Internal dosimetry for radiation therapy in coronary arteries

被引:1
|
作者
Campos, L
Stabin, M
机构
[1] Univ Paris 07, Fac Med Xavier Bichat, Lab Chim & Biophys Traceurs, F-75870 Paris 18, France
[2] Univ Fed Pernambuco, Dept Nucl Energy, BR-50740540 Recife, PE, Brazil
[3] Vanderbilt Univ, Dept Radiol & Radiol Sci, Nashville, TN 37232 USA
关键词
D O I
10.1093/oxfordjournals.rpd.a006016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Acute myocardial infarction, which occurs because of the occlusion of one or more coronary arteries, is the most common form of cardiovascular disease. Balloon angioplasty is often used to treat coronary artery occlusion and is less invasive than surgery involving revascularisation of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of re-stenosis after balloon angioplasty is high (approximately 30-50% within the first year after treatment). Intravascular radiation therapy has been used with several types of radiation source, and researchers have observed some Success in decreasing the rate of re-stenosis. In this paper theoretical radiation dose distributions for monoenergetic electrons (with discrete energies) and photons are calculated for blood vessels of diameter 1.5, 3.0 and 4.5 mm with balloon and wire sources using the radiation transport code MCNP4B. Stent sources employing P-32 are also simulated. Advantages and disadvantages of the radionuclides and Source geometries are discussed, as well as issues regarding possible benefits to the patients.
引用
收藏
页码:423 / 426
页数:4
相关论文
共 50 条
  • [1] Internal dosimetry for radiation therapy in coronary arteries
    Campos, L
    Stabin, M
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A423 - A426
  • [2] Internal dosimetry for systemic radiation therapy
    Fisher, DR
    SEMINARS IN RADIATION ONCOLOGY, 2000, 10 (02) : 123 - 132
  • [3] Selective internal radiation therapy dosimetry
    Kennedy, Andrew
    FUTURE ONCOLOGY, 2014, 10 (15) : 77 - 81
  • [4] SELECTIVE INTERNAL RADIATION-THERAPY - VALIDATION OF INTRAOPERATIVE DOSIMETRY
    BURTON, MA
    GRAY, BN
    KELLEHER, DK
    KLEMP, PF
    RADIOLOGY, 1990, 175 (01) : 253 - 255
  • [5] Thoracic radiation therapy and suitability of internal thoracic arteries for myocardial revascularization
    Nasso, G
    Canosa, C
    De Filippo, CM
    Mondugno, P
    Anselmi, A
    Gaudino, M
    Alessandrini, F
    CHEST, 2005, 128 (03) : 1587 - 1592
  • [6] Mouse models for internal radiation dosimetry
    Fisher, DR
    Hui, TE
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (11) : 1969 - 1970
  • [7] Microsphere distributions and small-scale dosimetry in selective internal radiation therapy
    Hogberg, Jonas
    Rizell, Magnus
    Hultborn, Ragnar
    Svensson, Johanna
    Henrikson, Olof
    Molne, Johan
    Gjertsson, Peter
    Bernhardt, Peter
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [8] Coronary dosimetry based on heart CT angiographies for Hodgkin lymphoma radiation therapy
    Moignier, A.
    Derreumaux, S.
    Broggio, D.
    Beaudre, A.
    Girinsky, T.
    Paul, J. F.
    Aubert, B.
    Lefkopoulos, D.
    Deutsch, E.
    Bourhis, J.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S35 - S35
  • [9] Electronic dosimetry in radiation therapy
    Rosenfeld, Anatoly B.
    RADIATION MEASUREMENTS, 2006, 41 : S134 - S153
  • [10] Advances in radiation therapy dosimetry
    Paliwal, Bhudatt
    Tewatia, Dinesh
    JOURNAL OF MEDICAL PHYSICS, 2009, 34 (03) : 108 - 116