Impact of Axial Compression for the mMR Simultaneous PET-MR Scanner

被引:0
|
作者
Belzunce, Martin A. [1 ]
O'Doherty, Jim [1 ]
Reader, Andrew J. [1 ]
机构
[1] Kings Coll London, St Thomas Hosp, Div Imaging Sci & Biomed Engn, London, England
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In 3D PET an axial compression is often applied to reduce the data size and the computation times during image reconstruction. This compression scheme can achieve good results in the centre of the FOV. However, there is a loss in the spatial resolution at off-centre positions and this effect is increased in scanners with a larger FOV. This is the case for the Siemens Biograph mMR, which by default uses an axial compression of span 11. An assessment of the improvement in the spatial resolution that would be achieved in a reconstruction without axial compression, is necessary to evaluate if the additional computational burden is justified for routine image reconstruction. In this work, we present an implementation of the ordinary Poisson ordered subsets expectation maximization (OP-OSEM) algorithm without axial compression for the mMR, and evaluate its performance for span 1 and span 11. We show that an improvement of 3 mm FWHM (i.e. an improvement of 40%) can be achieved when span 11 compression is avoided and the source is at a distance greater than 100 mm from the centre of the FOV. In addition, the general image quality properties of the algorithm were evaluated with a NEMA image quality phantom acquisition and contrasted with its reconstruction via the STIR open source reconstruction software.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] Simultaneous acquisition of multislice PET and MR images: Initial results with a MR-compatible PET scanner
    Catana, Ciprian
    Wu, Yibao
    Judenhofer, Martin S.
    Qi, Jinyi
    Pichler, Berrid J.
    Cherry, Simon R.
    JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (12) : 1968 - 1976
  • [42] MR-Based Motion Correction in Coronary 18F-Fluoride PET Imaging Using Simultaneous PET-MR
    Petibon, Y.
    Wilks, M. Q.
    Ma, C.
    Huang, C.
    Lu, M. T.
    Zanni, M. K.
    Grinspoon, S. K.
    Ouyang, J.
    El Fakhri, G.
    MEDICAL PHYSICS, 2017, 44 (06) : 3139 - 3139
  • [43] Clinical applications of hybrid PET-MR
    Ratib, O.
    Lord, M.
    Becker, M.
    Viallon, M.
    Vallee, J. -P.
    Loubeyre, P.
    Willi, J. -P.
    Rager, O.
    Garibotto, V.
    Zaidi, H.
    Fleury, E.
    Figueiral, A.
    Becker, C.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2012, 36 (10): : 605 - 614
  • [44] PET-MR - A Solution looking for a Problem?
    Mayerhoefer, M. E.
    Herold, C. J.
    RADIOLOGE, 2013, 53 (08): : 667 - 668
  • [45] PET-MR in patients with glioblastoma multiforme
    Ertl-Wagner, B.
    Ingrisch, M.
    Niyazi, M.
    Schnell, O.
    Jansen, N.
    Forster, S.
    la Fougere, C.
    RADIOLOGE, 2013, 53 (08): : 682 - 690
  • [46] A review of PET attenuation correction methods for PET-MR
    Georgios Krokos
    Jane MacKewn
    Joel Dunn
    Paul Marsden
    EJNMMI Physics, 10
  • [47] PET-MR Imaging in Head and Neck
    Lee, Yueh Z.
    Ramaiho, Joana
    Kessler, Brice
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2017, 25 (02) : 315 - +
  • [48] MOLECULAR IMAGING WITH PET-CT AND PET-MR
    Beuthien-Baumann, B.
    RADIOTHERAPY AND ONCOLOGY, 2012, 104 : 27 - 27
  • [49] A review of PET attenuation correction methods for PET-MR
    Krokos, Georgios
    Mackewn, Jane
    Dunn, Joel
    Marsden, Paul
    EJNMMI PHYSICS, 2023, 10 (01)
  • [50] Addressing PET Attenuation Correction Challenges for the ACR Accreditation of a Simultaneous PET/MR Scanner
    Kulkarni, H.
    Samuels, A.
    Faasse, T.
    Sridhar, V.
    Hu, L.
    Botti, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S693 - S693