Validation of a micro-CT technique for measuring volumetric wear in retrieved acetabular liners

被引:27
|
作者
Bowden, AE [1 ]
Kurtz, SM
Edidin, AA
机构
[1] Drexel Univ, Implant Res Ctr, Philadelphia, PA 19104 USA
[2] Exponent Inc, Philadelphia, PA USA
关键词
polyethylene; wear; retrieval; microCT; registration;
D O I
10.1002/jbm.b.30318
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, a novel micro-CT-based technique for evaluating wear in retrieved acetabular liners was introduced and validated. Six UHMWPE acetabular components ranging in implantation time from 2.7 to 14.4 years were collected and evaluated with the use of a high-resolution micro-CT scanner. The components were scanned with a uniform volumetric resolution of 74 microns (16-bit precision) with the use of a 1024 X 1024 in-plane image matrix. Manual rigid 3D image registration of the interior hemispherical portion of the acetabular cup with geometric primitives by trained observers allowed for isolation, visualization, and measurement of the wear volume. Results for these six components indicated an average wear rate of 65 mm(3)/year. Overall scanner error was quantified gravimetrically and associated with a maximum uncertainty of 0.6%. Intra- and interobserver uncertainty analysis showed the method to be both accurate and repeatable. (c) 2005 Wiley Periodicals, Inc.
引用
收藏
页码:205 / 209
页数:5
相关论文
共 50 条
  • [1] Backside wear is low in retrieved modern, modular, and nonmodular acetabular liners
    Della Valle, AG
    Rana, A
    Furman, B
    Sculco, TP
    Salvati, EA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) : 184 - 191
  • [2] Highly Crosslinked Polyethylene Improves Wear But Not Surface Damage in Retrieved Acetabular Liners
    Pang, Hee-Nee
    Naudie, Douglas D. R.
    McCalden, Richard W.
    MacDonald, Steven J.
    Teeter, Matthew G.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (02) : 463 - 468
  • [3] Technique to quantify subsurface cracks in retrieved polyethylene components using micro-CT
    Teeter M.G.
    Yuan X.
    Naudie D.D.R.
    Holdsworth D.W.
    Journal of Long-Term Effects of Medical Implants, 2010, 20 (01) : 27 - 34
  • [4] Surface topography of retrieved PCA acetabular liners: proposal of a novel wear mechanism
    Elfick, AP
    Hall, RM
    Unsworth, A
    Pinder, IM
    JOURNAL OF MATERIALS SCIENCE LETTERS, 1998, 17 (13) : 1085 - 1088
  • [5] Relationship of surface damage appearance and volumetric wear in retrieved TKR polyethylene liners
    Knowlton, Christopher B.
    Bhutani, Priyanka
    Wimmer, Markus A.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2017, 105 (07) : 2053 - 2059
  • [6] Volumetric micro-CT system for in vivo microscopy
    Badea, CT
    Hedlund, LW
    Wheeler, CT
    Mai, W
    Johnson, GA
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 1377 - 1380
  • [7] Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners
    Bradford, L
    Baker, DA
    Graham, J
    Chawan, A
    Ries, MD
    Pruitt, LA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (06): : 1271 - 1282
  • [8] Dual mobility retentive acetabular liners and wear: Surface analysis of 40 retrieved polyethylene implants
    Adam, P.
    Farizon, F.
    Fessy, M. -H.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (01) : 85 - 91
  • [9] Retrieved Highly Crosslinked UHMWPE Acetabular Liners Have Similar Wear Damage as Conventional UHMWPE
    Schroder, David T.
    Kelly, Natalie H.
    Wright, Timothy M.
    Parks, Michael L.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) : 387 - 394
  • [10] Dual articulation retentive acetabular liners and wear: surface analysis of 40 retrieved polyethylene implants
    Adam, P
    Farizon, F
    Fessy, MH
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2005, 91 (07): : 627 - 636