Rotational method simplifies 3-dimensional measurement of left atrial appendage dimensions during transesophageal echocardiography

被引:9
|
作者
Yosefy, Chaim [1 ,3 ]
Azhibekov, Yulia [2 ]
Brodkin, Boris [1 ]
Khalameizer, Vladimir [1 ]
Katz, Amos [1 ]
Laish-Farkash, Avishag [1 ]
机构
[1] Ben Gurion Univ Negev, Barzilai Med Ctr, Dept Cardiol, Ashqelon, Israel
[2] Ben Gurion Univ Negev, Barzilai Med Ctr, Dept Imaging, Ashqelon, Israel
[3] Barzilai Govt Hosp, Noninvas Cardiol Unit, IL-78306 Ashqelon, Israel
来源
CARDIOVASCULAR ULTRASOUND | 2016年 / 14卷
关键词
3-dimensional transesophageal echocardiography; Left atrial appendage; Imaging; Computed tomography; Rotation; TRANSTHORACIC ECHOCARDIOGRAPHY; FIBRILLATION; TIME; OCCLUSION; CLOSURE; MORPHOLOGY; STROKE; PREVENTION; PLACEMENT; THROMBUS;
D O I
10.1186/s12947-016-0079-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Not all echo laboratories have the capability of measuring direct online 3D images, but do have the capability of turning 3D images into 2D ones "online" for bedside measurements. Thus, we hypothesized that a simple and rapid rotation of the sagittal view (green box, x-plane) that shows all needed left atrial appendage (LAA) number of lobes, orifice area, maximal and minimal diameters and depth parameters on the 3D transesophageal echocardiography (3DTEE) image and LAA measurements after turning the images into 2D (Rotational 3DTEE/"Yosefy Rotation") is as accurate as the direct measurement on real-time-3D image (RT3DTEE). Methods: We prospectively studied 41 consecutive patients who underwent a routine TEE exam, using QLAB 10 Application on EPIQ7 and IE33 3D-Echo machine (BORTHEL Phillips) between 01/2013 and 12/2015. All patients underwent 64-slice CT before pulmonary vein isolation or for workup of pulmonary embolism. LAA measurements were compared between RT3DTEE and Rotational 3DTEE versus CT. Results: Rotational 3DTEE measurements of LAA were not statistically different from RT3DTEE and from CT regarding: number of lobes (1.6 +/- 0.7, 1.6 +/- 0.6, and 1.4 +/- 0.6, respectively, p = NS for all); internal area of orifice (3.1 +/- 0.6, 3.0 +/- 0.7, and 3.3 +/- 1.5 cm(2), respectively, p = NS for all); maximal LAA diameter (24.8 +/- 4.5, 24.6 +/- 5.0, and 24.9 +/- 5.8 mm, respectively, p = NS for all); minimal LAA diameter (16.4 +/- 3.4, 16.7 +/- 3.3, and 17.0 +/- 4.4 mm, respectively, p=NS for all), and LAA depth (20.0 +/- 2.1, 19.8 +/- 2.2, and 21.7 +/- 6.9 mm, respectively, p=NS for all). Conclusion: Rotational 3DTEE method for assessing LAA is a simple, rapid and feasible method that has accuracy similar to that of RT3DTEE and CT. Thus, rotational 3DTEE ("Yosefy rotation") may facilitate LAA closure procedure by choosing the appropriate device size.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] INVERTED LEFT ATRIAL APPENDAGE APPEARING AS A LEFT ATRIAL MASS WITH TRANSESOPHAGEAL ECHOCARDIOGRAPHY DURING CARDIAC-SURGERY
    ARONSON, S
    RUO, W
    SAND, M
    ANESTHESIOLOGY, 1992, 76 (06) : 1054 - 1055
  • [32] Atrial Fibrillation Dilates Left Atrial Appendage Assessed by 3-dimentional Transesophageal Echocardiography
    Miki, Yusuke
    Ichimiya, Satoshi
    Ohishi, Hideo
    Aoki, Toshijiro
    Kawamiya, Toshiki
    Ichimiya, Hitoshi
    Uchida, Yasuhiro
    Watanabe, Junji
    Kanashiro, Masaaki
    Ishii, Hideki
    Amano, Tetsuya
    Matsubara, Tatsuaki
    Murohara, Toyoaki
    CIRCULATION, 2014, 130
  • [33] Transthoracic diagnosis of left atrial appendage myxoma by real-time 3-dimensional echocardiography
    Dawson, D
    Jin, XY
    Mitchell, ARJ
    Ormerod, OO
    Becher, HH
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (02) : 192 - 193
  • [34] Giant Aneurysm of the Left Atrial Appendage Detected by Real-Time 3-Dimensional Echocardiography
    Zhang, Peng-Fei
    Zhang, Mei
    Zhang, Wei
    Yao, Gui-Hua
    Wu, Shu-Ming
    Zhang, Yun
    TEXAS HEART INSTITUTE JOURNAL, 2010, 37 (01): : 129 - 130
  • [35] A Pilot Study for Left Atrial Appendage Occlusion Guided by 3-Dimensional Rotational Angiography Alone
    De Potter, Tom
    Chatzikyriakou, Sofia
    Silva, Etel
    Van Camp, Guy
    Penicka, Martin
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (02) : 223 - 224
  • [36] Successful Placement of Left Atrial Appendage Closure Device Is Heavily Dependent on 3-Dimensional Transesophageal Imaging
    Unsworth, Beth
    Sutaria, Nilesh
    Davies, D. Wyn
    Kanagaratnam, Prapa
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (12) : 1283 - 1283
  • [37] A novel Morphological Classification for left atrial appendage by transesophageal echocardiography and its impact in left atrial appendage closure
    Qiao, Zhiqing
    Ge, Heng
    Jiang, Lisheng
    Li, Zheng
    Wang, Xinhua
    Shen, Xuedong
    He, Ben
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (16) : C201 - C201
  • [38] Comparison of left atrial dimensions by transthoracic and transesophageal echocardiography
    Block, M
    Hourigan, L
    Bellows, WH
    Reeves, J
    Romson, JL
    Tran, M
    Pastor, D
    Schiller, N
    Leung, JM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 386A - 386A
  • [39] Comparison of left atrial dimensions by transesophageal and transthoracic echocardiography
    Block, M
    Hourigan, L
    Bellows, WH
    Reeves, J
    Romson, JL
    Tran, M
    Pastor, D
    Schiller, NB
    Leung, JM
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (02) : 143 - 149
  • [40] Left Atrial Appendage Occlusion Procedure: Transesophageal Echocardiography versus Intracardiac Echocardiography-Pro: Transesophageal Echocardiography
    Awadallah, Con Doaa
    Elrifay, Amr
    Awad, Hamdy
    Anam, Karina
    Augostini, Ralph
    Bhandary, Sujatha
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2024, 38 (01) : 320 - 323