Precise 13CO2/12CO2 isotopic ratio measurements for breath diagnosis with a 2 μm diode laser

被引:0
|
作者
Sun Mingguo [1 ,2 ]
Ma Hongliang [1 ]
Cao Zhensong [1 ]
Liu Kun [2 ]
Wang Guishi [2 ]
Wang Lei [2 ]
Liu Qiang [1 ]
Gao Xiaoming [2 ]
机构
[1] Chinese Acad Sci, Key Lab Atmospher Composit & Opt Radiat, Hefei 230031, Peoples R China
[2] Chinese Acad Sci, Anhui Inst Optic Fine Mech, Lab Atmospher Physico Chem, Hefei 230031, Peoples R China
关键词
Stable isotopes; Laser spectroscopy; Human breath; Wavelet denoising; Kalman filter; RING-DOWN SPECTROSCOPY; C-13/C-12;
D O I
10.1117/12.2071221
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A laser spectrometer based on a distributed-feedback semiconductor diode laser at 2 mu m is developed to measure the changes of (CO2)-C-13/(CO2)-C-12 isotope ratio in exhaled breath sample with the CO2 concentration of similar to 4%. It is characterized by a simplified optical layout, in which a single detector and associated electronics are used to probe CO2 spectrum. The cell has 10 cm long base length with 26.4 m optical path length in total and 330 cm(3) volume. The cell pressure and temperature are controlled at 50 Torr and 28 degrees C, respectively. The best (13)delta precision of 0.06 parts per thousand was achieved by using wavelet denoising and Kalman filter.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Highly precise and real-time measurements of 13CO2/12CO2 isotopic ratio in breath using a 2 μm diode laser
    Sun Ming-Guo
    Ma Hong-Liang
    Liu Qiang
    Cao Zhen-Song
    Wang Gui-Shi
    Liu Kun
    Huang Yin-Bo
    Gao Xiao-Ming
    Rao Rui-Zhong
    ACTA PHYSICA SINICA, 2018, 67 (06)
  • [2] 13CO2/12CO2 isotopic ratio measurements with a continuous-wave quantum cascade laser in exhaled breath
    Kasyutich, Vasili L.
    Martin, Philip A.
    INFRARED PHYSICS & TECHNOLOGY, 2012, 55 (01) : 60 - 66
  • [3] High precision measurements of the 13CO2/12CO2 isotope ratio at atmospheric pressure in human breath using a 2 μm diode laser
    Andreev, S. N.
    Mironchuk, E. S.
    Nikolaev, I. V.
    Ochkin, V. N.
    Spiridonov, M. V.
    Tskhai, S. N.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2011, 104 (01): : 73 - 79
  • [4] High precision measurements of the 13CO2/12CO2 isotope ratio at atmospheric pressure in human breath using a 2 μm diode laser
    S. N. Andreev
    E. S. Mironchuk
    I. V. Nikolaev
    V. N. Ochkin
    M. V. Spiridonov
    S. N. Tskhai
    Applied Physics B, 2011, 104 : 73 - 79
  • [5] Precise measurements of the total concentration of atmospheric CO2 and 13CO2/12CO2 isotopic ratio using a lead-salt laser diode spectrometer
    Croize, Laurence
    Mondelain, Didier
    Camy-Peyret, Claude
    Delmotte, Marc
    Schmidt, Martina
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (04):
  • [6] Bottlenecks in the remote sensing of the 13CO2/12CO2 isotopic ratio from GOSAT measurements
    Rokotyan, N. V.
    Imasu, R.
    Gribanov, K. G.
    Zakharov, V. I.
    23RD INTERNATIONAL SYMPOSIUM ON ATMOSPHERIC AND OCEAN OPTICS: ATMOSPHERIC PHYSICS, 2017, 10466
  • [7] Measurement of the 13CO2/12CO2 concentration ratio in exhaled air by diode laser spectroscopy
    E. S. Mironchuk
    Bulletin of the Lebedev Physics Institute, 2010, 37 : 180 - 181
  • [9] 13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 μm
    Erdélyi, M
    Richter, D
    Tittel, FK
    APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 75 (2-3): : 289 - 295
  • [10] 13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 μm
    M. Erdélyi
    D. Richter
    F.K. Tittel
    Applied Physics B, 2002, 75 : 289 - 295