Toward the quantification of the 13CO2/12CO2 ratio in exhaled mouse breath with mid-infrared hollow waveguide gas sensors

被引:31
|
作者
Wilk, Andreas [1 ]
Seichter, Felicia [1 ]
Kim, Seong-Soo [1 ]
Tuetuencue, Erhan [1 ]
Mizaikoff, Boris [1 ]
Vogt, Josef A. [2 ]
Wachter, Ulrich [2 ]
Radermacher, Peter [2 ]
机构
[1] Univ Ulm, Inst Analyt & Bioanalyt Chem, D-89081 Ulm, Germany
[2] Univ Klinikum Ulm, Klin Anasthesiol, Sekt Anasthesiol Pathophysiol & Verfahrensentwick, D-89073 Ulm, Germany
关键词
FTIR spectroscopy; Mid-infrared gas sensor; Hollow waveguide; Mouse sepsis model; Glucose/insulin metabolism disorder; (CO2)-C-13 enrichment; CRITICALLY-ILL PATIENTS; HELICOBACTER-PYLORI INFECTION; NONDISPERSIVE INFRARED SPECTROMETRY; QUANTUM CASCADE LASERS; FT-IR SPECTROSCOPY; MASS-SPECTROMETRY; ISOTOPE RATIO; CARBON-MONOXIDE; NITRIC-OXIDE; TESTS;
D O I
10.1007/s00216-011-5524-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Mouse sepsis models are used to gain insight into the complex processes involved with patients suffering from glucose metabolism disorders. Measuring the expiratory release of (CO2)-C-13 after administering stable labeled C-13(6)-glucose enables assessment of the in vivo integrity and functionality of key metabolic processes. In the present study, we demonstrate that Fourier transform infrared spectroscopy operating in the mid-infrared spectral regime (2-20 mu m) combined with hollow waveguide gas sensing modules simultaneously serving as a miniaturized gas cell and as a waveguide are capable of quantitatively monitoring (CO2)-C-13 enrichment levels in low volume mouse breath samples.
引用
收藏
页码:397 / 404
页数:8
相关论文
共 50 条
  • [31] Diode laser absorption spectrometry for 13CO2/12CO2 isotope ratio analysis: Investigation on precision and accuracy levels
    A. Castrillo
    G. Casa
    E. Kerstel
    L. Gianfrani
    Applied Physics B, 2005, 81 : 863 - 869
  • [32] Real Time Sensing of 12CO2 and 13CO2 Using 2μm DFB-LD
    Amamoto, Kanto
    Tei, Kazuyoku
    Yamaguchi, Shigeru
    Sakai, Shunichi
    Asobe, Masaki
    Ohba, Takeshi
    2017 22ND MICROOPTICS CONFERENCE (MOC), 2017, : 210 - 211
  • [33] Diode laser absorption spectrometry for 13CO2/12CO2 isotope ratio analysis:: Investigation on precision and accuracy levels
    Castrillo, A
    Casa, G
    Kerstel, E
    Gianfrani, L
    APPLIED PHYSICS B-LASERS AND OPTICS, 2005, 81 (06): : 863 - 869
  • [34] Methods of 14CO2, 13CO2 and 12CO2 detection in gaseous media in real time
    Kireev, S. V.
    Kondrashov, A. A.
    Shnyrev, S. L.
    Simanovsky, I. G.
    LASER PHYSICS, 2017, 27 (10)
  • [35] Systematic errors in diode-laser measuring the relative content of 13CO2 and 12CO2
    Stepanov, E. V.
    QUANTUM ELECTRONICS, 2006, 36 (08) : 731 - 737
  • [36] LEAST-SQUARES ADJUSTMENT OF ANHARMONIC POTENTIAL CONSTANTS - APPLICATION TO 12CO2 AND 13CO2
    PARISEAU, MA
    SUZUKI, I
    OVEREND, J
    JOURNAL OF CHEMICAL PHYSICS, 1965, 42 (07): : 2335 - &
  • [37] Diagnosis of small intestinal bacterial overgrowth in irritable bowel syndrome patients using high-precision stable 13CO2/12CO2 isotope ratios in exhaled breath
    Banik, Gourab D.
    Maity, Abhijit
    Som, Suman
    Ghosh, Chiranjit
    Daschakraborty, Sunil B.
    Chaudhuri, Sujit
    Ghosh, Shibendu
    Pradhan, Manik
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (10) : 1918 - 1924
  • [38] 13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 μm
    Erdélyi, M
    Richter, D
    Tittel, FK
    APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 75 (2-3): : 289 - 295
  • [39] Retrieving the 13CO2/12CO2 isotopic ratio from high resolution ground-based FTIR measurement in Tsukuba
    Rokotyan, N. V.
    Imasu, R.
    Morina, I.
    Gribanov, K. G.
    Zakharov, V. I.
    24TH INTERNATIONAL SYMPOSIUM ON ATMOSPHERIC AND OCEAN OPTICS: ATMOSPHERIC PHYSICS, 2018, 10833
  • [40] 13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 μm
    M. Erdélyi
    D. Richter
    F.K. Tittel
    Applied Physics B, 2002, 75 : 289 - 295