Spectral and temporal detection of blood bilirubin level using a point-of-care device

被引:0
|
作者
Ndabakuranye, Jean Pierre [1 ]
Choy, Kay Weng [2 ]
Prawer, Steven [3 ]
Ahnood, Arman [1 ]
机构
[1] RMIT Univ, Sch Engn, Melbourne, Vic 3038, Australia
[2] Northern Hlth, Northern Pathol Victoria, Epping, Vic 3076, Australia
[3] Univ Melbourne, Sch Phys, Melbourne, Vic 3010, Australia
基金
澳大利亚研究理事会;
关键词
Biosensing; Bilirubin; Biomarker; Blood; Degradation; Point-of-Care; Translational medicine; SYSTEM;
D O I
10.1109/EMBC40787.2023.10340716
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Bilirubin is a biomarker for liver inflammation used to assess liver functions. Its concentration in the blood has been measured using a range of techniques both in clinical and point-of-care settings. Existing point-of-care devices utilize a spectral approach, namely dual-wavelength absorption measurement, to assess the blood bilirubin concentration. This work examines a novel temporal approach based on the photodegradation of bilirubin in the blood sample. It demonstrates that combining photodegradation characteristics with dual-wavelength measurement produces a more accurate technique for measuring blood bilirubin concentration. Tracking the evolution of absorbed light as a function of time represents a low-cost and simple way of improving the accuracy of point-of-care devices for bilirubin measurements.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Clozapine blood level assessment using a point-of-care device: feasibility and reliability
    Kamhi-Nesher, Shiri
    Taub, Sharon
    Halimi, Shikma
    Frenkel, Maria
    Azam, Mahmud
    Bormant, Gil
    Isakov, Helena
    Radzinsky, Dikla
    Weizman, Abraham
    Krivoy, Amir
    THERAPEUTIC ADVANCES IN PSYCHOPHARMACOLOGY, 2022, 12
  • [2] Point-of-Care Device for Quantification of Bilirubin in Skin Tissue
    Alla, Suresh K.
    Huddle, Adam
    Butler, Joshua D.
    Bowman, Peggy S.
    Clark, Joseph F.
    Beyette, Fred R., Jr.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (03) : 777 - 780
  • [3] Point-of-care device for quantification of bilirubin in skin tissue
    Alla, Suresh K.
    Huddle, Adam
    Butler, Joshua D.
    Bowman, Peggy S.
    Clark, Joseph F.
    Beyette Jr., Fred R.
    IEEE Transactions on Biomedical Engineering, 2011, 58 (3 PART 2) : 777 - 780
  • [4] A paper-based point-of-care testing device for the colourimetric estimation of bilirubin in blood sample
    Devi, A. Lakshmi
    Resmi, P. E.
    Pradeep, Aarathi
    Suneesh, P. V.
    Nair, Bipin G.
    Babu, T. G. Satheesh
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 287
  • [5] QUANTIFYING THE ACCUMULATED STRESS LEVEL USING A POINT-OF-CARE TEST DEVICE
    Chen, Chi-Chun
    Lin, Shih-Chi
    Young, Ming-Shing
    Yang, Chin-Lung
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2014, 26 (05):
  • [6] Development of a Point-of-Care Device for the Quantification of Bilirubin in Cerebral Spinal Fluid
    Beyette, Fred R., Jr.
    Booher, Blaine
    Drennan, James
    Carraher, Lee
    Butler, Josh
    Bowman, Peggy
    Clark, Joseph F.
    Wilsey, Philip A.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 915 - 918
  • [7] Point-of-care device for Graves’ disease detection using Infrared Thermography
    Sharma, Vaishali
    Dhingra, Vandana K.
    Kumar, Ashok
    Goswami, Mayank
    e-Journal of Nondestructive Testing, 2022, 27 (11):
  • [8] Plasmonic Point-of-Care Device for Sepsis Biomarker Detection
    Kundu, Souvik
    Tabassum, Shawana
    Kumar, Ratnesh
    IEEE SENSORS JOURNAL, 2021, 21 (17) : 18837 - 18846
  • [9] A Lateral Flow Device for Point-of-Care Detection of Doxorubicin
    Pomili, Tania
    Gatto, Francesca
    Pompa, Pier Paolo
    BIOSENSORS-BASEL, 2022, 12 (10):
  • [10] Microfluidic point-of-care testing device for multiplexed detection of liver function blood markers
    Li, Yingchun
    Cheng, Haobo
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (10): : 5803 - 5817