Rotational method simplifies 3-dimensional measurement of left atrial appendage dimensions during transesophageal echocardiography

被引:9
|
作者
Yosefy, Chaim [1 ,3 ]
Azhibekov, Yulia [2 ]
Brodkin, Boris [1 ]
Khalameizer, Vladimir [1 ]
Katz, Amos [1 ]
Laish-Farkash, Avishag [1 ]
机构
[1] Ben Gurion Univ Negev, Barzilai Med Ctr, Dept Cardiol, Ashqelon, Israel
[2] Ben Gurion Univ Negev, Barzilai Med Ctr, Dept Imaging, Ashqelon, Israel
[3] Barzilai Govt Hosp, Noninvas Cardiol Unit, IL-78306 Ashqelon, Israel
来源
CARDIOVASCULAR ULTRASOUND | 2016年 / 14卷
关键词
3-dimensional transesophageal echocardiography; Left atrial appendage; Imaging; Computed tomography; Rotation; TRANSTHORACIC ECHOCARDIOGRAPHY; FIBRILLATION; TIME; OCCLUSION; CLOSURE; MORPHOLOGY; STROKE; PREVENTION; PLACEMENT; THROMBUS;
D O I
10.1186/s12947-016-0079-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Not all echo laboratories have the capability of measuring direct online 3D images, but do have the capability of turning 3D images into 2D ones "online" for bedside measurements. Thus, we hypothesized that a simple and rapid rotation of the sagittal view (green box, x-plane) that shows all needed left atrial appendage (LAA) number of lobes, orifice area, maximal and minimal diameters and depth parameters on the 3D transesophageal echocardiography (3DTEE) image and LAA measurements after turning the images into 2D (Rotational 3DTEE/"Yosefy Rotation") is as accurate as the direct measurement on real-time-3D image (RT3DTEE). Methods: We prospectively studied 41 consecutive patients who underwent a routine TEE exam, using QLAB 10 Application on EPIQ7 and IE33 3D-Echo machine (BORTHEL Phillips) between 01/2013 and 12/2015. All patients underwent 64-slice CT before pulmonary vein isolation or for workup of pulmonary embolism. LAA measurements were compared between RT3DTEE and Rotational 3DTEE versus CT. Results: Rotational 3DTEE measurements of LAA were not statistically different from RT3DTEE and from CT regarding: number of lobes (1.6 +/- 0.7, 1.6 +/- 0.6, and 1.4 +/- 0.6, respectively, p = NS for all); internal area of orifice (3.1 +/- 0.6, 3.0 +/- 0.7, and 3.3 +/- 1.5 cm(2), respectively, p = NS for all); maximal LAA diameter (24.8 +/- 4.5, 24.6 +/- 5.0, and 24.9 +/- 5.8 mm, respectively, p = NS for all); minimal LAA diameter (16.4 +/- 3.4, 16.7 +/- 3.3, and 17.0 +/- 4.4 mm, respectively, p=NS for all), and LAA depth (20.0 +/- 2.1, 19.8 +/- 2.2, and 21.7 +/- 6.9 mm, respectively, p=NS for all). Conclusion: Rotational 3DTEE method for assessing LAA is a simple, rapid and feasible method that has accuracy similar to that of RT3DTEE and CT. Thus, rotational 3DTEE ("Yosefy rotation") may facilitate LAA closure procedure by choosing the appropriate device size.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Real time 3-dimensional transesophageal echocardiography is more specific than 2-dimensional TEE in the assessment of left atrial appendage thrombosis
    Marek, Dan
    Vindis, David
    Kocianova, Eva
    BIOMEDICAL PAPERS-OLOMOUC, 2013, 157 (01): : 22 - 26
  • [22] Comparison of Left Atrial Measurements Using 2-and 3-Dimensional Transesophageal Echocardiography
    Kwak, Jenny
    Polito, Andrea
    Majewski, Michael
    Adams, William
    Burcar, Kimberly
    Oftadeh, Mina
    Haske, Michael
    LeVan, Pierre
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (06) : 1518 - 1526
  • [23] Thrombus Attached to the Left Atrial Septal Pouch Assessed on 3-Dimensional Transesophageal Echocardiography
    Kuwaki, Hiroshi
    Takeuchi, Masaaki
    Kaku, Kyoko
    Haruki, Nobuhiko
    Yoshitani, Hidetoshi
    Tamura, Masahito
    Okazaki, Masahiro
    Abe, Haruhiko
    Otsuji, Yutaka
    CIRCULATION JOURNAL, 2011, 75 (09) : 2280 - 2281
  • [24] INTRACARDIAC ECHOCARDIOGRAPHY VERSUS TRANSESOPHAGEAL ECHOCARDIOGRAPHY FOR LEFT ATRIAL APPENDAGE OCCLUSION
    Parekh, Jai
    Saadi, Abdulghani
    Kanmanthareddy, Arun
    Pandya, Jitendra
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1231 - 1231
  • [25] Additional benefit of three-dimensional transesophageal echocardiography for detection of the left atrial and left atrial appendage thrombi
    Chuapai, Y.
    See, O.
    EUROPEAN HEART JOURNAL, 2009, 30 : 632 - 632
  • [26] TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN THE DIAGNOSIS OF ACQUIRED ANEURYSMS OF THE LEFT ATRIAL APPENDAGE
    CULVER, DL
    BEZANTE, GP
    SCHWARZ, KQ
    MELTZER, RS
    CLINICAL CARDIOLOGY, 1993, 16 (02) : 149 - 151
  • [27] INCOMPLETE LIGATION OF THE LEFT ATRIAL APPENDAGE - DIAGNOSIS BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    KATZ, ES
    KRONZON, I
    AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1992, 6 (04): : 262 - 263
  • [28] Intraoperative transesophageal echocardiography is essential for left atrial appendage closure
    Guner, Ezgi G.
    corekcioglu, Busra
    Ulutas, Ahmet E.
    Kalcik, Macit
    Guner, Ahmet
    Erturk, Mehmet
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (01) : 412 - 413
  • [29] Assessment of transesophageal echocardiography to describe left atrial appendage morphology
    Morello, M.
    Anselmino, M. A.
    Jorfida, M.
    Gili, S.
    Perversi, J.
    Frea, S.
    Marra, W. Grosso
    Faletti, R.
    Righi, D.
    Gaita, F.
    EUROPEAN HEART JOURNAL, 2014, 35 : 281 - 281
  • [30] Left Atrial Appendage Occlusion Guided Only by Transesophageal Echocardiography
    Zhao, Jinlong
    Li, Feng
    Zhang, Yueli
    Zhuang, Zhongyun
    Wang, Man
    Fu, Liang
    Ni, Yinkai
    Lu, Zhexin
    Chen, Zonghui
    Zhang, Cheng
    CARDIOLOGY RESEARCH AND PRACTICE, 2019, 2019