
    Wu, R.
    Tang, X.
    Wang, J.
    Ma, J.
    Yang, X.
    [J]. JOURNAL OF INSTRUMENTATION, 2022, 17 (09)
  • [9] A calibration method for whole-body counters, using Monte Carlo simulation
    Ishikawa, T
    Matsumoto, M
    Uchiyama, M
    [J]. RADIATION PROTECTION DOSIMETRY, 1996, 64 (04) : 283 - 288
  • [10] Virtual calibration of whole-body counters to consider the size dependency of counting efficiency using Monte Carlo simulations
    Park, MinSeok
    Kim, Han Sung
    Yoo, Jaeryong
    Kim, Chan Hyeong
    Jang, Won Il
    Park, Sunhoo
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (12) : 4122 - 4129