A calibration method for whole-body counters, using Monte Carlo simulation

被引:14
|
作者
Ishikawa, T
Matsumoto, M
Uchiyama, M
机构
[1] Natl. Inst. of Radiological Sciences, Inage-ku, Chiba, 263
关键词
D O I
10.1093/oxfordjournals.rpd.a031585
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A Monte Carlo simulation code was developed to estimate the counting efficiencies in whole-body counting for various body sizes. The code consists of mathematical models and parameters which are categorised into three groups: a geometrical model for phantoms and detectors, a photon transport model, and a detection system model. Photon histories were simulated with these models. The counting efficiencies for five Cs-137 block phantoms of different sizes were calculated by the code and compared with those measured with a whole-body counter at NIRS (Japan). The phantoms corresponded to a newborn, a 5 month old, a 6 year old, an 11 year old and an adult. The differences between the measured and calculated values were within 6%. For the adult phantom, the difference was 0.5%. The results suggest that the Monte Carlo simulation code can be used to estimate the counting efficiencies for various body sizes.
引用
收藏
页码:283 / 288
页数:6
相关论文
共 50 条
  • [1] Monte Carlo calibration of whole-body counters with NaI(Tl) detectors in stretcher geometry
    Breustedt, B.
    Eschner, W.
    [J]. RADIATION PROTECTION DOSIMETRY, 2010, 139 (04) : 510 - 518
  • [2] Virtual calibration of whole-body counters to consider the size dependency of counting efficiency using Monte Carlo simulations
    Park, MinSeok
    Kim, Han Sung
    Yoo, Jaeryong
    Kim, Chan Hyeong
    Jang, Won Il
    Park, Sunhoo
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (12) : 4122 - 4129
  • [3] Application of voxel phantoms and Monte Carlo method to whole-body counter calibration
    Kinase, S.
    Takagi, S.
    Noguchi, H.
    Saito, K.
    [J]. RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 189 - 193
  • [4] MONTE CARLO SIMULATION OF A WHOLE-BODY COUNTER USING IGOR PHANTOMS
    Bochud, Francois O.
    Laedermann, Jean-Pascal
    Baechler, Sebastien
    Bailat, Claude J.
    Boschung, Markus
    Aroua, Abbas
    Mayer, Sabine
    [J]. RADIATION PROTECTION DOSIMETRY, 2014, 162 (03) : 280 - 288
  • [5] INTERCOMPARISON OF WHOLE-BODY COUNTERS USING A MULTINUCLIDE CALIBRATION PHANTOM
    FENWICK, JD
    MCKENZIE, AL
    BODDY, K
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (02): : 191 - 198
  • [6] Calibration of a whole body counter using Monte Carlo methods
    Breustedt, Bastian
    Schieck, Hans Paetz Gen
    Schicha, Harald
    Eschner, Wolfgang
    [J]. Zeitschrift fur Medizinische Physik, 2004, 14 (02): : 85 - 94
  • [7] WHOLE-BODY COUNTERS
    REMENCHI.AP
    MILLER, CE
    [J]. JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1966, 197 (01): : 47 - &
  • [8] COMPARISON OF TWO ANTHROPOMORPHIC PHANTOMS AS A CALIBRATION TOOL FOR WHOLE-BODY COUNTER USING MONTE CARLO SIMULATIONS
    Manohari, M.
    Mathiyarasu, R.
    Rajagopal, V.
    Venkatraman, B.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 164 (03) : 298 - 303
  • [9] Monte Carlo calculations for efficiency calibration of a whole-body monitor using BOMAB phantoms of different sizes
    Bhati, S.
    Patni, H. K.
    Ghare, V. P.
    Singh, I. S.
    Nadar, M. Y.
    [J]. RADIATION PROTECTION DOSIMETRY, 2012, 148 (04) : 414 - 419
  • [10] EVALUATION OF COUNTING EFFICIENCIES OF A WHOLE-BODY COUNTER USING MONTE CARLO SIMULATION WITH VOXEL PHANTOMS
    Takahashi, Masa
    Kinase, Sakae
    Kramer, Richard
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 407 - 410