Porous-coated metal-backed patellar components in total knee replacement - A postmortem retrieval analysis

被引:28
|
作者
Bloebaum, RD
Bachus, KN
Jensen, JW
Scott, DF
Hofmann, AA
机构
[1] Vet Affairs Med Ctr, Bone & Joint Res Lab 151F, Salt Lake City, UT 84148 USA
[2] Vet Affairs Med Ctr, Sect Orthopaed, Salt Lake City, UT 84148 USA
[3] Univ Utah, Dept Orthopaed, Orthopaed Bioengn Res Lab, Salt Lake City, UT 84112 USA
来源
关键词
D O I
10.2106/00004623-199804000-00008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The use of porous-coated metal-backed patellar components to achieve consistent fixation by bone ingrowth and to provide relief of pain warrants serious scrutiny. We conducted a quantitative postmortem investigation of eleven consecutively retrieved components with use of high-resolution contact radiographs, electron microscopy, and histological analysis, The implants had been in situ for a mean (and standard deviation) of 45 +/- 36 months (range, one to eighty-four months). Analysis of the high-resolution contact radiographs revealed that a mean of 86 +/- 12 per cent (range, 61 to 100 per cent) of the porous coating was in contact with the host bone. Backscattered electron imaging showed that the mean volume fraction of bone ingrowth was 13 +/- 9 per cent (range, 0 to 30 per cent), No significant difference was detected, with the numbers available, between the volume fraction of the bone ingrowth measured in the porous coating and that of the host cancellous bone in the patellae, CLINICAL RELEVANCE: Our data support the hypothesis that the amount of host bone determines the amount of bone that can grow into the porous coating, These results differ from those of previous studies of metal-backed patellar components, in which clinical complications attributed to the absence of bone ingrowth were noted within the first thirty-five months after implantation, The current study is the first of which we are aware to demonstrate that it is possible to achieve consistent bone growth into porous-coated metal-backed patellar components.
引用
收藏
页码:518 / 528
页数:11
相关论文
共 50 条
  • [21] Outcome of metal-backed cementless patellar components - The effect of implant design
    Kraay, MJ
    Darr, OJ
    Salata, MJ
    Goldberg, VM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (392) : 239 - 244
  • [22] Cementless porous-coated total knee arthroplasty
    Schroder, HM
    Berthelsen, A
    Hassani, G
    Hansen, EB
    Solgaard, S
    JOURNAL OF ARTHROPLASTY, 2001, 16 (05): : 559 - 567
  • [23] POROUS-COATED TOTAL HIP-REPLACEMENT
    ENGH, CA
    HOOTEN, JP
    ZETTLSCHAFFER, KF
    GHAFFARPOUR, M
    MCGOVERN, TF
    MACALINO, GE
    ZICAT, BA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1994, (298) : 89 - 96
  • [24] FAILURE OF METAL-BACKED UNCEMENTED PATELLAR COMPONENTS - REPORT ON 3 CASES
    FELMET, G
    DENICOLA, U
    SPRINGORUM, HW
    ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (06): : 715 - 717
  • [25] All-polyethylene compared with metal-backed tibial components in total knee arthroplasty
    Hart, WJ
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (08): : 1615 - 1615
  • [26] Uncemented Metal-Backed Tantalum Patellar Components in Total Knee Arthroplasty Have a High Fracture Rate at Midterm Follow-Up
    Chan, Jeremy Y.
    Giori, Nicholas J.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (08): : 2427 - 2430
  • [27] METAL-BACKED PATELLAR COMPONENT FAILURE AND METALLIC SYNOVITIS IN TOTAL KNEE ARTHROPLASTY - A CASE-REPORT
    HALBRECHT, J
    GIORDANO, CP
    JAFFE, WL
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES ORTHOPAEDIC INSTITUTE, 1989, 49 (01): : 48 - 54
  • [28] Postmortem retrieval of total joint replacement components
    Jacobs, JJ
    Patterson, LM
    Skipor, AK
    Hall, DJ
    Urban, RM
    Black, J
    Galante, JO
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1999, 48 (03): : 385 - 391
  • [29] Metal-backed patellar components -: A brief report on 10-year survival
    Crites, BM
    Berend, ME
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (388) : 103 - 104
  • [30] ARTICULAR SURFACE MATERIAL EFFECT ON METAL-BACKED PATELLAR COMPONENTS - A MICROSCOPIC EVALUATION
    MILLIANO, MT
    WHITESIDE, LA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1991, (273) : 204 - 214