Detection of mpox and other orthopoxviruses using a lateral flow device as a point-of-care diagnostic

被引:0
|
作者
Laidlaw, Stephen M. [1 ,2 ]
Ulaeto, David [3 ]
Lonsdale, Steve [3 ]
Clark, Graeme [3 ]
Sumner, Rebecca [4 ]
Edwards, Thomas [5 ]
Adams, Emily [5 ,6 ]
Logist, Anne-Sophie [7 ]
Van Holm, Bram [7 ]
de Motes, Carlos Maluquer [4 ]
Horby, Peter [1 ]
Maes, Piet [7 ]
Carroll, Miles W. [1 ,2 ]
机构
[1] Univ Oxford, Pandem Sci Inst PSI, Oxford, England
[2] Univ Oxford, Ctr Human Genet CHG, Oxford, England
[3] DSTL, Salisbury, England
[4] Univ Surrey, Dept Microbial Sci, Guildford, England
[5] Univ Liverpool Liverpool Sch Trop Med, Dept Trop Dis Biol, Liverpool, England
[6] Global Access Diagnost, Bedford, England
[7] Katholieke Univ Leuven, Rega Inst, Lab Clin & Epidemiol Virol, Leuven, Belgium
基金
英国生物技术与生命科学研究理事会;
关键词
mpox; LFD; diagnostics; VACCINIA VIRUS; ASSAY; PROTEINS; IMMUNOGENICITY; IDENTIFICATION; MONKEYPOX; ELISA; HOST;
D O I
10.1128/spectrum.02456-24
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
In 2022, the World Health Organization declared the worldwide outbreak of mpox to be a public health emergency of international concern. The causative monkeypox virus (MPXV) belonged to clade IIb and is transmitted through sexual contact with a low case fatality rate (0.1%), which, together with under-detection, all contributed to a rapid global spread particularly within the MSM (men who have sex with men) community. As MPXV clade II remains circulating worldwide, a new outbreak of the more fatal clade I disease has been declared in Central and East Africa, and remains uncontrolled in part due to the lack of point-of-care (POC) diagnostics for rapid decisions on treatment and self-isolation. To address the lack of POC solutions for mpox, we have designed and evaluated an orthopoxvirus-specific lateral flow device (LFD) that could be used for the diagnosis of mpox. Using an LFD comprising four monoclonal antibodies against the A27 protein, we demonstrate sensitivity to 3 x 10(5) pfu/mL. This sensitivity is expected to be sufficient for the detection of MPXV from lesion sites and may also be sufficient for other sample types such as saliva and urine. We found that the presence of guanidinium thiocyanate, a common ingredient in inactivating viral transport media, masked the LFD antigen, resulting in false negatives. POC diagnosis of mpox may be possible using an LFD to reduce delays arising from sample shipment to centralized laboratory testing facilities. In order to achieve this, our work demonstrates that an LFD-optimized buffer is required, as the sample collection buffer may have a detrimental impact on sensitivity for clinical material. IMPORTANCE Mpox cases have dramatically increased both in traditionally monkeypox virus endemic countries and also worldwide. This increase comes at a time when immunity derived from smallpox vaccination is no longer available. Diagnosis of mpox is complicated due to both disease presentation and the availability of local diagnostic laboratories. The availability of a point-of-care diagnostic tool such as an lateral flow device (LFD) would play an important role to both diagnose and prevent onward transmission. This manuscript provides developers and assessors with key data for defining true sensitivity and specificity of a successful LFD in addition to buffer conditions for sample collection.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] A Lateral Flow Device for Point-of-Care Detection of Doxorubicin
    Pomili, Tania
    Gatto, Francesca
    Pompa, Pier Paolo
    BIOSENSORS-BASEL, 2022, 12 (10):
  • [2] Portable molecular diagnostic platform for rapid point-of-care detection of mpox and other diseases
    Cavuto, Matthew L.
    Malpartida-Cardenas, Kenny
    Pennisi, Ivana
    Pond, Marcus J.
    Mirza, Sohail
    Moser, Nicolas
    Comer, Mark
    Stokes, Isobel
    Eke, Lucy
    Lant, Sian
    Szostak-Lipowicz, Katarzyna M.
    Miglietta, Luca
    Stringer, Oliver W.
    Mantikas, Katerina-Theresa
    Sumner, Rebecca P.
    Bolt, Frances
    Sriskandan, Shiranee
    Holmes, Alison
    Georgiou, Pantelis
    Ulaeto, David O.
    de Motes, Carlos Maluquer
    Rodriguez-Manzano, Jesus
    NATURE COMMUNICATIONS, 2025, 16 (01)
  • [3] Point-of-care coagulation monitoring: first clinical experience using a paper-based lateral flow diagnostic device
    Michael A. Hegener
    Hua Li
    Daewoo Han
    Andrew J. Steckl
    Giovanni M. Pauletti
    Biomedical Microdevices, 2017, 19
  • [4] Point-of-care coagulation monitoring: first clinical experience using a paper-based lateral flow diagnostic device
    Hegener, Michael A.
    Li, Hua
    Han, Daewoo
    Steckl, Andrew J.
    Pauletti, Giovanni M.
    BIOMEDICAL MICRODEVICES, 2017, 19 (03)
  • [5] Rapid and sensitive point-of-care detection of Orthopoxviruses by ABICAP immunofiltration
    Stern, Daniel
    Olson, Victoria A.
    Smith, Scott K.
    Pietraszczyk, Marko
    Miller, Lilija
    Miethe, Peter
    Dorner, Brigitte G.
    Nitsche, Andreas
    VIROLOGY JOURNAL, 2016, 13
  • [6] Rapid and sensitive point-of-care detection of Orthopoxviruses by ABICAP immunofiltration
    Daniel Stern
    Victoria A. Olson
    Scott K. Smith
    Marko Pietraszczyk
    Lilija Miller
    Peter Miethe
    Brigitte G. Dorner
    Andreas Nitsche
    Virology Journal, 13
  • [7] Tapered lateral flow immunoassay based point-of-care diagnostic device for ultrasensitive colorimetric detection of dengue NS1
    Kumar, Sanjay
    Bhushan, Pulak
    Krishna, Vinay
    Bhattacharya, Shantanu
    BIOMICROFLUIDICS, 2018, 12 (03):
  • [8] Strategies for developing sensitive and specific nanoparticle-based lateral flow assays as point-of-care diagnostic device
    Soh, Jun Hui
    Chan, Hsi-Min
    Ying, Jackie Y.
    NANO TODAY, 2020, 30
  • [9] A gold nanoparticle-based lateral flow immunoassay for atrazine point-of-care detection using a handhold scanning device as reader
    Tieqiang Sun
    Zehua Xu
    Shuai Yuan
    Xiao Liu
    Zongfen Chen
    Zhenyu Han
    Wentao Liu
    Longxing Fan
    Han Yang
    Zhiwei Qie
    Baoan Ning
    Microchimica Acta, 2022, 189
  • [10] A gold nanoparticle-based lateral flow immunoassay for atrazine point-of-care detection using a handhold scanning device as reader
    Sun, Tieqiang
    Xu, Zehua
    Yuan, Shuai
    Liu, Xiao
    Chen, Zongfen
    Han, Zhenyu
    Liu, Wentao
    Fan, Longxing
    Yang, Han
    Qie, Zhiwei
    Ning, Baoan
    MICROCHIMICA ACTA, 2022, 189 (04)