Sensitivity Enhancement of Leakage Current Microsensor for Detection of Target Protein by Using Protein Denaturant

被引:0
|
作者
Lorchirachoonkul, P. [1 ]
Yamashita, K. [1 ]
Noda, M. [1 ]
Shimanouchi, T. [2 ]
Umakoshi, H. [2 ]
Kuboi, R. [2 ]
机构
[1] Kyoto Inst Technol, Grad Sch Sci & Technol, Kyoto 606, Japan
[2] Osaka Univ, Grad Sch Engn Sci, Suita, Osaka 5608531, Japan
来源
基金
日本学术振兴会;
关键词
STRESS CONDITIONS;
D O I
10.1109/ICSENS.2010.5690730
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have developed a highly-sensitive leakage current microsensor by using 1,2-dipalmitoyl-sn-glycero-3-phosphocholline (DPPC) liposome entrapping K-4[Fe(CN)(6)] solution to detect existence of biomolecules especially proteins and their dynamic conditions. In this work, the addition of guanidinium hydrochloride (GuHCl) as protein denaturant successfully leads a prominent improvement in sensitivity by 129-fold of magnitude, although target protein, which is carbonic anhydrase from bovine (CAB), weakly interacts with liposome under the normal condition. Moreover, we can use it to evaluate the conformation state of CAB protein such as 'Native', 'Molten-Globule' and 'Unfold' states and we can use this leakage current microsensor to detect other protein that do not have large interaction with the liposome.
引用
收藏
页码:1056 / 1059
页数:4
相关论文
共 50 条
  • [1] Sensitivity Enhancement of Leakage Current Microsensor for Detection of Target Protein by Using Protein Denaturant
    Noda, Minoru
    Lorchirachoonkul, Prinya
    Shimanouchi, Toshinori
    Yamashita, Kaoru
    Umakoshi, Hiroshi
    Kuboi, Ryouichi
    IEEE SENSORS JOURNAL, 2011, 11 (11) : 2749 - 2755
  • [2] A Highly-Sensitive Leakage Current Microsensor by Using Denaturant: Detection of Target Protein by DPPC Liposome
    Lorchirachoonkul, P.
    Shimanouchi, T.
    Yamashita, K.
    Umakoshi, H.
    Kuboi, R.
    Noda, M.
    EUROSENSORS XXIV CONFERENCE, 2010, 5 : 812 - 815
  • [3] A Protein Microsensor by Detection of Leakage Current from Interaction between an Electrolyte-Entrapping Liposome and Protein
    Noda, M.
    Asai, T.
    Shimanouchi, T.
    Yamashita, K.
    Umakoshi, H.
    Okuyama, M.
    Kuboi, R.
    PROCEEDINGS OF THE EUROSENSORS XXIII CONFERENCE, 2009, 1 (01): : 1295 - +
  • [4] A Leakage Current Microsensor for Detection of Interaction between an Electrolyte-Entrapping Liposome and Protein
    Noda, Minoru
    Asai, Takeshi
    Yamashita, Kaoru
    Shimanouchi, Toshinori
    Umakoshi, Hiroshi
    Okuyama, Masanori
    Kuboi, Ryouichi
    2009 IEEE SENSORS, VOLS 1-3, 2009, : 1883 - +
  • [5] New Planar-Type Leakage Current and Impedance Microsensor for Detection of Interaction between Electrolyte-Entrapping Liposome and Protein
    Lorchirachoonkul, P.
    Goto, I.
    Shimanouchi, T.
    Yamashita, K.
    Noda, M.
    EUROSENSORS XXV, 2011, 25
  • [6] PARTNERSHIPS TARGET PROTEIN ENHANCEMENT
    不详
    CHEMICAL & ENGINEERING NEWS, 2009, 87 (21) : 16 - 16
  • [7] Enhancement of odorant detection sensitivity by the expression of odorant-binding protein
    Ko, Hwi Jin
    Park, Tai Hyun
    BIOSENSORS & BIOELECTRONICS, 2008, 23 (07): : 1017 - 1023
  • [8] Enhancement of sensitivity of SPR protein microarray using a novel 3D protein immobilization
    Tanaka, Hiroyuki
    Hanasaki, Minako
    Isojima, Tatsushi
    Takeuchi, Hisao
    Shiroya, Toshifumi
    Kawaguchi, Haruma
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 70 (02) : 259 - 265
  • [9] Leakage detection using pressure sensitivity analysis
    Perez, R.
    Puig, V.
    Pascual, J.
    INTEGRATING WATER SYSTEMS, 2010, : 577 - 581
  • [10] Target detection enhancement using Target Motion Discrimination
    Lerro, D
    Bar-Shalom, Y
    1998 IEEE AEROSPACE CONFERENCE PROCEEDINGS, VOL 5, 1998, : 29 - 35