A novel point of care diagnostic device:: Impedimetric detection of a biomarker in whole blood

被引:3
|
作者
McMurray, Amanda A. [1 ]
Ali, Zulfiqur [7 ]
Kyselovik, Jan [3 ]
Mills, Christopher A. [4 ]
Renault, Nicole Jaffrezic [2 ]
Santha, Hunor [5 ]
Strohhoefer, Christof [6 ]
机构
[1] Fabriam Ctr, Ctr Excellence Nano & Micro Photon Syst, Newcastle Upon Tyne, Tyne & Wear, England
[2] Univ Lyon 1, Lab Analy Chem, F-69622 Villeurbanne, France
[3] Comenius Univ, Bratislava, Slovakia
[4] Bioengn Inst Catalonia IBEC, Nanobioengn Res Lab, Barcelona, Spain
[5] Budapest Univ Technol & Econ, H-1111 Budapest, Hungary
[6] Fraunhofer Gesell Forderung Angew Forschung eV, D-80007 Munich, Germany
[7] Univ Teesside, Sch Sci & Technol, Middlesbrough, Cleveland, England
关键词
D O I
10.1109/IEMBS.2007.4352236
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
There is an unmet medical need for a more reliable and earlier assessment of patients suspected of having a deep vein thrombosis. We describe a novel approach which is developing a highly reliable, accurate, portable and handheld prototype medical diagnostic device to improve radically the speed, accuracy and reliability with which DVT and related blood clotting conditions can be assessed. The device will measure whole blood concentration of D-dimer, a recognized biomarker of increased blood clotting activity, and through innovation in the development of a novel detection, measurement and reporting system, will offer the opportunity to use the test in the point of care setting. The device combines innovation in antibody bio-engineering for high specificity inummoassay-based diagnostics and nano/micro engineered impedimetric analysis electrodes ncorporating a biocompatible polymer substrate with development of a disposable inicrofluidic manifold specifically enabling diagnostics at the point-of-first-contact.
引用
收藏
页码:115 / +
页数:2
相关论文
共 50 条
  • [31] Diagnostic performance of a rapid, novel, whole blood, point of care high-sensitivity cardiac troponin I assay for myocardial infarction
    Gunsolus, Ian L.
    Schulz, Karen
    Sandoval, Yader
    Smith, Stephen W.
    Lindgren, Brittany
    Okeson, Brynn
    Apple, Fred S.
    CLINICAL BIOCHEMISTRY, 2022, 105 : 70 - 74
  • [32] Spectral and temporal detection of blood bilirubin level using a point-of-care device
    Ndabakuranye, Jean Pierre
    Choy, Kay Weng
    Prawer, Steven
    Ahnood, Arman
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [33] Detection of mpox and other orthopoxviruses using a lateral flow device as a point-of-care diagnostic
    Laidlaw, Stephen M.
    Ulaeto, David
    Lonsdale, Steve
    Clark, Graeme
    Sumner, Rebecca
    Edwards, Thomas
    Adams, Emily
    Logist, Anne-Sophie
    Van Holm, Bram
    de Motes, Carlos Maluquer
    Horby, Peter
    Maes, Piet
    Carroll, Miles W.
    MICROBIOLOGY SPECTRUM, 2025,
  • [34] Fluorescent capillary fill device: a quantitative, whole blood assay system suited to point of care use
    Daniels, PB
    Vessey, JP
    Fletcher, JE
    O'Neill, PM
    Stafford, CG
    Cope, A
    Bacarese-Hamilton, T
    Cookson, AD
    SYSTEMS AND TECHNOLOGIES FOR CLINICAL DIAGNOSTICS AND DRUG DISCOVERY, PROCEEDINGS OF, 1998, 3259 : 28 - 39
  • [35] Plasmonic nanosensors for point-of-care biomarker detection
    Jin, Congran
    Wu, Ziqian
    Molinski, John H.
    Zhou, Junhu
    Ren, Yundong
    Zhang, John X. J.
    MATERIALS TODAY BIO, 2022, 14
  • [36] Point of care diagnostic monitoring in whole blood of Arixtra® (fonadaparinux) and direct factor Xa inhibitors.
    Moskowitz, KA
    Dee, J
    Thelian, D
    BLOOD, 2002, 100 (11) : 277A - 278A
  • [37] Assembly of a Polymer Lab-on-Chip Device for Impedimetric Measurements of D-Dimers in Whole Blood
    Ohlander, A.
    Strohhoefer, C.
    Bock, K.
    Scott, S. M.
    Ali, Z.
    Musil, Peter
    Kyselovic, Jan
    2010 PROCEEDINGS 60TH ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC), 2010, : 1004 - 1009
  • [38] Label-free biomarker detection from whole blood
    Stern E.
    Vacic A.
    Rajan N.K.
    Criscione J.M.
    Park J.
    Ilic B.R.
    Mooney D.J.
    Reed M.A.
    Fahmy T.M.
    Nature Nanotechnology, 2010, 5 (2) : 138 - 142
  • [39] A novel molecular biomarker diagnostic for the early detection of sepsis
    D Venter
    M Thomas
    J Lipman
    B Tang
    A McLean
    R Pascoe
    G Price
    T Nguyen
    R Brandon
    A Sutherland
    Critical Care, 14 (Suppl 2):
  • [40] Label-free biomarker detection from whole blood
    Stern, Eric
    Vacic, Aleksandar
    Rajan, Nitin K.
    Criscione, Jason M.
    Park, Jason
    Ilic, Bojan R.
    Mooney, David J.
    Reed, Mark A.
    Fahmy, Tarek M.
    NATURE NANOTECHNOLOGY, 2010, 5 (02) : 138 - 142