Diagnosis of small intestinal bacterial overgrowth in irritable bowel syndrome patients using high-precision stable 13CO2/12CO2 isotope ratios in exhaled breath

被引:9
|
作者
Banik, Gourab D. [1 ]
Maity, Abhijit [1 ]
Som, Suman [1 ]
Ghosh, Chiranjit [1 ]
Daschakraborty, Sunil B. [2 ]
Chaudhuri, Sujit [2 ]
Ghosh, Shibendu [3 ]
Pradhan, Manik [1 ,4 ]
机构
[1] SN Bose Natl Ctr Basic Sci, Dept Chem Biol & Macromol Sci, Kolkata 700098, India
[2] AMRI Hosp, Dept Gastroenterol, Kolkata 700098, India
[3] Vivekananda Inst Med Sci, Dept Med, Kolkata 700027, India
[4] SN Bose Natl Ctr Basic Sci, Themat Unit Excellence Nanodevice Technol, Kolkata 700098, India
关键词
20;
D O I
10.1039/c4ja00186a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydrogen breath tests (HBT) are widely used for the diagnosis of small intestinal bacterial overgrowth (SIBO) in patients with irritable bowel syndrome (IBS). However, the conclusions drawn from these studies are highly controversial, and several discrepancies exist in the results. The aim of our study is to develop an alternative C-13-glucose breath test (C-13-GBT) methodology by measuring high-precision (CO2)-C-13/(CO2)-C-12 isotope ratios in exhaled breath to accurately diagnose SIBO using an optical cavity-enhanced CO2 isotope analyzer. In all, 118 diarrhea-predominant (IBS-D) patients diagnosed according to ROME III criteria underwent C-13-GBT and HBT following the ingestion of a test meal containing 50 mg C-13-enriched glucose with 50 g glucose. The excretion of (CO2)-C-13 enrichments and a cumulative percentage dose of C-13-recovered (c-PDR) significantly depleted (p < 0.001) for the positive SIBO patients (n = 25) compared to the patients with negative SIBO (n = 53) as diagnosed by HBT. A cut-off value of 5.47 parts per thousand at 45 min was indicative of a positive SIBO syndrome. Subsequently, a portion of IBS-D individuals (n = 20) whose HBTs were negative but C-13-GBTs were positive, suggesting HBT often fails to diagnose SIBO when the patients may have "non-hydrogen-producing" bacteria. C-13-GBT also correctly diagnosed SIBO in patients (n = 20) within the "grey-zone" and during the preclinical phase of SIBO as opposed to HBT. The prevalence of SIBO with IBS-D in Indian population was estimated to be 45.7%. Our study demonstrates C-13-GBT, for the first time, as a clinically valid and sufficiently robust alternative diagnostic methodology for an accurate evaluation of SIBO in IBS-D patients and superior to HBT.
引用
收藏
页码:1918 / 1924
页数:7
相关论文
共 29 条
  • [1] High precision measurements of the 13CO2/12CO2 isotope ratio at atmospheric pressure in human breath using a 2 μm diode laser
    Andreev, S. N.
    Mironchuk, E. S.
    Nikolaev, I. V.
    Ochkin, V. N.
    Spiridonov, M. V.
    Tskhai, S. N.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2011, 104 (01): : 73 - 79
  • [2] High precision measurements of the 13CO2/12CO2 isotope ratio at atmospheric pressure in human breath using a 2 μm diode laser
    S. N. Andreev
    E. S. Mironchuk
    I. V. Nikolaev
    V. N. Ochkin
    M. V. Spiridonov
    S. N. Tskhai
    Applied Physics B, 2011, 104 : 73 - 79
  • [3] High precision 2.0 μm Photoacoustic Spectrometer for Determination of the 13CO2/12CO2 Isotope Ratio
    Reed, Z. D.
    Hodges, J. T.
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2017,
  • [4] High-precision determination of the 13CO2/12CO2 isotope ratio using a portable 2.008-μm diode-laser spectrometer
    G. Gagliardi
    A. Castrillo
    R.Q. Iannone
    E.R.T. Kerstel
    L. Gianfrani
    Applied Physics B, 2003, 77 : 119 - 124
  • [5] Multivariate determination of 13CO2/12CO2 ratios in exhaled mouse breath with mid-infrared hollow waveguide gas sensors
    Felicia Seichter
    Andreas Wilk
    Katharina Wörle
    Seong-Soo Kim
    Josef A. Vogt
    Ulrich Wachter
    Peter Radermacher
    Boris Mizaikoff
    Analytical and Bioanalytical Chemistry, 2013, 405 : 4945 - 4951
  • [6] Multivariate determination of 13CO2/12CO2 ratios in exhaled mouse breath with mid-infrared hollow waveguide gas sensors
    Seichter, Felicia
    Wilk, Andreas
    Woerle, Katharina
    Kim, Seong-Soo
    Vogt, Josef A.
    Wachter, Ulrich
    Radermacher, Peter
    Mizaikoff, Boris
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (14) : 4945 - 4951
  • [7] High-precision determination of the 13CO2/12CO2 isotope ratio using a portable 2.008-μm diode-laser spectrometer
    Gagliardi, G
    Castrillo, A
    Iannone, RQ
    Kerstel, ERT
    Gianfrani, L
    APPLIED PHYSICS B-LASERS AND OPTICS, 2003, 77 (01): : 119 - 124
  • [8] High Resolution Raman Detection of 12CO2 and 13CO2 Isotopes in Human Breath
    Polishchuk, A. V.
    Kurikova, V. V.
    Grigorenko, K. M.
    Vitkin, V. V.
    INTERNATIONAL CONFERENCE LASER OPTICS 2020 (ICLO 2020), 2020,
  • [9] Changes in exhaled 13CO2/12CO2 breath delta value as an early indicator of infection in intensive care unit patients
    O'Rourke, Ann P.
    Buckman, Sara A.
    Evans, David C.
    Kerwin, Andrew J.
    Breunig, Emily A.
    Butz, Daniel E.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2019, 86 (01): : 71 - 78
  • [10] 13CO2/12CO2 isotopic ratio measurements with a continuous-wave quantum cascade laser in exhaled breath
    Kasyutich, Vasili L.
    Martin, Philip A.
    INFRARED PHYSICS & TECHNOLOGY, 2012, 55 (01) : 60 - 66