Laboratory and field testing of sampling methods for inhalable and respirable dust

被引:19
|
作者
Linnainmaa, Markku [1 ]
Laitinen, Juha [1 ]
Leskinen, Ari [2 ]
Sippula, Olli [3 ]
Kalliokoski, Pentti [3 ]
机构
[1] Finnish Inst Occupat Hlth, FI-70701 Kuopio, Finland
[2] Finnish Meteorol Inst, Kuopio Unit, Kuopio, Finland
[3] Univ Kuopio, FIN-70211 Kuopio, Finland
关键词
aerosol monitoring; cascade impactor; inhalable dust; IOM samplers; particle size-selective sampling; respirable dust;
D O I
10.1080/15459620701763723
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The performance of four sampling devices for inhalable dust and three devices for respirable dust was tested with different kinds of dusts in the laboratory and in the field. The IOM sampler was chosen as the reference method for inhalable dust, and the IOM sampler provided with the porous plastic foam media was used as the reference method for respirable dust. The other tested instruments were the Button sampler, the optical Grimm aerosol monitor, and the Dekati two-stage cascade impactor with cutoff sizes of 10 and 4 m. The study confirmed the applicability of the IOM and Button samplers. The new foam product followed the respirable criteria well. However, the foam sampler was unstable for measuring inhalable dust, probably due to its moisture absorption. In addition, high dust loads should be avoided with the foam sampler due to increase in filtering efficiency. The concentrations of inhalable dust measured with the Button sampler, the Grimm monitor, and the impactor sampler were usually close to those measured with the reference sampler. On the other hand, impactor sampling yielded higher respirable dust concentrations than the reference method in the field, which may have been caused by particle bounce; high dust loads should be avoided while using the impactor. The results also showed that the Grimm monitor enables real-time dust concentration determinations that are accurate enough for routine monitoring of occupational exposure and for testing efficiency of control measures in workplaces.
引用
收藏
页码:28 / 35
页数:8
相关论文
共 50 条
  • [21] Occupational exposure to respirable and inhalable dust and its components in a Nicaraguan sugarcane plantation
    d'Errico, Antonio
    Peraza, Sandra
    Weiss, Ilana
    Martinez, William
    Monge, Esteban Arias
    Wouters, Inge Maria
    Wegman, David H.
    Jakobsson, Kristina
    Kromhout, Hans
    OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2025,
  • [22] Identification of agricultural tasks important to cumulative exposures to inhalable and respirable dust in California
    Wu, JD
    Nieuwenhuijsen, MJ
    Samuels, SJ
    Lee, K
    Schenker, MB
    AIHA JOURNAL, 2003, 64 (06): : 830 - 836
  • [23] LABORATORY CALIBRATION OF A RESPIRABLE DUST SAMPLING - X-RAY DIFFRACTION TECHNIQUE FOR QUARTZ ANALYSIS
    KNIGHT, G
    STEFANIC.W
    IRELAND, G
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1971, 32 (05): : 16 - &
  • [24] Inhalable and Respirable Dust Metal Concentration in Existing and Construction Stage of Airport Infrastructure
    Din, Shamzani Affendy Mohd
    Yahya, Nik Nurul-Hidayah Nik
    Othman, Rashidi
    ADVANCED SCIENCE LETTERS, 2017, 23 (07) : 6123 - 6126
  • [25] Assessment of Inhalable and Respirable Dust for Four Poultry Farms in Dakahlia Governorate, Egypt
    El-Bahnasy, Hanaa T.
    El-Gammal, Maie, I
    Hagrus, Ahmed E.
    CATRINA-THE INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCES, 2021, 23 (01) : 45 - 56
  • [26] Variation in the ratio of respirable particulates over inhalable particulates by type of dust workplace
    Okamoto, S
    Nakagoshi, S
    Ukai, H
    Takada, S
    Inui, S
    Higashikawa, K
    Ikeda, M
    INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1998, 71 (02) : 111 - 116
  • [27] FIELD COMPARISON OF RESPIRABLE DUST SAMPLERS
    VERMA, DK
    SEBESTYEN, A
    JULIAN, JA
    MUIR, DCF
    ANNALS OF OCCUPATIONAL HYGIENE, 1992, 36 (01): : 23 - &
  • [28] A FIELD COMPARISON OF RESPIRABLE DUST SAMPLERS
    GROVES, WA
    HAHNE, RMA
    LEVINE, SP
    SCHORK, MA
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1994, 55 (08): : 748 - 755
  • [29] DESIGN, CONSTRUCTION AND TESTING OF A LABORATORY CHAMBER FOR DUST GENERATION AND SAMPLING
    Krestou, A.
    Triantafyllou, A. G.
    Garas, S.
    Tsekouras, V.
    Diamantopoulos, C.
    PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2013,
  • [30] Optimization of a sampling cyclone to the new international sampling convention for respirable dust
    Liden, G.
    Gudmundsson, A.