Fast MR thermometry using an echo-shifted sequence with simultaneous multi-slice imaging

被引:8
|
作者
Peng, Yuhong [1 ,2 ,3 ]
Zou, Chao [2 ]
Qiao, Yangzi [2 ]
Tie, Changjun [2 ]
Wan, Qian [2 ]
Jiang, Rui [2 ,4 ]
Cheng, Chuanli [2 ,4 ]
Liang, Dong [2 ]
Zheng, Hairong [2 ]
Li, Faqi [1 ,3 ]
Liu, Xin [2 ]
机构
[1] Chongqing Med Univ, Chongqing & Minist Sci & Technol, State Key Lab Ultrasound Engn Med, Chongqing Key Lab Biomed Engn,Coll Biomed Engn, 153 Box,1 Yixueyuan Rd, Chongqing 400016, Peoples R China
[2] Chinese Acad Sci, Shenzhen Inst Adv Technol, Paul C Lauterbur Res Ctr Biomed Imaging, 1068 Xueyuan Blvd, Shenzhen 518055, Guangdong, Peoples R China
[3] Chongqing Collaborat Innovat Ctr Minimally Invas, Chongqing 400016, Peoples R China
[4] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen 518055, Guangdong, Peoples R China
关键词
Magnetic resonance imaging; Thermometry; Simultaneous multi-slice imaging; Echo-shifted sequence; SIGNAL-TO-NOISE; ABDOMINAL ORGANS; HUMAN BRAIN; IN-VIVO; RECONSTRUCTION; PHASE; HIFU; ABLATION; CANCER; SENSITIVITY;
D O I
10.1007/s10334-018-0692-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeReal-time monitoring is important for the safety and effectiveness of high-intensity focused ultrasound (HIFU) therapy. Magnetic resonance imaging is the preferred imaging modality for HIFU monitoring, with its unique capability of temperature imaging. For real-time temperature imaging, higher temporal resolution and larger spatial coverage are needed. In this study, a sequence based on the echo-shifted RF-spoiled gradient echo (GRE) with simultaneous multi-slice (SMS) imaging was designed for fast temperature imaging.MethodsA phantom experiment was conducted to evaluate the accuracy of the echo-shifted sequence using a fluorescent fiber thermometer as reference. The temperature uncertainty of the echo-shifted sequence was compared with the traditional GRE sequence at room temperature through the ex vivo porcine muscle. Finally, the ex vivo porcine liver tissue experiment using HIFU heating was performed to demonstrate that the spatial coverage was increased without decreasing temporal resolution.ResultsThe echo-shifted sequence had a better temperature uncertainty performance compared with the traditional GRE sequence with the same temporal resolution. The ex vivo heating experiment confirmed that by combining the SMS technique and echo-shifted sequence, the spatial coverage was increased without decreasing the temporal resolution while maintaining high temperature measurement precision.ConclusionThe proposed technique was validated as an effective real-time method for monitoring HIFU therapy.
引用
收藏
页码:771 / 779
页数:9
相关论文
共 50 条
  • [31] Diffusion-weighted imaging with simultaneous multi-slice echo-planar technique for the diagnosis of breast magnetic resonance imaging
    Youichi Machida
    Kyoko Nomura
    Akiko Shimauchi
    Yoshiaki Kato
    Machiko Nagatsuka
    Eisuke Fukuma
    Japanese Journal of Radiology, 2020, 38 : 358 - 364
  • [32] Inter-slice leakage and intra-slice aliasing in simultaneous multi-slice echo-planar images
    Carolyn Beth McNabb
    Michael Lindner
    Shan Shen
    Laura Grace Burgess
    Kou Murayama
    Tom Johnstone
    Brain Structure and Function, 2020, 225 : 1153 - 1158
  • [33] AI - Parallel imaging and simultaneous multi-slice MRI of the knee joint
    Graewert, Stephanie
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2023, 195 (07): : 576 - 577
  • [34] Segmented simultaneous multi-slice diffusion weighted imaging with generalized trajectories
    Herbst, Michael
    Deng, Weiran
    Ernst, Thomas
    Stenger, V. Andrew
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (04) : 1476 - 1481
  • [35] Functional imaging of the kidneys using multi-slice CT
    Fleiter, TR
    Schmid, FT
    Boll, DT
    Goerich, J
    Brambs, H
    RADIOLOGY, 2000, 217 : 106 - 107
  • [36] Hyperpolarized 129Xe multi-slice imaging of the human brain using a 3D gradient echo pulse sequence
    Grynko, Vira
    Shepelytskyi, Yurii
    Li, Tao
    Hassan, Ayman
    Granberg, Karl
    Albert, Mitchell S.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (06) : 3175 - 3181
  • [37] A MULTI-SLICE GRADIENT SEQUENCE FOR CONTRAST ENHANCED MR DIAGNOSIS OF INTRACRANIAL TUMORS
    SCHORNER, W
    SANDER, B
    KORNMESSER, W
    LANIADO, M
    NAKAMURA, T
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1988, 148 (06): : 665 - 673
  • [38] 3-DIMENSIONAL FUNCTIONAL IMAGING OF HUMAN BRAIN USING ECHO-SHIFTED FLASH MRI
    DUYN, JH
    MATTAY, VS
    SEXTON, RH
    SOBERING, GS
    BARRIOS, FA
    LIU, GY
    FRANK, JA
    WEINBERGER, DR
    MOONEN, CTW
    MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (01) : 150 - 155
  • [39] Simultaneous multi-slice MR imaging of the hip at 3 T to reduce acquisition times and maintain image quality
    Mayuko Haraikawa
    Masashi Suzuki
    Kaiji Inoue
    Eito Kozawa
    Junji Tanaka
    Mamoru Niitsu
    BMC Musculoskeletal Disorders, 19
  • [40] Novel Technique to Measure Pulse Wave Velocity in Brain Vessels Using a Fast Simultaneous Multi-Slice Excitation Magnetic Resonance Sequence
    Jung, Ju-Yeon
    Lee, Yeong-Bae
    Kang, Chang-Ki
    SENSORS, 2021, 21 (19)