Porous-coated metal-backed patellar components in total knee replacement - A postmortem retrieval analysis

被引:28
|
作者
Bloebaum, RD
Bachus, KN
Jensen, JW
Scott, DF
Hofmann, AA
机构
[1] Vet Affairs Med Ctr, Bone & Joint Res Lab 151F, Salt Lake City, UT 84148 USA
[2] Vet Affairs Med Ctr, Sect Orthopaed, Salt Lake City, UT 84148 USA
[3] Univ Utah, Dept Orthopaed, Orthopaed Bioengn Res Lab, Salt Lake City, UT 84112 USA
来源
关键词
D O I
10.2106/00004623-199804000-00008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The use of porous-coated metal-backed patellar components to achieve consistent fixation by bone ingrowth and to provide relief of pain warrants serious scrutiny. We conducted a quantitative postmortem investigation of eleven consecutively retrieved components with use of high-resolution contact radiographs, electron microscopy, and histological analysis, The implants had been in situ for a mean (and standard deviation) of 45 +/- 36 months (range, one to eighty-four months). Analysis of the high-resolution contact radiographs revealed that a mean of 86 +/- 12 per cent (range, 61 to 100 per cent) of the porous coating was in contact with the host bone. Backscattered electron imaging showed that the mean volume fraction of bone ingrowth was 13 +/- 9 per cent (range, 0 to 30 per cent), No significant difference was detected, with the numbers available, between the volume fraction of the bone ingrowth measured in the porous coating and that of the host cancellous bone in the patellae, CLINICAL RELEVANCE: Our data support the hypothesis that the amount of host bone determines the amount of bone that can grow into the porous coating, These results differ from those of previous studies of metal-backed patellar components, in which clinical complications attributed to the absence of bone ingrowth were noted within the first thirty-five months after implantation, The current study is the first of which we are aware to demonstrate that it is possible to achieve consistent bone growth into porous-coated metal-backed patellar components.
引用
收藏
页码:518 / 528
页数:11
相关论文
共 50 条
  • [1] TOTAL KNEE REPLACEMENT - RADIOLOGIC FINDINGS IN FAILURE OF POROUS-COATED METAL-BACKED PATELLAR COMPONENT
    PIRAINO, D
    RICHMOND, B
    FREED, H
    BELHOBEK, G
    SCHILS, J
    STULBERG, B
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (03) : 555 - 558
  • [2] FAILURE OF THE METAL-BACKED PATELLAR COMPONENT AFTER TOTAL KNEE REPLACEMENT
    BAYLEY, JC
    SCOTT, RD
    EWALD, FC
    HOLMES, GB
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (05): : 668 - 674
  • [3] EXAMINATION OF POROUS-COATED PATELLAR COMPONENTS AND ANALYSIS OF THE REASONS FOR THEIR RETRIEVAL
    COLLIER, JP
    MAYOR, MB
    SURPRENANT, VA
    SURPRENANT, HP
    JENSEN, RE
    JOURNAL OF APPLIED BIOMATERIALS, 1991, 2 (02) : 95 - 99
  • [4] FRACTURE DISSOCIATION OF THE POLYETHYLENE IN METAL-BACKED PATELLAR COMPONENTS IN TOTAL KNEE ARTHROPLASTY
    LOMBARDI, AV
    ENGH, GA
    VOLZ, RG
    ALBRIGO, JL
    BRAINARD, BJ
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (05): : 675 - 679
  • [5] The porous-coated anatomic total hip prosthesis: Failure of the metal-backed acetabular component
    Astion, DJ
    Saluan, P
    Stulberg, BN
    Rimnac, CM
    Li, S
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (05): : 755 - 766
  • [6] THE USE OF METAL-BACKED PATELLAR PROSTHESES IN TOTAL KNEE ARTHROPLASTY
    LASKIN, RS
    BUCKNELL, A
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (260) : 52 - 55
  • [7] RETRIEVAL ANALYSIS OF POROUS-COATED COMPONENTS FOR TOTAL KNEE ARTHROPLASTY - A REPORT OF 2 CASES
    RANAWAT, CS
    JOHANSON, NA
    RIMNAC, CM
    WRIGHT, TM
    SCHWARTZ, RE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1986, (209) : 244 - 248
  • [8] Metal-backed and all-polyethylene tibial components in total knee replacement
    Rodriguez, JA
    Baez, N
    Rasquinha, V
    Ranawat, CS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (392) : 174 - 183
  • [9] FAILURE MECHANISMS OF METAL-BACKED PATELLAR COMPONENTS
    STULBERG, SD
    STULBERG, BN
    HAMATI, Y
    TSAO, A
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (236) : 88 - 105
  • [10] CONSEQUENCES OF AN INTERFERENCE FIT ON THE FIXATION OF POROUS-COATED TIBIAL COMPONENTS IN TOTAL KNEE REPLACEMENT
    DAWSON, JM
    BARTEL, DL
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (02): : 233 - 238