Fast MR thermometry using an echo-shifted sequence with simultaneous multi-slice imaging

被引:8
|
作者
Peng, Yuhong [1 ,2 ,3 ]
Zou, Chao [2 ]
Qiao, Yangzi [2 ]
Tie, Changjun [2 ]
Wan, Qian [2 ]
Jiang, Rui [2 ,4 ]
Cheng, Chuanli [2 ,4 ]
Liang, Dong [2 ]
Zheng, Hairong [2 ]
Li, Faqi [1 ,3 ]
Liu, Xin [2 ]
机构
[1] Chongqing Med Univ, Chongqing & Minist Sci & Technol, State Key Lab Ultrasound Engn Med, Chongqing Key Lab Biomed Engn,Coll Biomed Engn, 153 Box,1 Yixueyuan Rd, Chongqing 400016, Peoples R China
[2] Chinese Acad Sci, Shenzhen Inst Adv Technol, Paul C Lauterbur Res Ctr Biomed Imaging, 1068 Xueyuan Blvd, Shenzhen 518055, Guangdong, Peoples R China
[3] Chongqing Collaborat Innovat Ctr Minimally Invas, Chongqing 400016, Peoples R China
[4] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen 518055, Guangdong, Peoples R China
关键词
Magnetic resonance imaging; Thermometry; Simultaneous multi-slice imaging; Echo-shifted sequence; SIGNAL-TO-NOISE; ABDOMINAL ORGANS; HUMAN BRAIN; IN-VIVO; RECONSTRUCTION; PHASE; HIFU; ABLATION; CANCER; SENSITIVITY;
D O I
10.1007/s10334-018-0692-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeReal-time monitoring is important for the safety and effectiveness of high-intensity focused ultrasound (HIFU) therapy. Magnetic resonance imaging is the preferred imaging modality for HIFU monitoring, with its unique capability of temperature imaging. For real-time temperature imaging, higher temporal resolution and larger spatial coverage are needed. In this study, a sequence based on the echo-shifted RF-spoiled gradient echo (GRE) with simultaneous multi-slice (SMS) imaging was designed for fast temperature imaging.MethodsA phantom experiment was conducted to evaluate the accuracy of the echo-shifted sequence using a fluorescent fiber thermometer as reference. The temperature uncertainty of the echo-shifted sequence was compared with the traditional GRE sequence at room temperature through the ex vivo porcine muscle. Finally, the ex vivo porcine liver tissue experiment using HIFU heating was performed to demonstrate that the spatial coverage was increased without decreasing temporal resolution.ResultsThe echo-shifted sequence had a better temperature uncertainty performance compared with the traditional GRE sequence with the same temporal resolution. The ex vivo heating experiment confirmed that by combining the SMS technique and echo-shifted sequence, the spatial coverage was increased without decreasing the temporal resolution while maintaining high temperature measurement precision.ConclusionThe proposed technique was validated as an effective real-time method for monitoring HIFU therapy.
引用
收藏
页码:771 / 779
页数:9
相关论文
共 50 条
  • [1] Fast MR thermometry using an echo-shifted sequence with simultaneous multi-slice imaging
    Yuhong Peng
    Chao Zou
    Yangzi Qiao
    Changjun Tie
    Qian Wan
    Rui Jiang
    Chuanli Cheng
    Dong Liang
    Hairong Zheng
    Faqi Li
    Xin Liu
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2018, 31 : 771 - 779
  • [2] Simultaneous acoustic radiation force imaging and MR thermometry based on a coherent echo-shifted sequence
    Qiao, Yangzi
    Zou, Chao
    Cheng, Chuanli
    Tie, Changjun
    Wan, Qian
    Peng, Hao
    Liang, Dong
    Liu, Xin
    Zheng, Hairong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (09) : 1823 - 1836
  • [3] Simultaneous multi-slice acquisition using a parallel MR Imaging system
    Tai, Hish-Kuo
    Kuo, Li-Wei
    Lin, Yuan-Pin
    Yao, Ching
    Chen, Jyh-Horng
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1652 - 1655
  • [4] Improving diffusion MRI using simultaneous multi-slice echo planar imaging
    Setsompop, K.
    Cohen-Adad, J.
    Gagoski, B. A.
    Raij, T.
    Yendiki, A.
    Keil, B.
    Wedeen, V. J.
    Wald, L. L.
    NEUROIMAGE, 2012, 63 (01) : 569 - 580
  • [5] Ultra-fast brain MR imaging using simultaneous multi-slice acquisition (SMA) technique
    Wu, Edzer L.
    Kuo, Li-Wei
    Wu, Fu-Hsing
    Hsu, Chien-Fang
    Hsieh, Chang-Wei
    Chen, Jyh-Horng
    Chiueh, Tzi-Dar
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 2618 - 2621
  • [6] MR susceptibility contrast imaging using a 2D simultaneous multi-slice gradient-echo sequence at 7T
    Bian, Wei
    Kerr, Adam B.
    Tranvinh, Eric
    Parivash, Sherveen
    Zahneisen, Benjamin
    Han, May H.
    Lock, Christopher B.
    Goubran, Maged
    Zhu, Kongrong
    Rutt, Brian K.
    Zeineh, Michael M.
    PLOS ONE, 2019, 14 (07):
  • [7] In Vivo MR Elastography of Aortic Stiffness Using Multi-Slice Spin-Echo Echo Planar Imaging Sequence: A Comparison to Gradient Recalled Echo Sequence
    Dong, H.
    Jin, N.
    White, R.
    Kolipaka, A.
    MEDICAL PHYSICS, 2022, 49 (06) : E476 - E476
  • [8] Arterial Spin Labeling with Simultaneous Multi-Slice Echo Planar Imaging
    Feinberg, David A.
    Beckett, Alexander
    Chen, Liyong
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (06) : 1500 - 1506
  • [9] Real-time volumetric MR thermometry using 3D echo-shifted sequence under an open source reconstruction platform
    Jiang, Rui
    Jia, Sen
    Qiao, Yangzi
    Chen, Qiaoyan
    Wen, Jianhong
    Liang, Dong
    Liu, Xin
    Zheng, Hairong
    Zou, Chao
    MAGNETIC RESONANCE IMAGING, 2020, 70 : 22 - 28
  • [10] Diffusion-weighted imaging of the kidney: comparison between simultaneous multi-slice and integrated slice-by-slice shimming echo planar sequence
    Zhang, G.
    Sun, H.
    Qian, T.
    An, J.
    Shi, B.
    Zhou, H.
    Liu, Y.
    Peng, X.
    Chen, L.
    Jin, Z.
    CLINICAL RADIOLOGY, 2019, 74 (04) : 325.e1 - 325.e8