Operation of fault-tolerant inverters with DC-link midpoint connection for adjustable speed drives

被引:0
|
作者
Gleissner, Michael [1 ]
Bakran, Mark-M. [1 ]
机构
[1] Univ Bayreuth, Ctr Energy Technol, Dept Mechatron, Univ Str 30, Bayreuth, Germany
关键词
Fault handling strategy; Variable speed drive; Fault tolerance; Multilevel converters; Voltage Source Converter (VSC); CONVERTER; TOPOLOGIES; COST;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Some fault-tolerant three-phase inverters are based upon a reconfiguration to an inverter with only two active phases and a DC-link midpoint connection after any semiconductor failure. Thus, the maximum output voltage is halved and the DC-link midpoint capacitor voltage ripple depends on output frequency and output current of the inverter. These limiting effects on the operation range of adjustable speed drives as well as software and hardware based countermeasures are presented in this paper.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Speed sensorless fault-tolerant control of induction motor drives against current sensor fault
    Azizollah Gholipour
    Mahmood Ghanbari
    Esmaeil Alibeiki
    Mohammad Jannati
    Electrical Engineering, 2021, 103 : 1493 - 1513
  • [42] Analysis and Design of Active Inductor as DC-Link Reactor for Lightweight Adjustable Speed Drive Systems
    Rana, Dibyendu
    Hafez, Bahaa
    Garg, Pawan
    Essakiappan, Somasundaram
    Enjeti, Prasad
    2014 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2014, : 3243 - 3250
  • [43] Sliding Mode Based Incipient Sensor Fault-Tolerant Control for DC Servomotor Drives
    Kommuri, Suneel K.
    Rath, Jagat J.
    Shafiq, G.
    Gonuguntla, V.
    Veluvolu, Kalyana C.
    2017 14TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2017, : 733 - 736
  • [44] Easy Hall position sensor fault-tolerant control algorithm for brushless DC drives
    Lv, Degang
    Li, Song
    Du, Zeyuan
    IEICE ELECTRONICS EXPRESS, 2019, 16 (06):
  • [45] Fault-Tolerant Operation of Cascaded H-Bridge Inverters Using One Redundant Cell
    Moamaei, Parvin
    Mahmoudi, Hamid
    Ahmadi, Reza
    2015 IEEE POWER AND ENERGY CONFERENCE AT ILLINOIS (PECI), 2015,
  • [46] Fault-Tolerant Operation of Asymmetrical Six-Phase Motor Drives in EV Applications
    Salem, Ahmed
    Narimani, Mehdi
    2020 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE & EXPO (ITEC), 2020, : 210 - 215
  • [47] Fault-tolerant operation of some reduced-device-count multilevel inverters with improved performance
    Dewangan, Niraj Kumar
    Gupta, Shubhrata
    Gupta, Krishna Kumar
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2019, 29 (02)
  • [48] Fault-tolerant analysis of two boost inverters for open-end winding induction motor drives
    Chunjie Li
    Guifeng Wang
    Hongmei Li
    Fei Li
    Zhenglong Xia
    Zhan Liu
    Journal of Power Electronics, 2021, 21 : 647 - 659
  • [49] Fault-tolerant analysis of two boost inverters for open-end winding induction motor drives
    Li, Chunjie
    Wang, Guifeng
    Li, Hongmei
    Li, Fei
    Xia, Zhenglong
    Liu, Zhan
    JOURNAL OF POWER ELECTRONICS, 2021, 21 (04) : 647 - 659
  • [50] Winding open-circuit fault-tolerant operation of single DC-link dual-inverter fed three-phase open-end induction motor drive
    Chakrabarti, Abanishwar
    Saha, Ardhendu
    Biswas, Sujit K.
    IET POWER ELECTRONICS, 2021, 14 (07) : 1256 - 1270