Rotational method simplifies 3-dimensional measurement of left atrial appendage dimensions during transesophageal echocardiography

被引:9
|
作者
Yosefy, Chaim [1 ,3 ]
Azhibekov, Yulia [2 ]
Brodkin, Boris [1 ]
Khalameizer, Vladimir [1 ]
Katz, Amos [1 ]
Laish-Farkash, Avishag [1 ]
机构
[1] Ben Gurion Univ Negev, Barzilai Med Ctr, Dept Cardiol, Ashqelon, Israel
[2] Ben Gurion Univ Negev, Barzilai Med Ctr, Dept Imaging, Ashqelon, Israel
[3] Barzilai Govt Hosp, Noninvas Cardiol Unit, IL-78306 Ashqelon, Israel
来源
CARDIOVASCULAR ULTRASOUND | 2016年 / 14卷
关键词
3-dimensional transesophageal echocardiography; Left atrial appendage; Imaging; Computed tomography; Rotation; TRANSTHORACIC ECHOCARDIOGRAPHY; FIBRILLATION; TIME; OCCLUSION; CLOSURE; MORPHOLOGY; STROKE; PREVENTION; PLACEMENT; THROMBUS;
D O I
10.1186/s12947-016-0079-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Not all echo laboratories have the capability of measuring direct online 3D images, but do have the capability of turning 3D images into 2D ones "online" for bedside measurements. Thus, we hypothesized that a simple and rapid rotation of the sagittal view (green box, x-plane) that shows all needed left atrial appendage (LAA) number of lobes, orifice area, maximal and minimal diameters and depth parameters on the 3D transesophageal echocardiography (3DTEE) image and LAA measurements after turning the images into 2D (Rotational 3DTEE/"Yosefy Rotation") is as accurate as the direct measurement on real-time-3D image (RT3DTEE). Methods: We prospectively studied 41 consecutive patients who underwent a routine TEE exam, using QLAB 10 Application on EPIQ7 and IE33 3D-Echo machine (BORTHEL Phillips) between 01/2013 and 12/2015. All patients underwent 64-slice CT before pulmonary vein isolation or for workup of pulmonary embolism. LAA measurements were compared between RT3DTEE and Rotational 3DTEE versus CT. Results: Rotational 3DTEE measurements of LAA were not statistically different from RT3DTEE and from CT regarding: number of lobes (1.6 +/- 0.7, 1.6 +/- 0.6, and 1.4 +/- 0.6, respectively, p = NS for all); internal area of orifice (3.1 +/- 0.6, 3.0 +/- 0.7, and 3.3 +/- 1.5 cm(2), respectively, p = NS for all); maximal LAA diameter (24.8 +/- 4.5, 24.6 +/- 5.0, and 24.9 +/- 5.8 mm, respectively, p = NS for all); minimal LAA diameter (16.4 +/- 3.4, 16.7 +/- 3.3, and 17.0 +/- 4.4 mm, respectively, p=NS for all), and LAA depth (20.0 +/- 2.1, 19.8 +/- 2.2, and 21.7 +/- 6.9 mm, respectively, p=NS for all). Conclusion: Rotational 3DTEE method for assessing LAA is a simple, rapid and feasible method that has accuracy similar to that of RT3DTEE and CT. Thus, rotational 3DTEE ("Yosefy rotation") may facilitate LAA closure procedure by choosing the appropriate device size.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Evaluation of the left atrial appendage by real time three-dimensional transesophageal echocardiography online
    Zhang, Juan
    Cui, Cun-Ying
    Huang, Dan-Qing
    Liu, Yuan-Yuan
    Qin, Yun-Yun
    Zhang, Lian-Zhong
    Liu, Lin
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2018, 35 (07): : 991 - 998
  • [42] Validation study of new left atrial appendage closure device measurement by two-dimensional and three-dimensional transesophageal echocardiography
    Ono, Sachiyo
    Maruo, Takeshi
    Kubo, Shunsuke
    Kadota, Kazushige
    JOURNAL OF ECHOCARDIOGRAPHY, 2024, 22 (01) : 16 - 24
  • [43] Assessment of left atrial appendage by live three-dimensional echocardiography: Early experience and comparison with transesophageal echocardiography
    Agoston, I
    Xie, TR
    Tiller, FL
    Rahman, AM
    Ahmad, M
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2006, 23 (02): : 127 - 132
  • [44] Assessment of the Left Atrial Appendage using Real-time Three Dimensional Transesophageal Echocardiography
    Bai Wenjuan
    Chen Zhongxiu
    Wang Hui
    Wei Xin
    Rao Li
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (16) : C227 - C227
  • [45] Assessment of the left atrial appendage using real-time three dimensional transesophageal echocardiography
    Bai, Wenjuan
    Chen, Zhongxiu
    Wang, Hui
    Wei, Xin
    Rao, Li
    CARDIOLOGY, 2014, 129 : 128 - 128
  • [46] Validation study of new left atrial appendage closure device measurement by two-dimensional and three-dimensional transesophageal echocardiography
    Sachiyo Ono
    Takeshi Maruo
    Shunsuke Kubo
    Kazushige Kadota
    Journal of Echocardiography, 2024, 22 : 16 - 24
  • [47] The Process of Left Atrial Appendage Dysfunction Evaluated by 3D Transesophageal Echocardiography
    Haruka, Fujimaki
    Hama, Yoshiyuki
    Sekine, Tai
    Fujimoto, Yoshihide
    Yamamoto, Masashi
    Himi, Toshihide
    CIRCULATION, 2015, 132
  • [48] Evaluation of left atrial appendage functions by transesophageal echocardiography in patients with hyperthyroidis
    Ozkan, Hakan
    Binici, Suleyman
    Tiryakioglu, Selma Kenar
    Basel, M. Cem
    Ari, Hasan
    Tenekecioglu, Erhan
    Bozat, Tahsin
    Koca, M. Vedat
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2006, 34 (02): : 79 - 83
  • [49] Intracardiac versus transesophageal echocardiography for left atrial appendage occlusion with watchman
    Frangieh, Antonio H.
    Alibegovic, Jasmina
    Templin, Christian
    Gaemperli, Oliver
    Obeid, Slayman
    Manka, Robert
    Holy, Erik W.
    Maier, Willibald
    Luscher, Thomas F.
    Binder, Ronald K.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (02) : 331 - 338
  • [50] Reply: Intraoperative transesophageal echocardiography is essential for left atrial appendage closure
    Shen, Ming
    Liu, Gang
    Wei, Shixiong
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (09) : 3458 - 3458