Improving diffusion MRI using simultaneous multi-slice echo planar imaging

被引:274
|
作者
Setsompop, K. [1 ,2 ]
Cohen-Adad, J. [1 ,2 ]
Gagoski, B. A. [3 ]
Raij, T. [1 ,2 ]
Yendiki, A. [1 ,2 ]
Keil, B. [1 ,2 ]
Wedeen, V. J. [1 ,2 ]
Wald, L. L. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Dept Radiol, Charlestown, MA 02129 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
关键词
Diffusion MRI; Simultaneous multi-slice; CAIPIRINHA; Parallel imaging; SPIN-ECHO; SELECTIVE EXCITATION; FIBER ORIENTATION; TENSOR MRI; IMAGES; GRADIENT; EPI; RECONSTRUCTIONS; ARRAYS; SIGNAL;
D O I
10.1016/j.neuroimage.2012.06.033
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In diffusion MRI, simultaneous multi-slice single-shot EPI acquisitions have the potential to increase the number of diffusion directions obtained per unit time, allowing more diffusion encoding in high angular resolution diffusion imaging (HARDI) acquisitions. Nonetheless, unaliasing simultaneously acquired, closely spaced slices with parallel imaging methods can be difficult, leading to high g-factor penalties (i.e., lower SNR). The CAIPIRINHA technique was developed to reduce the g-factor in simultaneous multi-slice acquisitions by introducing interslice image shifts and thus increase the distance between aliased voxels. Because the CAIPIRINHA technique achieved this by controlling the phase of the RF excitations for each line of k-space, it is not directly applicable to single-shot EPI employed in conventional diffusion imaging. We adopt a recent gradient encoding method, which we termed "blipped-CAIPI", to create the image shifts needed to apply CAIPIRINHA to EPI. Here, we use pseudo-multiple replica SNR and bootstrapping metrics to assess the performance of the blipped-CAIPI method in 3 x simultaneous multi-slice diffusion studies. Further, we introduce a novel image reconstruction method to reduce detrimental ghosting artifacts in these acquisitions. We show that data acquisition times for Q-ball and diffusion spectrum imaging (DSI) can be reduced 3-fold with a minor loss in SNR and with similar diffusion results compared to conventional acquisitions. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:569 / 580
页数:12
相关论文
共 50 条
  • [31] Simultaneous multi-slice acquisition using a parallel MR Imaging system
    Tai, Hish-Kuo
    Kuo, Li-Wei
    Lin, Yuan-Pin
    Yao, Ching
    Chen, Jyh-Horng
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1652 - 1655
  • [32] Dynamic 2D self-phase-map Nyquist ghost correction for simultaneous multi-slice echo planar imaging
    Yarach, Uten
    Tung, Yi-Hang
    Setsompop, Kawin
    In, Myung-Ho
    Chatnuntawech, Itthi
    Yakupov, Renat
    Godenschweger, Frank
    Speck, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (04) : 1577 - 1587
  • [33] Simultaneous multi-slice inverse imaging of the human brain
    Hsu, Yi-Cheng
    Chu, Ying-Hua
    Tsai, Shang-Yueh
    Kuo, Wen-Jui
    Chang, Chun-Yuan
    Lin, Fa-Hsuan
    SCIENTIFIC REPORTS, 2017, 7
  • [34] Diffusion-weighted imaging of the head and neck: comparison between integrated slice-specific dynamic shimming and simultaneous multi-slice readout-segmented echo-planar sequences
    Su, Tong
    Zhu, Xiaoli
    Chen, Yu
    Xu, Zhentan
    Chen, Xingming
    Zhang, Tao
    Zhu, Jinxia
    Liu, Wei
    Wang, Xiaoye
    Zhang, Zhuhua
    Feng, Feng
    Jin, Zhengyu
    DENTOMAXILLOFACIAL RADIOLOGY, 2024, 54 (01) : 35 - 42
  • [35] Simultaneous multi-slice inverse imaging of the human brain
    Yi-Cheng Hsu
    Ying-Hua Chu
    Shang-Yueh Tsai
    Wen-Jui Kuo
    Chun-Yuan Chang
    Fa-Hsuan Lin
    Scientific Reports, 7
  • [36] IMPROVED SIMULTANEOUS MULTI-SLICE IMAGING FOR PERFUSION CARDIAC MRI USING OUTER VOLUME SUPPRESSION AND REGULARIZED RECONSTRUCTION
    Demirel, Omer Burak
    Weingartner, Sebastian
    Moeller, Steen
    Akcakaya, Mehmet
    2020 IEEE 17TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2020), 2020, : 1954 - 1957
  • [37] Feasibility study of dual-accelerated simultaneous multi-slice imaging in diffusion tensor imaging of glioma
    He, Yakun
    Chen, Xiaoyu
    Yi, Siqing
    Wang, Min
    Ren, Jin
    Zhou, Peng
    Deng, Heping
    FRONTIERS IN ONCOLOGY, 2024, 14
  • [38] In Vivo MR Elastography of Aortic Stiffness Using Multi-Slice Spin-Echo Echo Planar Imaging Sequence: A Comparison to Gradient Recalled Echo Sequence
    Dong, H.
    Jin, N.
    White, R.
    Kolipaka, A.
    MEDICAL PHYSICS, 2022, 49 (06) : E476 - E476
  • [39] Whole-tumor apparent diffusion coefficient (ADC) analyses of breast lesions based on simultaneous multi-slice readout-segmented echo-planar diffusion-weighted imaging
    Li, Xue
    Zhu, Hong
    Sun, Kun
    Chai, Weimin
    Liu, Wei
    Grimm, Robert
    Fu, Caixia
    Yan, Fuhua
    MAGNETIC RESONANCE IMAGING, 2022, 94 : 119 - 126
  • [40] Maximum Intensity Projection (MIP) Imaging Using Multi-Slice Cine MRI
    Adamson, J.
    Chang, Z.
    Wang, Z.
    Yin, F.
    Cai, J.
    MEDICAL PHYSICS, 2010, 37 (06)