Improving diffusion MRI using simultaneous multi-slice echo planar imaging

被引:274
|
作者
Setsompop, K. [1 ,2 ]
Cohen-Adad, J. [1 ,2 ]
Gagoski, B. A. [3 ]
Raij, T. [1 ,2 ]
Yendiki, A. [1 ,2 ]
Keil, B. [1 ,2 ]
Wedeen, V. J. [1 ,2 ]
Wald, L. L. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Dept Radiol, Charlestown, MA 02129 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
关键词
Diffusion MRI; Simultaneous multi-slice; CAIPIRINHA; Parallel imaging; SPIN-ECHO; SELECTIVE EXCITATION; FIBER ORIENTATION; TENSOR MRI; IMAGES; GRADIENT; EPI; RECONSTRUCTIONS; ARRAYS; SIGNAL;
D O I
10.1016/j.neuroimage.2012.06.033
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In diffusion MRI, simultaneous multi-slice single-shot EPI acquisitions have the potential to increase the number of diffusion directions obtained per unit time, allowing more diffusion encoding in high angular resolution diffusion imaging (HARDI) acquisitions. Nonetheless, unaliasing simultaneously acquired, closely spaced slices with parallel imaging methods can be difficult, leading to high g-factor penalties (i.e., lower SNR). The CAIPIRINHA technique was developed to reduce the g-factor in simultaneous multi-slice acquisitions by introducing interslice image shifts and thus increase the distance between aliased voxels. Because the CAIPIRINHA technique achieved this by controlling the phase of the RF excitations for each line of k-space, it is not directly applicable to single-shot EPI employed in conventional diffusion imaging. We adopt a recent gradient encoding method, which we termed "blipped-CAIPI", to create the image shifts needed to apply CAIPIRINHA to EPI. Here, we use pseudo-multiple replica SNR and bootstrapping metrics to assess the performance of the blipped-CAIPI method in 3 x simultaneous multi-slice diffusion studies. Further, we introduce a novel image reconstruction method to reduce detrimental ghosting artifacts in these acquisitions. We show that data acquisition times for Q-ball and diffusion spectrum imaging (DSI) can be reduced 3-fold with a minor loss in SNR and with similar diffusion results compared to conventional acquisitions. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:569 / 580
页数:12
相关论文
共 50 条
  • [1] Arterial Spin Labeling with Simultaneous Multi-Slice Echo Planar Imaging
    Feinberg, David A.
    Beckett, Alexander
    Chen, Liyong
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (06) : 1500 - 1506
  • [2] Accelerated magnetic resonance diffusion tensor imaging of the median nerve using simultaneous multi-slice echo planar imaging with blipped CAIPIRINHA
    Filli, Lukas
    Piccirelli, Marco
    Kenkel, David
    Boss, Andreas
    Manoliu, Andrei
    Andreisek, Gustav
    Bhat, Himanshu
    Runge, Val M.
    Guggenberger, Roman
    EUROPEAN RADIOLOGY, 2016, 26 (06) : 1921 - 1928
  • [3] Accelerated magnetic resonance diffusion tensor imaging of the median nerve using simultaneous multi-slice echo planar imaging with blipped CAIPIRINHA
    Lukas Filli
    Marco Piccirelli
    David Kenkel
    Andreas Boss
    Andrei Manoliu
    Gustav Andreisek
    Himanshu Bhat
    Val M. Runge
    Roman Guggenberger
    European Radiology, 2016, 26 : 1921 - 1928
  • [4] Simultaneous multi-slice readout-segmented echo planar imaging for accelerated diffusion-weighted imaging of the breast
    Filli, Lukas
    Ghafoor, Soleen
    Kenkel, David
    Liu, Wei
    Weiland, Elisabeth
    Andreisek, Gustav
    Frauenfelder, Thomas
    Runge, Val M.
    Boss, Andreas
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (01) : 274 - 278
  • [5] Short-scan-time multi-slice diffusion MRI of the mouse cervical spinal cord using echo planar imaging
    Callot, Virginie
    Duhamel, Guillaume
    Cozzone, Patrick J.
    Kober, Frank
    NMR IN BIOMEDICINE, 2008, 21 (08) : 868 - 877
  • [6] Diffusion-weighted imaging of the kidney: comparison between simultaneous multi-slice and integrated slice-by-slice shimming echo planar sequence
    Zhang, G.
    Sun, H.
    Qian, T.
    An, J.
    Shi, B.
    Zhou, H.
    Liu, Y.
    Peng, X.
    Chen, L.
    Jin, Z.
    CLINICAL RADIOLOGY, 2019, 74 (04) : 325.e1 - 325.e8
  • [7] Diffusion-weighted imaging with simultaneous multi-slice echo-planar technique for the diagnosis of breast magnetic resonance imaging
    Machida, Youichi
    Nomura, Kyoko
    Shimauchi, Akiko
    Kato, Yoshiaki
    Nagatsuka, Machiko
    Fukuma, Eisuke
    JAPANESE JOURNAL OF RADIOLOGY, 2020, 38 (04) : 358 - 364
  • [8] Diffusion-weighted imaging with simultaneous multi-slice echo-planar technique for the diagnosis of breast magnetic resonance imaging
    Youichi Machida
    Kyoko Nomura
    Akiko Shimauchi
    Yoshiaki Kato
    Machiko Nagatsuka
    Eisuke Fukuma
    Japanese Journal of Radiology, 2020, 38 : 358 - 364
  • [9] Improved Spatiotemporal Resolution of Dynamic Susceptibility Contrast Perfusion MRI in Brain Tumors Using Simultaneous Multi-Slice Echo-Planar Imaging
    Chakhoyan, A.
    Leu, K.
    Pope, W. B.
    Cloughesy, T. F.
    Ellingson, B. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (01) : 43 - 45
  • [10] Accelerating multi-slice spatiotemporally encoded MRI with simultaneous echo refocusing
    Luo, Yao
    Zhang, Jun
    Chen, Lin
    Cai, Shuhui
    Cai, Congbo
    JOURNAL OF MAGNETIC RESONANCE, 2018, 296 : 12 - 22