Advanced Semiconductor Dosimetry in Radiation Therapy

被引:12
|
作者
Rosenfeld, Anatoly B. [1 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
关键词
Dosimetry; radiation; LINAC; proton therapy; diode; quality assurance; FIELD-EFFECT TRANSISTOR; STEP-AND-SHOOT; DIODE-ARRAY; QUALITY-ASSURANCE; MOSFET DOSIMETRY; DETECTOR SIZE; VERIFICATION; TOMOTHERAPY; IMRT; DEPENDENCE;
D O I
10.1063/1.3576159
中图分类号
O59 [应用物理学];
学科分类号
摘要
Modern radiation therapy is very conformal, resulting in a complexity of delivery that leads to many small radiation fields with steep dose gradients, increasing error probability. Quality assurance in delivery of such radiation fields is paramount and requires real time and high spatial resolution dosimetry. Semiconductor radiation detectors due to their small size, ability to operate in passive and active modes and easy real time multichannel readout satisfy many aspects of in vivo and in a phantom quality assurance in modern radiation therapy. Update on the recent developments and improvements in semiconductor radiation detectors and their application for quality assurance in radiation therapy, based mostly on the developments at the Centre for Medical Radiation Physics (CMRP), University of Wollongong, is presented.
引用
收藏
页码:48 / 74
页数:27
相关论文
共 50 条
  • [21] Fiber dosimetry for radiation therapy validation
    Saxena, I.
    Jozsef, G.
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS VIII, 2008, 6852
  • [22] IN SILICO DOSIMETRY, MONTE CARLO WEB APPLICATIONS FOR SIMULATIONS IN ADVANCED RADIATION THERAPY, RADIATION BIOLOGY AND RADIATION PROTECTION FIELDS.
    Bourhaleb, F.
    Attili, A.
    Russo, G.
    Milian, F. Mas
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S129 - S129
  • [23] Advanced Radiation DOSimetry phantom (ARDOS): a versatile breathing phantom for 4D radiation therapy and medical imaging
    Kostiukhina, Natalia
    Georg, Dietmar
    Rollet, Sofia
    Kuess, Peter
    Sipaj, Andrej
    Andrzejewski, Piotr
    Furtado, Hugo
    Rausch, Ivo
    Lechner, Wolfgang
    Steiner, Elisabeth
    Kertesz, Hunor
    Knaeusl, Barbara
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (20): : 8136 - 8153
  • [24] Gamma-radiation dosimetry with semiconductor CdTe and CdZnTe detectors
    Rybka, AV
    Davydov, LN
    Shlyakhov, IN
    Kutny, VE
    Prokhoretz, IM
    Kutny, DV
    Orobinsky, AN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2): : 147 - 156
  • [25] Dosimetry for Spatially Fractionated Synchrotron Radiation Therapy
    Livingstone, J.
    Adam, J. F.
    Stevenson, A. W.
    Hausermann, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E658 - E658
  • [26] Thermoluminescence dosimetry for quality assurance in radiation therapy
    Kalef-Ezra, JA
    Boziari, A
    Litsas, J
    Tsekeris, P
    Koligliatis, T
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A403 - A405
  • [27] DOSIMETRY - HIGH-ENERGY RADIATION THERAPY
    LANZL, LH
    LAUGHLIN, JS
    SCIENCE, 1967, 158 (3807) : 1499 - &
  • [28] Internal dosimetry for radiation therapy in coronary arteries
    Campos, L
    Stabin, M
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A423 - A426
  • [29] Towards a Personalized Cardiovascular Dosimetry in Radiation Therapy
    Moignier, A.
    Derreumaux, S.
    Broggio, D.
    Girinsky, T.
    Paul, J.
    Beaudre, A.
    Mandin, A.
    Chea, M.
    Franck, D.
    Jenny, C.
    Lefkopoulos, D.
    Mazeron, J.
    Deutsch, E.
    Bourhis, J.
    Aubert, B.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [30] Thermoluminescence dosimetry for quality assurance in radiation therapy
    Kalef-Ezra, JA
    Boziari, A
    Litsas, J
    Tsekeris, P
    Koligliatis, T
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 403 - 405