Sensitivity Enhancement of Leakage Current Microsensor for Detection of Target Protein by Using Protein Denaturant

被引:0
|
作者
Lorchirachoonkul, P. [1 ]
Yamashita, K. [1 ]
Noda, M. [1 ]
Shimanouchi, T. [2 ]
Umakoshi, H. [2 ]
Kuboi, R. [2 ]
机构
[1] Kyoto Inst Technol, Grad Sch Sci & Technol, Kyoto 606, Japan
[2] Osaka Univ, Grad Sch Engn Sci, Suita, Osaka 5608531, Japan
来源
2010 IEEE SENSORS | 2010年
基金
日本学术振兴会;
关键词
STRESS CONDITIONS;
D O I
10.1109/ICSENS.2010.5690730
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have developed a highly-sensitive leakage current microsensor by using 1,2-dipalmitoyl-sn-glycero-3-phosphocholline (DPPC) liposome entrapping K-4[Fe(CN)(6)] solution to detect existence of biomolecules especially proteins and their dynamic conditions. In this work, the addition of guanidinium hydrochloride (GuHCl) as protein denaturant successfully leads a prominent improvement in sensitivity by 129-fold of magnitude, although target protein, which is carbonic anhydrase from bovine (CAB), weakly interacts with liposome under the normal condition. Moreover, we can use it to evaluate the conformation state of CAB protein such as 'Native', 'Molten-Globule' and 'Unfold' states and we can use this leakage current microsensor to detect other protein that do not have large interaction with the liposome.
引用
收藏
页码:1056 / 1059
页数:4
相关论文
共 50 条
  • [31] Protein detection using biobarcodes
    Mueller, Uwe R.
    MOLECULAR BIOSYSTEMS, 2006, 2 (10) : 470 - 476
  • [33] Detection of Pancreatitis and Protein-Losing Gastroenteropathy Associated With Systemic Lupus Erythematosus by Protein Leakage Scintigraphy
    Yamada, Hirofumi
    Sugiyama, Takahiro
    Ito, Yasuhiko
    Toriihara, Akira
    JOURNAL OF RHEUMATOLOGY, 2025, 52 (01) : 103 - 104
  • [34] Detection of Drug Binding to a Target Protein Using EVV 2DIR Spectroscopy
    Sowley, Hugh
    Liu, ZhiQiang
    Davies, Julia
    Peach, Robert
    Guo, Rui
    Sim, Sophie
    Long, FengQin
    Holdgate, Geoffrey
    Willison, Keith
    Zhuang, Wei
    Klug, David R.
    JOURNAL OF PHYSICAL CHEMISTRY B, 2019, 123 (17): : 3598 - 3606
  • [35] Sensitivity Analysis of PE Valve Leakage Detection Using Sensor Method
    Qian, Long-Jie
    Yang, Qi-Hua
    Liu, Gang-Hai
    Lin, Xiao-Ping
    INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND MECHANICAL AUTOMATION (ICEEMA 2015), 2015, : 380 - 385
  • [36] Unveiling the Correlation between Protein, Protein Corona, and Target Signal Loss in SERS Detection
    Mi, Shuna
    Hu, Xinyuan
    Yuan, Shaofeng
    Yu, Hang
    Guo, Yahui
    Cheng, Yuliang
    Yao, Weirong
    ANALYTICAL CHEMISTRY, 2024, 96 (49) : 19768 - 19777
  • [37] High-efficiency recovery of target cells using improved yeast display system for detection of protein-protein interactions
    Fukuda, Nobuo
    Ishii, Jun
    Shibasaki, Seiji
    Ueda, Mitsuyoshi
    Fukuda, Hideki
    Kondo, Akihiko
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2007, 76 (01) : 151 - 158
  • [38] ULTRAFAST PROTEIN DETERMINATIONS USING MICROWAVE ENHANCEMENT
    AKINS, RE
    TUAN, RS
    MOLECULAR BIOTECHNOLOGY, 1995, 4 (01) : 17 - 24
  • [39] Signal enhancement of protein arrays using particles
    Preininger, C
    Sauer, U
    PROCEEDINGS OF THE IEEE SENSORS 2004, VOLS 1-3, 2004, : 808 - 809
  • [40] Using small molecules to target protein phosphatases
    Vintonyak, Viktor V.
    Waldmann, Herbert
    Rauh, Daniel
    BIOORGANIC & MEDICINAL CHEMISTRY, 2011, 19 (07) : 2145 - 2155