Monte-Carlo simulations with mathematical phantoms to investigate the effectiveness of a whole-body counter for thyroid measurement

被引:4
|
作者
Tani, Kotaro [1 ]
Igarashi, Yu [1 ,2 ]
Kim, Eunjoo [1 ]
Iimoto, Takeshi [2 ]
Kurihara, Osamu [1 ]
机构
[1] Natl Inst Quantum & Radiol Sci & Technol, Dept Radiat Measurement & Dose Assessment, Inage Ku, 4-9-1 Anagawa, Chiba 2638555, Japan
[2] Univ Tokyo, Dept Environm Syst, 5-1-5 Kashiwanoha, Kashiwa, Chiba 2778563, Japan
关键词
Internal contamination; I-131; Thyroid measurement; Whole-body counter; FUKUSHIMA;
D O I
10.1016/j.radmeas.2020.106335
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
FASTSCAN (Canberra, Meriden, CT, USA), a standing-type whole-body counter with upper and lower NaI(Tl) detectors, has been mostly used to determine local residents' level of internal contamination with (CS)-C-134/137 following the Fukushima Daiichi Nuclear Power Plant (FDNPP) disaster in 2011. In the present study, we performed Monte-Carlo simulations with age-specific mathematical human phantoms to investigate the counting efficiencies of the FASTSCAN counter for I-131 thyroid measurements. As a result, although the lower detector had low sensitivity for I-131 in the thyroids of the adult and 15 y phantoms as well as the 10 y phantom standing on a 30-cm-high stool, the response of this detector may be used as an indicator of surface contamination overlooked on a subject. The total counting efficiency investigated in this study was 0.017-0.018 (cps/Bq) among all age groups. Based on this sensitivity, the determination level for thyroid activity could be calculated to be similar to 300 Bq under the slightly elevated background radiation level observed after the FDNPP disaster.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] MONTE CARLO SIMULATION OF A WHOLE-BODY COUNTER USING IGOR PHANTOMS
    Bochud, Francois O.
    Laedermann, Jean-Pascal
    Baechler, Sebastien
    Bailat, Claude J.
    Boschung, Markus
    Aroua, Abbas
    Mayer, Sabine
    [J]. RADIATION PROTECTION DOSIMETRY, 2014, 162 (03) : 280 - 288
  • [2] COMPARISON OF TWO ANTHROPOMORPHIC PHANTOMS AS A CALIBRATION TOOL FOR WHOLE-BODY COUNTER USING MONTE CARLO SIMULATIONS
    Manohari, M.
    Mathiyarasu, R.
    Rajagopal, V.
    Venkatraman, B.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 164 (03) : 298 - 303
  • [3] Application of voxel phantoms and Monte Carlo method to whole-body counter calibration
    Kinase, S.
    Takagi, S.
    Noguchi, H.
    Saito, K.
    [J]. RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 189 - 193
  • [4] EVALUATION OF COUNTING EFFICIENCIES OF A WHOLE-BODY COUNTER USING MONTE CARLO SIMULATION WITH VOXEL PHANTOMS
    Takahashi, Masa
    Kinase, Sakae
    Kramer, Richard
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 407 - 410
  • [5] Monte Carlo simulations of vehicle-mounted whole-body NaI(Tl) counter
    Mo, H.
    Gong, P.
    Liang, D.
    Wang, Z.
    Zhang, J.
    Hu, Z.
    Wu, R.
    Tang, X.
    Wang, J.
    Ma, J.
    Yang, X.
    [J]. JOURNAL OF INSTRUMENTATION, 2022, 17 (09)
  • [6] A MONTE CARLO CALIBRATION OF A WHOLE BODY COUNTER USING THE ICRP COMPUTATIONAL PHANTOMS
    Nilsson, Jenny
    Isaksson, Mats
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 163 (04) : 458 - 467
  • [7] Monte Carlo calculation of whole body counter efficiency factors for different computational phantoms
    Ferreira, Carlos V. G.
    Piedade, Jennifer S.
    Prado, Max R. D.
    Benavente, Jhonny
    Mendes, Bruno M.
    Paixao, Lucas
    Fonseca, Telma C. F.
    [J]. APPLIED RADIATION AND ISOTOPES, 2023, 194
  • [8] Monte Carlo simulations of the whole-body counter at Spiez Laboratory Switzerland: Impact of phantom size and biokinetic model
    Desorgher, Laurent
    Mosimann, Nina
    Althaus, Rolf
    Wirz, Christoph
    Bailat, Claude
    Medici, Siria
    Bochud, Francois
    [J]. RADIATION MEASUREMENTS, 2022, 152
  • [9] RESULTS ON MONTE-CARLO SIMULATIONS OF A MICROSTRIP GAS COUNTER
    SCHMITZ, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 323 (03): : 638 - 644
  • [10] Monte Carlo calculations for efficiency calibration of a whole-body monitor using BOMAB phantoms of different sizes
    Bhati, S.
    Patni, H. K.
    Ghare, V. P.
    Singh, I. S.
    Nadar, M. Y.
    [J]. RADIATION PROTECTION DOSIMETRY, 2012, 148 (04) : 414 - 419