Operation of fault-tolerant inverters with DC-link midpoint connection for adjustable speed drives

被引:0
|
作者
Gleissner, Michael [1 ]
Bakran, Mark-M. [1 ]
机构
[1] Univ Bayreuth, Ctr Energy Technol, Dept Mechatron, Univ Str 30, Bayreuth, Germany
关键词
Fault handling strategy; Variable speed drive; Fault tolerance; Multilevel converters; Voltage Source Converter (VSC); CONVERTER; TOPOLOGIES; COST;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Some fault-tolerant three-phase inverters are based upon a reconfiguration to an inverter with only two active phases and a DC-link midpoint connection after any semiconductor failure. Thus, the maximum output voltage is halved and the DC-link midpoint capacitor voltage ripple depends on output frequency and output current of the inverter. These limiting effects on the operation range of adjustable speed drives as well as software and hardware based countermeasures are presented in this paper.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Fault Tolerant Control of Adjustable Speed Switched Reluctance Motor Drives
    Wang, Wei
    Fahimi, Babak
    2013 IEEE WORKSHOP ON ELECTRICAL MACHINES DESIGN, CONTROL AND DIAGNOSIS (WEMDCD), 2013,
  • [22] Reducing DC Link Voltage Unbalance in a Fault-Tolerant Inverter
    Boscaino, V.
    Di Tommaso, A. O.
    Genduso, F.
    Miceli, R.
    2014 16TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE AND EXPOSITION (PEMC), 2014, : 1312 - 1317
  • [23] Fault-Tolerant Voltage-Source-Inverters for Switched Reluctance Motor Drives
    Cordeiro, Armando
    Fernao Pires, V.
    Pires, A. J.
    Martins, J. F.
    Chen, Hao
    2019 IEEE 13TH INTERNATIONAL CONFERENCE ON COMPATIBILITY, POWER ELECTRONICS AND POWER ENGINEERING (CPE-POWERENG), 2019,
  • [24] Condition Monitoring of DC Link Electrolytic Capacitors in Adjustable Speed Drives
    Kim, Myungchul
    Lee, Kwangwoon
    Yoon, Jangho
    Lee, Sang Bin
    Yoo, Jiyoon
    CONFERENCE RECORD OF THE 2007 IEEE INDUSTRY APPLICATIONS CONFERENCE FORTY-SECOND IAS ANNUAL MEETING, VOLS. 1-5, 2007, : 237 - 243
  • [25] Multi-phase fault-tolerant brushless DC motor drives
    Gopalarathnam, T
    Toliyat, HA
    Moreira, JC
    IAS 2000 - CONFERENCE RECORD OF THE 2000 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-5, 2000, : 1683 - 1688
  • [26] A FAULT-TOLERANT ASSOCIATIVE MEMORY WITH HIGH-SPEED OPERATION
    BERGH, H
    ENELAND, J
    LUNDSTROM, LE
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1990, 25 (04) : 912 - 919
  • [27] Fault-tolerant operation of induction motor drives with automatic controller reconfiguration
    Raymond B. Sepe
    Chris Morrison
    John M. Miller
    Practical Failure Analysis, 2003, 3 (1) : 64 - 70
  • [28] Modulation strategies for fault-tolerant operation of H-bridge multilevel inverters
    Correa, Pablo
    Pacas, Mario
    Rodriguez, Jose
    2006 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-7, 2006, : 1589 - +
  • [29] DC-Link Sensor Fault Detection and Isolation for Railway Traction Electric Drives
    del Olmo, Jon
    Garramiola, Fernando
    Poza, Javier
    Nieva, Txomin
    Almandoz, Gaizka
    Aldasoro, Leire
    2017 IEEE WORKSHOP ON ELECTRICAL MACHINES DESIGN, CONTROL AND DIAGNOSIS (WEMDCD), 2017,
  • [30] Swinging Bus Operation of Inverters for Fuel Cell Applications With Small DC-Link Capacitance
    Galvez, Juan M.
    Ordonez, Martin
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (02) : 1064 - 1075