Retrieving the 13CO2/12CO2 isotopic ratio from high resolution ground-based FTIR measurement in Tsukuba

被引:0
|
作者
Rokotyan, N. V. [1 ]
Imasu, R. [2 ]
Morina, I. [3 ]
Gribanov, K. G. [1 ]
Zakharov, V. I. [1 ]
机构
[1] Ural Fed Univ, Str Mira 19, Ekaterinburg 620002, Russia
[2] Univ Tokyo, Atmosphere & Ocean Res Inst, Tokyo, Japan
[3] Natl Inst Environm Studies, Tsukuba, Ibaraki, Japan
基金
俄罗斯科学基金会;
关键词
CO2; isotopes; (CO2)-C-13; remote sensing; climate change; DELTA-D; CO2; COLUMN; PROFILES;
D O I
10.1117/12.2504590
中图分类号
P7 [海洋学];
学科分类号
0707 ;
摘要
In the current research we describe an attempt to retrieve the (CO2)-C-13/(CO2)-C-12 isotopic ratio from high resolution ground based FTIR measurements of atmospheric transmittance spectra recorded with the Bruker IFS 125HR instrument in Tsukuba, Japan. We discuss the retrieval approach, present the obtained results, that demonstrate a seasonal cycle with an amplitude not typical to atmospheric (CO2)-C-13/(CO2)-C-12, and discuss major pitfalls of the retrieval.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Bottlenecks in the remote sensing of the 13CO2/12CO2 isotopic ratio from GOSAT measurements
    Rokotyan, N. V.
    Imasu, R.
    Gribanov, K. G.
    Zakharov, V. I.
    23RD INTERNATIONAL SYMPOSIUM ON ATMOSPHERIC AND OCEAN OPTICS: ATMOSPHERIC PHYSICS, 2017, 10466
  • [2] Determination of 13CO2/12CO2 ratio by IRMS and NDIRS
    Barth, E
    Tugtekin, I
    Weidenbach, H
    Wachter, U
    Vogt, J
    Radermacher, P
    Adler, G
    Georgieff, M
    ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 1997, 33 (1-2) : 209 - 213
  • [3] Measurement of the 13CO2/12CO2 concentration ratio in exhaled air by diode laser spectroscopy
    E. S. Mironchuk
    Bulletin of the Lebedev Physics Institute, 2010, 37 : 180 - 181
  • [5] High Resolution Raman Detection of 12CO2 and 13CO2 Isotopes in Human Breath
    Polishchuk, A. V.
    Kurikova, V. V.
    Grigorenko, K. M.
    Vitkin, V. V.
    INTERNATIONAL CONFERENCE LASER OPTICS 2020 (ICLO 2020), 2020,
  • [6] Precise 13CO2/12CO2 isotopic ratio measurements for breath diagnosis with a 2 μm diode laser
    Sun Mingguo
    Ma Hongliang
    Cao Zhensong
    Liu Kun
    Wang Guishi
    Wang Lei
    Liu Qiang
    Gao Xiaoming
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VI, 2014, 9268
  • [7] Evaluating calibration strategies for isotope ratio infrared spectroscopy for atmospheric 13CO2/12CO2 measurement
    Wen, X. -F.
    Meng, Y.
    Zhang, X. -Y.
    Sun, X. -M.
    Lee, X.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2013, 6 (06) : 1491 - 1501
  • [8] 13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 μm
    Erdélyi, M
    Richter, D
    Tittel, FK
    APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 75 (2-3): : 289 - 295
  • [9] 13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 μm
    M. Erdélyi
    D. Richter
    F.K. Tittel
    Applied Physics B, 2002, 75 : 289 - 295
  • [10] 13CO2/12CO2 isotopic ratio measurements with a continuous-wave quantum cascade laser in exhaled breath
    Kasyutich, Vasili L.
    Martin, Philip A.
    INFRARED PHYSICS & TECHNOLOGY, 2012, 55 (01) : 60 - 66