Laboratory and field testing of sampling methods for inhalable and respirable dust

被引:19
|
作者
Linnainmaa, Markku [1 ]
Laitinen, Juha [1 ]
Leskinen, Ari [2 ]
Sippula, Olli [3 ]
Kalliokoski, Pentti [3 ]
机构
[1] Finnish Inst Occupat Hlth, FI-70701 Kuopio, Finland
[2] Finnish Meteorol Inst, Kuopio Unit, Kuopio, Finland
[3] Univ Kuopio, FIN-70211 Kuopio, Finland
关键词
aerosol monitoring; cascade impactor; inhalable dust; IOM samplers; particle size-selective sampling; respirable dust;
D O I
10.1080/15459620701763723
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The performance of four sampling devices for inhalable dust and three devices for respirable dust was tested with different kinds of dusts in the laboratory and in the field. The IOM sampler was chosen as the reference method for inhalable dust, and the IOM sampler provided with the porous plastic foam media was used as the reference method for respirable dust. The other tested instruments were the Button sampler, the optical Grimm aerosol monitor, and the Dekati two-stage cascade impactor with cutoff sizes of 10 and 4 m. The study confirmed the applicability of the IOM and Button samplers. The new foam product followed the respirable criteria well. However, the foam sampler was unstable for measuring inhalable dust, probably due to its moisture absorption. In addition, high dust loads should be avoided with the foam sampler due to increase in filtering efficiency. The concentrations of inhalable dust measured with the Button sampler, the Grimm monitor, and the impactor sampler were usually close to those measured with the reference sampler. On the other hand, impactor sampling yielded higher respirable dust concentrations than the reference method in the field, which may have been caused by particle bounce; high dust loads should be avoided while using the impactor. The results also showed that the Grimm monitor enables real-time dust concentration determinations that are accurate enough for routine monitoring of occupational exposure and for testing efficiency of control measures in workplaces.
引用
收藏
页码:28 / 35
页数:8
相关论文
共 50 条
  • [1] INHALABLE, TOTAL AND RESPIRABLE DUST - A FIELD-STUDY
    VERMA, DK
    ANNALS OF OCCUPATIONAL HYGIENE, 1984, 28 (02): : 163 - &
  • [2] Occupational exposure to inhalable and respirable dust fractions
    Arnone, M.
    Gabriel, S.
    Mattenklott, M.
    Koob, M.
    Guldner, K.
    Poppe, M.
    Froehlich, H-P
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2021, 81 (3-4): : 81 - 90
  • [3] Means of converting the concentration of inhalable to respirable dust
    Wippich, C.
    Koppisch, D.
    Breuer, D.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2019, 79 (09): : 303 - 311
  • [4] RESPIRABLE DUST SAMPLING
    LIPPMANN, M
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1970, 31 (02): : 138 - &
  • [5] Estimating Respirable Dust Exposure from Inhalable Dust Exposure
    Wippich, Cornelia
    Rissler, Joerg
    Koppisch, Dorothea
    Breuer, Dietmar
    ANNALS OF WORK EXPOSURES AND HEALTH, 2020, 64 (04) : 430 - 444
  • [6] COMPARISON OF THE CRITERIA FOR SAMPLING INHALABLE AND RESPIRABLE AEROSOLS
    RAABE, OG
    ANNALS OF OCCUPATIONAL HYGIENE, 1982, 26 (1-4): : 33 - 45
  • [7] Estimating nickel exposure in respirable dust from nickel in inhalable dust
    Wippich, Cornelia
    Koppisch, Dorothea
    Pitzke, Katrin
    Breuer, Dietmar
    INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2021, 238
  • [8] Estimating cobalt exposure in respirable dust from cobalt in inhalable dust
    Wippich, Cornelia
    Koppisch, Dorothea
    Pitzke, Katrin
    Breuer, Dietmar
    INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2022, 242
  • [9] SAMPLING FOR RESPIRABLE COTTON DUST
    ROBERT, KQ
    BARIL, A
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1981, 58 (07) : A589 - A589
  • [10] SAMPLING FOR RESPIRABLE COTTON DUST
    ROBERT, KQ
    BARIL, A
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1984, 61 (10) : 1553 - 1558