Fast MR thermometry using an echo-shifted sequence with simultaneous multi-slice imaging

被引:8
|
作者
Peng, Yuhong [1 ,2 ,3 ]
Zou, Chao [2 ]
Qiao, Yangzi [2 ]
Tie, Changjun [2 ]
Wan, Qian [2 ]
Jiang, Rui [2 ,4 ]
Cheng, Chuanli [2 ,4 ]
Liang, Dong [2 ]
Zheng, Hairong [2 ]
Li, Faqi [1 ,3 ]
Liu, Xin [2 ]
机构
[1] Chongqing Med Univ, Chongqing & Minist Sci & Technol, State Key Lab Ultrasound Engn Med, Chongqing Key Lab Biomed Engn,Coll Biomed Engn, 153 Box,1 Yixueyuan Rd, Chongqing 400016, Peoples R China
[2] Chinese Acad Sci, Shenzhen Inst Adv Technol, Paul C Lauterbur Res Ctr Biomed Imaging, 1068 Xueyuan Blvd, Shenzhen 518055, Guangdong, Peoples R China
[3] Chongqing Collaborat Innovat Ctr Minimally Invas, Chongqing 400016, Peoples R China
[4] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen 518055, Guangdong, Peoples R China
关键词
Magnetic resonance imaging; Thermometry; Simultaneous multi-slice imaging; Echo-shifted sequence; SIGNAL-TO-NOISE; ABDOMINAL ORGANS; HUMAN BRAIN; IN-VIVO; RECONSTRUCTION; PHASE; HIFU; ABLATION; CANCER; SENSITIVITY;
D O I
10.1007/s10334-018-0692-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeReal-time monitoring is important for the safety and effectiveness of high-intensity focused ultrasound (HIFU) therapy. Magnetic resonance imaging is the preferred imaging modality for HIFU monitoring, with its unique capability of temperature imaging. For real-time temperature imaging, higher temporal resolution and larger spatial coverage are needed. In this study, a sequence based on the echo-shifted RF-spoiled gradient echo (GRE) with simultaneous multi-slice (SMS) imaging was designed for fast temperature imaging.MethodsA phantom experiment was conducted to evaluate the accuracy of the echo-shifted sequence using a fluorescent fiber thermometer as reference. The temperature uncertainty of the echo-shifted sequence was compared with the traditional GRE sequence at room temperature through the ex vivo porcine muscle. Finally, the ex vivo porcine liver tissue experiment using HIFU heating was performed to demonstrate that the spatial coverage was increased without decreasing temporal resolution.ResultsThe echo-shifted sequence had a better temperature uncertainty performance compared with the traditional GRE sequence with the same temporal resolution. The ex vivo heating experiment confirmed that by combining the SMS technique and echo-shifted sequence, the spatial coverage was increased without decreasing the temporal resolution while maintaining high temperature measurement precision.ConclusionThe proposed technique was validated as an effective real-time method for monitoring HIFU therapy.
引用
收藏
页码:771 / 779
页数:9
相关论文
共 50 条
  • [41] Accelerated Myocardial Viability Imaging Using Both Simultaneous Multi-Slice and Partially Parallel Acquisition
    Zhang, Zhehao
    Sun, Wenbo
    Zheng, Yuan
    Xu, Jian
    Du, Yiping
    Chen, Qun
    2018 5TH INTERNATIONAL CONFERENCE ON BIOMEDICAL AND BIOINFORMATICS ENGINEERING (ICBBE 2018), 2018, : 75 - 81
  • [42] Improved Spatiotemporal Resolution of Dynamic Susceptibility Contrast Perfusion MRI in Brain Tumors Using Simultaneous Multi-Slice Echo-Planar Imaging
    Chakhoyan, A.
    Leu, K.
    Pope, W. B.
    Cloughesy, T. F.
    Ellingson, B. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (01) : 43 - 45
  • [43] Whole-head rapid fMRI acquisition using echo-shifted magnetic resonance inverse imaging
    Chang, Wei-Tang
    Nummenmaa, Aapo
    Witzel, Thomas
    Ahveninen, Jyrki
    Huang, Samantha
    Tsai, Kevin Wen-Kai
    Chu, Ying-Hua
    Polimeni, Jonathan R.
    Belliveau, John W.
    Lin, Fa-Hsuan
    NEUROIMAGE, 2013, 78 : 325 - 338
  • [44] Multi-slice echo-planar spectroscopic MR imaging provides both global and local metabolite measures in multiple sclerosis
    Mathiesen, HK
    Tscherning, T
    Sorensen, PS
    Larsson, HBW
    Rostrup, E
    Paulson, OB
    Hanson, LG
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (04) : 750 - 759
  • [45] Simultaneous multi-slice MR imaging of the hip at 3T to reduce acquisition times and maintain image quality
    Haraikawa, Mayuko
    Suzuki, Masashi
    Inoue, Kaiji
    Kozawa, Eito
    Tanaka, Junji
    Niitsu, Mamoru
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [46] Is simultaneous multi-slice readout-segmented echo-planar imaging valuable for predicting molecular subtypes of breast cancer?
    Li, Xue
    Zhu, Hong
    Sun, Kun
    Chai, Weimin
    Fu, Caixia
    Yan, Fuhua
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 150
  • [47] Whole-Body Diffusion Imaging Applying Simultaneous Multi-Slice Excitation
    Kenkel, D.
    Wurnig, M. C.
    Filli, L.
    Ulbrich, E. J.
    Runge, V. M.
    Beck, T.
    Boss, A.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (04): : 381 - 388
  • [48] Enhancement of the low resolution image quality using randomly sampled data for multi-slice MR imaging
    Pang, Yong
    Yu, Baiying
    Zhang, Xiaoliang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2014, 4 (02) : 136 - 144
  • [49] Accelerating acquisition of readout-segmented echo planar imaging with a simultaneous multi-slice (SMS) technique for diagnosing breast lesions
    Hu, Yiqi
    Zhan, Chenao
    Yang, Zhenlu
    Zhang, Xiaoyong
    Zhang, Huiting
    Liu, Wei
    Xia, Liming
    Ai, Tao
    EUROPEAN RADIOLOGY, 2021, 31 (05) : 2667 - 2676
  • [50] Accelerating acquisition of readout-segmented echo planar imaging with a simultaneous multi-slice (SMS) technique for diagnosing breast lesions
    Yiqi Hu
    Chenao Zhan
    Zhenlu Yang
    Xiaoyong Zhang
    Huiting Zhang
    Wei Liu
    Liming Xia
    Tao Ai
    European Radiology, 2021, 31 : 2667 - 2676