New retrofit method to improve the thermal performance of natural draft wet cooling towers based on the reconstruction of the aerodynamic field

被引:29
|
作者
Chen, Xuehong [1 ]
Sun, Fengzhong [1 ]
Chen, Youliang [2 ]
Gao, Ming [1 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Jinan 250061, Shandong, Peoples R China
[2] Huadian Elect Power Res Inst, Hangzhou 310000, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Natural draft wet cooling tower; Thermal performance; Air duct; Air deflector; Hot model test; Numerical simulation; COUNTER-FLOW; PREDICTION; SIMULATION;
D O I
10.1016/j.ijheatmasstransfer.2018.12.047
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat transfer deterioration that occurs in the inner rain zone weakens the thermal performance of natural draft wet cooling towers (NDWCTs). Existing NDWCT retrofit methods including the air deflectors and the cross wall have limited effects on this deterioration. In this paper, we propose a new retrofit method in which air ducts are installed in the rain zone and air deflectors are installed around the air inlet to improve the total tower thermal performance. To clarify the effect and mechanism of our retrofit method, a hot test for a NDWCT model is performed under various crosswind velocities, and a 3D numerical model for a NDWCT with air deflectors and air ducts is established and validated. Using the proposed method, the thermal performance of a NDWCT is substantially improved with less crosswind sensitivity. It is found that the flow diversion efficiency of the air deflectors weakens the adverse impact of the ambient crosswind on air inflow of the tower, and the additional ambient air introduced through the air ducts enhances the heat transfer in the central rain zone. Compared with the single effect of the air deflectors or the cross wall, the combined effect of the air ducts and air deflectors is more efficient in improving the thermal performance of NDWCTs. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:671 / 680
页数:10
相关论文
共 47 条
  • [21] Numerical study of the thermal-hydraulic performance of evaporative natural draft cooling towers
    Hawlader, MNA
    Liu, BM
    APPLIED THERMAL ENGINEERING, 2002, 22 (01) : 41 - 59
  • [22] Field test study on thermal and ventilation performance for natural draft wet cooling tower after structural improvement
    Zhang, Zhengqing
    Gao, Ming
    Wang, Mingyong
    Guan, Hongjun
    Dang, Zhigang
    He, Suoying
    Sun, Fengzhong
    APPLIED THERMAL ENGINEERING, 2019, 155 : 305 - 312
  • [23] Numerical analysis on performance of mechanical draft wet cooling towers based on the condensation plume module
    Deng, Weipeng
    Sun, Fengzhong
    APPLIED THERMAL ENGINEERING, 2024, 237
  • [24] A general mathematical model for predicting the thermal performance of natural draft dry cooling towers and extending it to three aligned towers
    Khodakaram-Tafti, Amin
    Golneshan, Ali-Akbar
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2025, 47 (01) : 2790 - 2812
  • [25] A general mathematical model for predicting the thermal performance of natural draft dry cooling towers and extending it to three aligned towers
    Khodakaram-Tafti, Amin
    Golneshan, Ali-Akbar
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2025, 47 (01) : 2790 - 2812
  • [26] Comparison on cooling performance of pre-cooled natural draft dry cooling towers using nozzles spray and wet medium
    Miao, Jiayu
    He, Suoying
    Lu, Yuanwei
    Wu, Yuting
    Wu, Xuehong
    Zhang, Guanhong
    Gao, Ming
    Geng, Zhe
    Zhang, Shuzhen
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 27
  • [27] Evaluating vaporization heat, thermal performance, and efficiency of a natural draft wet cooling tower
    Song, Baohong
    Song, Yu
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2022, 236 (06) : 1183 - 1191
  • [28] COUPLING MODEL AND SOLVING APPROACH FOR PERFORMANCE EVALUATION OF NATURAL DRAFT COUNTER-FLOW WET COOLING TOWERS
    Wang, Wei
    Zeng, Deliang
    Hu, Yong
    Liu, Jizhen
    Niu, Yuguang
    THERMAL SCIENCE, 2016, 20 (01): : 291 - 301
  • [29] Field test of the effect of crosswind on ventilation performance of a natural draft wet cooling tower
    Sun, F. (sfzh@sdu.edu.cn), 2012, Chinese Society for Electrical Engineering (32):
  • [30] Wind Effects and the Challenge to Enhance Thermal Performance of Three Aligned Natural Draft Dry Cooling Towers
    Samad Ghafari
    Ali-Akbar Golneshan
    Iranian Journal of Science and Technology, Transactions of Mechanical Engineering, 2018, 42 : 347 - 354