An in vitro model for fluid pressurization of screw holes in metal-backed total joint components

被引:7
|
作者
Kurtz, SM
Harrigan, TP
Herr, M
Manley, MT
机构
[1] Exponent Inc, Philadelphia, PA 19104 USA
[2] Drexel Univ, Philadelphia, PA 19104 USA
来源
JOURNAL OF ARTHROPLASTY | 2005年 / 20卷 / 07期
关键词
osteolysis; fluid pressure; implant design; conformity; thickness; surface finish;
D O I
10.1016/j.arth.2004.11.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Fluid pressure may stimulate osteolysis near screw holes in joint arthroplasty components. We developed a generalized in vitro model of a polyethylene liner and metal backing with a screw hole to investigate whether implant design factors influence local fluid pressure. We observed an order of magnitude of variation in the peak screw hole pressure (from 16.0 and 163 kPa) under clinically relevant loading conditions. Of the implant factors investigated, the surface finish of the metallic base plate had the greatest effect on peak screw hole fluid pressures; the thickness of the polyethylene liner, as well as the gap between the liner and the base plate, were also significant design variables. Our data suggest that unpolished metal base plates, thick polyethylene liners, and tight conformity between the liner and the metal base plate will all contribute to significantly reduced peak screw hole fluid pressures in joint arthroplasty.
引用
收藏
页码:932 / 938
页数:7
相关论文
共 50 条
  • [41] Iatrogenic induced metallosis of the knee joint resulting from failure of a metal-backed patella [Iatrogenes "metallom" (Titanom) durch implantatversagen bei "metal-backed" patellagelenkflächenersatz]
    Büttner-Janz K.
    Müller M.
    Müller K.-M.
    Friemann J.
    Der Unfallchirurg, 2002, 105 (3): : 278 - 282
  • [42] All-polyethylene versus metal-backed and stemmed tibial components in cemented total hip arthroplasty -: Authors' reply
    Nilsson, KG
    Adalberth, G
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (04): : 619 - 619
  • [43] Wear-through of metal-backed acetabular shell in total hip arthroplasty
    Huang, KY
    Liu, HC
    Hou, SM
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2003, 102 (05) : 334 - 337
  • [44] Long-Term Results of Cemented Metal-Backed Glenoid Components for Osteoarthritis of the Shoulder
    Tammachote, Nattapol
    Sperling, John W.
    Vathana, Torpon
    Cofield, Robert H.
    Harmsen, W. Scott
    Schleck, Cathy D.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (01): : 160 - 166
  • [45] Retention of superficially damaged femoral components after metal-backed patella component failure
    Garcia, Ryan M.
    Kraay, Matthew J.
    Goldberg, Victor M.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (06): : 850 - 858
  • [46] Iatrogenic induced metallosis of the knee joint resulting from failure of a metal-backed patella
    Büttner-Janz, K
    Müller, M
    Müller, KM
    Friemann, J
    UNFALLCHIRURG, 2002, 105 (03): : 278 - 282
  • [47] Cementing acetabular sockets into metal-backed acetabular components and antiprotrusio cages: A technical tip
    Ezzet, Kace A.
    JOURNAL OF ARTHROPLASTY, 2007, 22 (04): : 609 - 611
  • [48] Fracture of a Metal-Backed Ceramic Liner After Total Hip Arthroplasty: A Case Report
    Diciurcio, William
    Lutz, Rex W.
    Smith, Eric B.
    Deirmengian, Gregory K.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (07)
  • [49] Mid-term results of a metal-backed glenoid component in total shoulder replacement
    Castagna, A.
    Randelli, M.
    Garofalo, R.
    Maradei, L.
    Giardella, A.
    Borroni, M.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (10): : 1410 - 1415
  • [50] Management of failed metal-backed glenoid component in patients with bilateral total shoulder arthroplasty
    Li, Xinning
    Eichinger, Josef K.
    Higgins, Laurence D.
    INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2013, 7 (04): : 143 - 148