Operation of fault-tolerant inverters with DC-link midpoint connection for adjustable speed drives

被引:0
|
作者
Gleissner, Michael [1 ]
Bakran, Mark-M. [1 ]
机构
[1] Univ Bayreuth, Ctr Energy Technol, Dept Mechatron, Univ Str 30, Bayreuth, Germany
关键词
Fault handling strategy; Variable speed drive; Fault tolerance; Multilevel converters; Voltage Source Converter (VSC); CONVERTER; TOPOLOGIES; COST;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Some fault-tolerant three-phase inverters are based upon a reconfiguration to an inverter with only two active phases and a DC-link midpoint connection after any semiconductor failure. Thus, the maximum output voltage is halved and the DC-link midpoint capacitor voltage ripple depends on output frequency and output current of the inverter. These limiting effects on the operation range of adjustable speed drives as well as software and hardware based countermeasures are presented in this paper.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Stability Analysis and Improvement of V/Hz Controlled Adjustable Speed Drives Equipped with Small DC-Link Thin Film Capacitors
    Qian, Zhentian
    Yao, Wenxi
    Lee, Kevin
    THIRTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2018), 2018, : 861 - 866
  • [32] Fault-Tolerant Operation of the DC/DC Modular Multilevel Converter Under Submodule Failure
    Razani, Ramin
    Mohamed, Yasser Abdel-Rady I.
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2021, 9 (05) : 6139 - 6151
  • [33] Fault-Tolerant PMSG Direct-Drive Wind Turbines, using Vector Control Techniques with Reduced DC-Link Ratings
    Jlassi, Imed
    Bento, Fernando
    Marques Cardoso, Antonio J.
    IECON 2018 - 44TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2018, : 1214 - 1219
  • [34] Application of Real-Time Fault-Tolerant Distributed Control in Parallel Operation of Inverters
    Quesada, Jeronimo
    Antonio Sainz, Jose
    Sebastian, Rafael
    Castro, Manuel
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 471 - 476
  • [35] Fault tolerant DC-link single-phase to single-phase converter
    Jacobina, C. B.
    dos Santos, E. C., Jr.
    de Freitas, I. S.
    da Silva, E. R. C.
    Oliveira, T. M.
    Correa, M. B. R.
    2006 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-7, 2006, : 545 - 551
  • [36] DC-Link Voltage and Catenary Current Sensors Fault Reconstruction for Railway Traction Drives
    Garramiola, Fernando
    Poza, Javier
    del Olmo, Jon
    Madina, Patxi
    Almandoz, Gaizka
    SENSORS, 2018, 18 (07)
  • [37] Sensorless Speed Control of a Fault-Tolerant Five-Phase PMSM Drives
    Saleh, Kamel
    Sumner, Mark
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2020, 48 (9-10) : 919 - 932
  • [38] Speed sensorless fault-tolerant control of induction motor drives against current sensor fault
    Gholipour, Azizollah
    Ghanbari, Mahmood
    Alibeiki, Esmaeil
    Jannati, Mohammad
    ELECTRICAL ENGINEERING, 2021, 103 (03) : 1493 - 1513
  • [39] A Robust Voltage, Speed and Current Sensors Fault-Tolerant Control in PMSM Drives
    Kommuri, Suneel Kumar
    Lee, Sang Bin
    Park, Yonghyun
    Veluvolu, Kalyana C.
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 2937 - 2942
  • [40] Fault tolerant operations in adjustable-speed drives and soft starters for induction motors
    Yeh, Chia-Chou
    Demerdash, Nabeel A. O.
    2007 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, 2007, : 1942 - 1949