Detection of mpox and other orthopoxviruses using a lateral flow device as a point-of-care diagnostic

被引:0
|
作者
Laidlaw, Stephen M. [1 ,2 ]
Ulaeto, David [3 ]
Lonsdale, Steve [3 ]
Clark, Graeme [3 ]
Sumner, Rebecca [4 ]
Edwards, Thomas [5 ]
Adams, Emily [5 ,6 ]
Logist, Anne-Sophie [7 ]
Van Holm, Bram [7 ]
de Motes, Carlos Maluquer [4 ]
Horby, Peter [1 ]
Maes, Piet [7 ]
Carroll, Miles W. [1 ,2 ]
机构
[1] Univ Oxford, Pandem Sci Inst PSI, Oxford, England
[2] Univ Oxford, Ctr Human Genet CHG, Oxford, England
[3] DSTL, Salisbury, England
[4] Univ Surrey, Dept Microbial Sci, Guildford, England
[5] Univ Liverpool Liverpool Sch Trop Med, Dept Trop Dis Biol, Liverpool, England
[6] Global Access Diagnost, Bedford, England
[7] Katholieke Univ Leuven, Rega Inst, Lab Clin & Epidemiol Virol, Leuven, Belgium
基金
英国生物技术与生命科学研究理事会;
关键词
mpox; LFD; diagnostics; VACCINIA VIRUS; ASSAY; PROTEINS; IMMUNOGENICITY; IDENTIFICATION; MONKEYPOX; ELISA; HOST;
D O I
10.1128/spectrum.02456-24
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
In 2022, the World Health Organization declared the worldwide outbreak of mpox to be a public health emergency of international concern. The causative monkeypox virus (MPXV) belonged to clade IIb and is transmitted through sexual contact with a low case fatality rate (0.1%), which, together with under-detection, all contributed to a rapid global spread particularly within the MSM (men who have sex with men) community. As MPXV clade II remains circulating worldwide, a new outbreak of the more fatal clade I disease has been declared in Central and East Africa, and remains uncontrolled in part due to the lack of point-of-care (POC) diagnostics for rapid decisions on treatment and self-isolation. To address the lack of POC solutions for mpox, we have designed and evaluated an orthopoxvirus-specific lateral flow device (LFD) that could be used for the diagnosis of mpox. Using an LFD comprising four monoclonal antibodies against the A27 protein, we demonstrate sensitivity to 3 x 10(5) pfu/mL. This sensitivity is expected to be sufficient for the detection of MPXV from lesion sites and may also be sufficient for other sample types such as saliva and urine. We found that the presence of guanidinium thiocyanate, a common ingredient in inactivating viral transport media, masked the LFD antigen, resulting in false negatives. POC diagnosis of mpox may be possible using an LFD to reduce delays arising from sample shipment to centralized laboratory testing facilities. In order to achieve this, our work demonstrates that an LFD-optimized buffer is required, as the sample collection buffer may have a detrimental impact on sensitivity for clinical material. IMPORTANCE Mpox cases have dramatically increased both in traditionally monkeypox virus endemic countries and also worldwide. This increase comes at a time when immunity derived from smallpox vaccination is no longer available. Diagnosis of mpox is complicated due to both disease presentation and the availability of local diagnostic laboratories. The availability of a point-of-care diagnostic tool such as an lateral flow device (LFD) would play an important role to both diagnose and prevent onward transmission. This manuscript provides developers and assessors with key data for defining true sensitivity and specificity of a successful LFD in addition to buffer conditions for sample collection.
引用
收藏
页数:15
相关论文
共 50 条
  • [11] Evaluation of a Rapid Lateral Flow Point-of-Care Test for Detection of Cryptosporidium
    Fleece, Molly E.
    Heptinstall, Jack
    Khan, Shaila S.
    Kabir, Mamum
    Herbein, Joel
    Haque, Rashidul
    Petri, William A., Jr.
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2016, 95 (04): : 840 - 841
  • [12] The cryptococcal antigen lateral flow assay: A point-of-care diagnostic at an opportune time
    Tang, Michele W.
    Clemons, Karl V.
    Katzenstein, David A.
    Stevens, David A.
    CRITICAL REVIEWS IN MICROBIOLOGY, 2016, 42 (04) : 634 - 642
  • [13] The need for point-of-care tests for mpox
    Dhillon, Ranu S.
    Karan, Abraar
    Srikrishna, Devabhaktuni
    Mombouli, Jean-Vivien
    LANCET, 2024, 404 (10459): : 1193 - 1194
  • [14] Aspergillus sensitisation detection using point-of-care lateral flow assay in moderate to severe asthma
    Wang, Ran
    Eades, Chris
    Palmer, Maisie
    Platt, Gareth
    Fowler, Stephen J.
    Kosmidis, Chris
    MEDICAL MYCOLOGY, 2023, 61 (08)
  • [15] High Diagnostic Accuracy of a Novel Lateral Flow Assay for the Point-of-Care Detection of SARS-CoV-2
    Giberti, Irene
    Costa, Elisabetta
    Domnich, Alexander
    Ricucci, Valentina
    De Pace, Vanessa
    Garzillo, Giada
    Guarona, Giulia
    Icardi, Giancarlo
    BIOMEDICINES, 2022, 10 (07)
  • [16] Quantitative hematocrit measurement of whole blood in a point-of-care lateral flow device using a smartphone flow tracking app
    Frantz, Eric
    Li, Hua
    Steckl, Andrew J.
    BIOSENSORS & BIOELECTRONICS, 2020, 163 (163):
  • [17] A prototype lateral flow assay for detection of orthopoxviruses
    Ulaeto, David O.
    Lonsdale, Steve G.
    Laidlaw, Stephen M.
    Clark, Graeme C.
    Horby, Peter
    Carroll, Miles W.
    LANCET INFECTIOUS DISEASES, 2022, 22 (09): : 1279 - 1280
  • [18] Point-of-care device for Graves’ disease detection using Infrared Thermography
    Sharma, Vaishali
    Dhingra, Vandana K.
    Kumar, Ashok
    Goswami, Mayank
    e-Journal of Nondestructive Testing, 2022, 27 (11):
  • [19] Lateral and Vertical Flow Assays for Point-of-Care Diagnostics
    Jiang, Nan
    Ahmed, Rajib
    Damayantharan, Mylon
    Unal, Baris
    Butt, Haider
    Yetisen, Ali K.
    ADVANCED HEALTHCARE MATERIALS, 2019, 8 (14)
  • [20] DEVELOPMENT AND EVALUATION OF A QUANTITATIVE LATERAL FLOW IMMUNOASSAY FOR THE DETECTION OF FERRITIN AS POINT-OF-CARE TESTING
    Kimura, Fumiaki
    Miyoshi, Sanami
    Mishima, Yasuo
    Shigeto, Nobuyuki
    Fukuda, Tomoko
    Yamahara, Shigehiro
    Matsumura, Tadashi
    Fujii, Shinji
    Tanimoto, Mitsune
    AMERICAN JOURNAL OF HEMATOLOGY, 2013, 88 (05) : E173 - E173