Advanced Semiconductor Dosimetry in Radiation Therapy

被引:12
|
作者
Rosenfeld, Anatoly B. [1 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
关键词
Dosimetry; radiation; LINAC; proton therapy; diode; quality assurance; FIELD-EFFECT TRANSISTOR; STEP-AND-SHOOT; DIODE-ARRAY; QUALITY-ASSURANCE; MOSFET DOSIMETRY; DETECTOR SIZE; VERIFICATION; TOMOTHERAPY; IMRT; DEPENDENCE;
D O I
10.1063/1.3576159
中图分类号
O59 [应用物理学];
学科分类号
摘要
Modern radiation therapy is very conformal, resulting in a complexity of delivery that leads to many small radiation fields with steep dose gradients, increasing error probability. Quality assurance in delivery of such radiation fields is paramount and requires real time and high spatial resolution dosimetry. Semiconductor radiation detectors due to their small size, ability to operate in passive and active modes and easy real time multichannel readout satisfy many aspects of in vivo and in a phantom quality assurance in modern radiation therapy. Update on the recent developments and improvements in semiconductor radiation detectors and their application for quality assurance in radiation therapy, based mostly on the developments at the Centre for Medical Radiation Physics (CMRP), University of Wollongong, is presented.
引用
收藏
页码:48 / 74
页数:27
相关论文
共 50 条
  • [31] Film dosimetry for intensity modulated radiation therapy
    Benites-Rengifo, J
    Martínez-Dávalos, A
    Celis, M
    Lárraga, J
    MEDICAL PHYSICS, 2004, 724 : 244 - 248
  • [32] Internal dosimetry for radiation therapy in coronary arteries
    Campos, L
    Stabin, M
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 423 - 426
  • [33] Radiation dosimetry for radionuclide therapy in a nonmyeloablative strategy
    DeNardo, GL
    Siantar, CLH
    DeNardo, SJ
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2002, 17 (01) : 107 - 118
  • [34] Dosimetry challenges and opportunities in modern radiation therapy
    Low, D. A.
    10TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2019, 1305
  • [35] Numerical assessment of radiation binary targeted therapy for HER-2 positive breast cancers:: advanced calculations and radiation dosimetry
    Goncalves-Carralves, Manuel L. Sztejnberg
    Jevremovic, Tatjana
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (14): : 4245 - 4264
  • [36] ADVANCED CONCEPTS FOR SEMICONDUCTOR NUCLEAR RADIATION DETECTORS
    KEMMER, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 45 (1-4): : 247 - 251
  • [37] Benchmark experiment to verify radiation transport calculations for dosimetry in radiation therapy
    Renner, Franziska
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2016, 26 (03): : 209 - 223
  • [38] MOSFET dosimetry for microbeam radiation therapy at the European Synchrotron Radiation Facility
    Bräuer-Krisch, E
    Bravin, A
    Lerch, M
    Rosenfeld, A
    Stepanek, J
    Di Michiel, M
    Laissue, JA
    MEDICAL PHYSICS, 2003, 30 (04) : 583 - 589
  • [39] TLD dosimetry for microbeam radiation therapy at the European Synchrotron Radiation Facility
    Ptaszkiewicz, M.
    Braurer-Kirsch, E.
    Klosowski, M.
    Czopyk, L.
    Olko, P.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 990 - 993
  • [40] Radiation therapy for cervix carcinoma: Benefits of individualized dosimetry
    Foroudi, F
    Bull, CA
    Gebski, V