An in vitro model for fluid pressurization of screw holes in metal-backed total joint components

被引:7
|
作者
Kurtz, SM
Harrigan, TP
Herr, M
Manley, MT
机构
[1] Exponent Inc, Philadelphia, PA 19104 USA
[2] Drexel Univ, Philadelphia, PA 19104 USA
来源
JOURNAL OF ARTHROPLASTY | 2005年 / 20卷 / 07期
关键词
osteolysis; fluid pressure; implant design; conformity; thickness; surface finish;
D O I
10.1016/j.arth.2004.11.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Fluid pressure may stimulate osteolysis near screw holes in joint arthroplasty components. We developed a generalized in vitro model of a polyethylene liner and metal backing with a screw hole to investigate whether implant design factors influence local fluid pressure. We observed an order of magnitude of variation in the peak screw hole pressure (from 16.0 and 163 kPa) under clinically relevant loading conditions. Of the implant factors investigated, the surface finish of the metallic base plate had the greatest effect on peak screw hole fluid pressures; the thickness of the polyethylene liner, as well as the gap between the liner and the base plate, were also significant design variables. Our data suggest that unpolished metal base plates, thick polyethylene liners, and tight conformity between the liner and the metal base plate will all contribute to significantly reduced peak screw hole fluid pressures in joint arthroplasty.
引用
收藏
页码:932 / 938
页数:7
相关论文
共 50 条
  • [21] Porous-coated metal-backed patellar components in total knee replacement - A postmortem retrieval analysis
    Bloebaum, RD
    Bachus, KN
    Jensen, JW
    Scott, DF
    Hofmann, AA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (04): : 518 - 528
  • [22] Migration of all-polyethylene compared with metal-backed tibial components in cemented total knee arthroplasty
    van Hamersveld, Koen T.
    Marang-Van de Mheen, Perla J.
    Nelissen, Rob G. H. H.
    Toksvig-Larsen, Soren
    ACTA ORTHOPAEDICA, 2018, 89 (04) : 412 - 417
  • [23] Modern trabecular metal-backed glenoid components in total shoulder arthroplasty: What is the evidence? A systematic review
    Malahias, Michael-Alexander
    Chytas, Dimitrios
    Kostretzis, Lazaros
    Trellopoulos, Angelos
    Brilakis, Emmanouil
    Antonogiannakis, Emmanouil
    SHOULDER & ELBOW, 2021, 13 (01) : 29 - 37
  • [24] A randomized comparison of all-polyethylene and metal-backed tibial components
    Gioe, TJ
    Bowman, KR
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (380) : 108 - 115
  • [25] Outcome of metal-backed cementless patellar components - The effect of implant design
    Kraay, MJ
    Darr, OJ
    Salata, MJ
    Goldberg, VM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (392) : 239 - 244
  • [26] Polyethylene wear in metal-backed tibial components in unicompartmental knee prostheses
    Makaram, Navnit S.
    Yapp, Liam Z.
    Bowley, Abigail L. W.
    Garner, Amy
    Scott, Chloe E. H.
    JOURNAL OF ISAKOS JOINT DISORDERS & ORTHOPAEDIC SPORTS MEDICINE, 2024, 9 (06)
  • [27] FAILURE OF METAL-BACKED UNCEMENTED PATELLAR COMPONENTS - REPORT ON 3 CASES
    FELMET, G
    DENICOLA, U
    SPRINGORUM, HW
    ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (06): : 715 - 717
  • [28] The case for the metal-backed glenoid design in total anatomical shoulder arthroplasty
    Denis C. Katz
    P. Sauzières
    P. Valenti
    J. Kany
    European Journal of Orthopaedic Surgery & Traumatology, 2012, 22 : 9 - 16
  • [29] The case for the metal-backed glenoid design in total anatomical shoulder arthroplasty
    Katz, Denis C.
    Sauzieres, P.
    Valenti, P.
    Kany, J.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2012, 22 (01): : 9 - 16
  • [30] FAILURE OF THE METAL-BACKED PATELLAR COMPONENT AFTER TOTAL KNEE REPLACEMENT
    BAYLEY, JC
    SCOTT, RD
    EWALD, FC
    HOLMES, GB
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (05): : 668 - 674