New retrofit method to improve the thermal performance of natural draft wet cooling towers based on the reconstruction of the aerodynamic field

被引:29
|
作者
Chen, Xuehong [1 ]
Sun, Fengzhong [1 ]
Chen, Youliang [2 ]
Gao, Ming [1 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Jinan 250061, Shandong, Peoples R China
[2] Huadian Elect Power Res Inst, Hangzhou 310000, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Natural draft wet cooling tower; Thermal performance; Air duct; Air deflector; Hot model test; Numerical simulation; COUNTER-FLOW; PREDICTION; SIMULATION;
D O I
10.1016/j.ijheatmasstransfer.2018.12.047
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat transfer deterioration that occurs in the inner rain zone weakens the thermal performance of natural draft wet cooling towers (NDWCTs). Existing NDWCT retrofit methods including the air deflectors and the cross wall have limited effects on this deterioration. In this paper, we propose a new retrofit method in which air ducts are installed in the rain zone and air deflectors are installed around the air inlet to improve the total tower thermal performance. To clarify the effect and mechanism of our retrofit method, a hot test for a NDWCT model is performed under various crosswind velocities, and a 3D numerical model for a NDWCT with air deflectors and air ducts is established and validated. Using the proposed method, the thermal performance of a NDWCT is substantially improved with less crosswind sensitivity. It is found that the flow diversion efficiency of the air deflectors weakens the adverse impact of the ambient crosswind on air inflow of the tower, and the additional ambient air introduced through the air ducts enhances the heat transfer in the central rain zone. Compared with the single effect of the air deflectors or the cross wall, the combined effect of the air ducts and air deflectors is more efficient in improving the thermal performance of NDWCTs. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:671 / 680
页数:10
相关论文
共 47 条
  • [31] Wind Effects and the Challenge to Enhance Thermal Performance of Three Aligned Natural Draft Dry Cooling Towers
    Ghafari, Samad
    Golneshan, Ali-Akbar
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF MECHANICAL ENGINEERING, 2018, 42 (04) : 347 - 354
  • [32] Three-dimensional numerical study on thermal performance in a natural draft wet cooling tower
    Zheng, Shuihua
    Jin, Tai
    Fan, Jianren
    ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 169 - +
  • [33] Effect of Thermal Storage Layer Shape on Cooling Performance of Solar-Enhanced Natural-Draft Dry Cooling Towers
    He S.
    Wang R.
    Zhang Z.
    Yan M.
    Liu Y.
    Gao M.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2021, 54 (04): : 405 - 410
  • [34] Performance analysis and multi-objective optimization of mechanical draft wet cooling towers based on water saving, plume and cooling characteristics
    Deng, Weipeng
    Sun, Fengzhong
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 196
  • [35] A performance enhancement of a natural draft dry cooling tower in crosswind via inlet flow field reconstruction
    Wang, Weiliang
    Lyu, Junfu
    Zhang, Hai
    Liu, Qing
    Yue, Guangxi
    Ni, Weidou
    ENERGY AND BUILDINGS, 2018, 164 : 121 - 130
  • [36] Effect of change factors on evaporation loss based on cold end system in natural draft counter-flow wet cooling towers
    Yuan, Wei
    Sun, Fengzhong
    Liu, Ruqing
    Chen, Xuehong
    Li, Ying
    JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2021, 16 (02) : 1 - 10
  • [37] Performance Analyses of Counter-Flow Closed Wet Cooling Towers Based on a Simplified Calculation Method
    Wei, Xiaoqing
    Li, Nianping
    Peng, Jinqing
    Cheng, Jianlin
    Hu, Jinhua
    Wang, Meng
    ENERGIES, 2017, 10 (03):
  • [38] A new natural draft dry cooling tower with improved thermal performance during windy condition
    Goodarzi, M.
    Maryamnegari, S. Moradi
    APPLIED THERMAL ENGINEERING, 2018, 139 : 341 - 351
  • [39] Numerical study on heat and mass transfer performance of a natural draft wet cooling tower based on baffle optimization
    Li, Yaode
    Wu, Yanyu
    Zhong, Yi
    Zhang, Sannan
    APPLIED THERMAL ENGINEERING, 2024, 245
  • [40] Proposing a new technique to enhance thermal performance and reduce structural design wind loads for natural drought cooling towers
    Goudarzi, Mohammad Ali
    ENERGY, 2013, 62 : 164 - 172