Impact of Axial Compression for the mMR Simultaneous PET-MR Scanner

被引:0
|
作者
Belzunce, Martin A. [1 ]
O'Doherty, Jim [1 ]
Reader, Andrew J. [1 ]
机构
[1] Kings Coll London, St Thomas Hosp, Div Imaging Sci & Biomed Engn, London, England
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In 3D PET an axial compression is often applied to reduce the data size and the computation times during image reconstruction. This compression scheme can achieve good results in the centre of the FOV. However, there is a loss in the spatial resolution at off-centre positions and this effect is increased in scanners with a larger FOV. This is the case for the Siemens Biograph mMR, which by default uses an axial compression of span 11. An assessment of the improvement in the spatial resolution that would be achieved in a reconstruction without axial compression, is necessary to evaluate if the additional computational burden is justified for routine image reconstruction. In this work, we present an implementation of the ordinary Poisson ordered subsets expectation maximization (OP-OSEM) algorithm without axial compression for the mMR, and evaluate its performance for span 1 and span 11. We show that an improvement of 3 mm FWHM (i.e. an improvement of 40%) can be achieved when span 11 compression is avoided and the source is at a distance greater than 100 mm from the centre of the FOV. In addition, the general image quality properties of the algorithm were evaluated with a NEMA image quality phantom acquisition and contrasted with its reconstruction via the STIR open source reconstruction software.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] Simultaneous PET-MR acquisition and MR-derived motion fields for correction of non-rigid motion in PET
    Tsoumpas, Charalampos
    Mackewn, Jane E.
    Halsted, Philip
    King, Andrew P.
    Buerger, Christian
    Totman, John J.
    Schaeffter, Tobias
    Marsden, Paul K.
    ANNALS OF NUCLEAR MEDICINE, 2010, 24 (10) : 745 - 750
  • [32] Verification of the MR components attenuation maps for an MR/PET scanner with simultaneous acquisition
    Eldib, Mootaz
    Faul, David
    Pawlak, John
    Doshi, Niraj
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [33] Assessment of PET & ASL metabolism in the hippocampal subfields of MCI and AD using simultaneous PET-MR
    Maged Goubran
    David Douglas
    Steven Chao
    Andrew Quon
    Pragya Tripathi
    Dawn Holley
    Minal Vasanawala
    Greg Zaharchuk
    Michael Zeineh
    EJNMMI Physics, 2 (Suppl 1)
  • [34] CONTINUOUS SCINTILLATOR DETECTOR BLOCKS FOR SIMULTANEOUS PET-MR IMAGING OF THE HUMAN BRAIN
    Rato Mendes, Pedro
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2010, 5 : 121 - 127
  • [35] Towards coronary plaque imaging using simultaneous PET-MR: a simulation study
    Petibon, Y.
    El Fakhri, G.
    Nezafat, R.
    Johnson, N.
    Brady, T.
    Ouyang, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (05): : 1203 - 1222
  • [36] Highly Efficient Motion-Corrected Simultaneous Cardiac PET-MR Imaging
    Munoz, Camila
    Neji, Radhouene
    Marsden, Paul
    Reader, Andrew J.
    Botnar, Rene M.
    Prieto, Claudia
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [37] MR-based motion correction for PET imaging using wired active MR microcoils in simultaneous PET-MR: Phantom studya)
    Huang, Chuan
    Ackerman, Jerome L.
    Petibon, Yoann
    Brady, Thomas J.
    El Fakhri, Georges
    Ouyang, Jinsong
    MEDICAL PHYSICS, 2014, 41 (04)
  • [38] Developing quality assurance tests for simultaneous PET-MR imaging for radiotherapy planning
    Wyatt, J.
    Howell, E.
    McCallum, H.
    Maxwell, R.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S321 - S323
  • [39] Scatter Effects of MR Components in PET-MR Inserts
    Keereman, Vincent
    Vandenberghe, Stefaan
    De Beenhouwer, Jan
    Van Holen, Roe
    Staelens, Steven
    Schulz, Volkmar
    Solf, Torsten
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3804 - +
  • [40] Comparative Evaluation of Image Reconstruction Methods for the Siemens PET-MR Scanner Using the STIR Library
    Deidda, Daniel
    Efthimiou, Nikos
    Manber, Richard
    Thielemans, Kris
    Markiewicz, Pawel
    Aykroyd, Robert G.
    Tsoumpas, Charalampos
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,