Accuracy, precision, usability, and cost of free chlorine residual testing methods

被引:27
|
作者
Murray, Anna [1 ]
Lantagne, Daniele [1 ]
机构
[1] Tufts Univ, Dept Civil & Environm Engn, Medford, MA 02155 USA
基金
美国国家科学基金会;
关键词
chlorination; developing countries; drinking water; field testing methods; free chlorine residual; household water treatment;
D O I
10.2166/wh.2014.195
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Chlorine is the most widely used disinfectant worldwide, partially because residual protection is maintained after treatment. This residual is measured using colorimetric test kits varying in accuracy, precision, training required, and cost. Seven commercially available colorimeters, color wheel and test tube comparator kits, pool test kits, and test strips were evaluated for use in low-resource settings by: (1) measuring in quintuplicate 11 samples from 0.0-4.0 mg/L free chlorine residual in laboratory and natural light settings to determine accuracy and precision; (2) conducting volunteer testing where participants used and evaluated each test kit; and (3) comparing costs. Laboratory accuracy ranged from 5.1-40.5% measurement error, with colorimeters the most accurate and test strip methods the least. Variation between laboratory and natural light readings occurred with one test strip method. Volunteer participants found test strip methods easiest and color wheel methods most difficult, and were most confident in the colorimeter and least confident in test strip methods. Costs range from 3.50-444 USD for 100 tests. Application of a decision matrix found colorimeters and test tube comparator kits were most appropriate for use in low-resource settings; it is recommended users apply the decision matrix themselves, as the appropriate kit might vary by context.
引用
收藏
页码:79 / 90
页数:12
相关论文
共 50 条
  • [1] Accuracy, precision, usability, and cost of portable silver test methods for ceramic filter factories
    Meade, Rhiana D.
    Murray, Anna L.
    Mittelman, Anjuliee M.
    Rayner, Justine
    Lantagne, Daniele S.
    JOURNAL OF WATER AND HEALTH, 2017, 15 (01) : 72 - 82
  • [2] ACCURACY AND PRECISION ENHANCEMENT FOR TOTAL RESIDUAL CHLORINE BACK TITRATION
    STOCKMEIER, LA
    HUBER, CO
    KOHL, JE
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1987, 59 (12): : 1075 - 1077
  • [3] Accuracy, Precision, Ease-Of-Use, and Cost of Methods to Test Ebola-Relevant Chlorine Solutions
    Wells, Emma
    Wolfe, Marlene K.
    Murray, Anna
    Lantagne, Daniele
    PLOS ONE, 2016, 11 (05):
  • [4] AN EVALUATION OF METHODS FOR DETERMINING RESIDUAL CHLORINE IN WATER .I. FREE CHLORINE
    NICOLSON, NJ
    ANALYST, 1965, 90 (1069) : 187 - &
  • [5] Accuracy Issues in Free Thyroxine Testing Methods
    Nelson, Jerald C.
    Yoo, Elliot W.
    Wilcox, R. Bruce
    SEMINARS IN PERINATOLOGY, 2008, 32 (06) : 403 - 406
  • [6] RESIDUAL CHLORINE METHODS AND DISINFECTION OF SEWAGE
    DAY, RV
    HORCHLER, DH
    MARKS, HC
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1953, 45 (05): : 1001 - 1004
  • [7] Diagnostic accuracy and usability of home calprotectin testing
    Thomas, A.
    Clarke, M.
    Cairns, V.
    Goodhand, J.
    Ahmad, T.
    Kennedy, N.
    JOURNAL OF CROHNS & COLITIS, 2019, 13 : S281 - S281
  • [8] Considerations and Methods for Usability Testing with Children
    Andersen, Malene Hjortboe
    Khalid, Md. Saifuddin
    Brooks, Eva Irene
    INTERACTIVITY, GAME CREATION, DESIGN, LEARNING, AND INNOVATION, 2018, 196 : 228 - 238
  • [9] On the assessment of usability testing methods for children
    Markopoulos, P
    Bekker, M
    INTERACTING WITH COMPUTERS, 2003, 15 (02) : 227 - 243
  • [10] Hydraulic mixing and free chlorine residual in reservoirs
    Boulos, PF
    Grayman, WM
    Bowcock, RW
    Clapp, JW
    Rossman, LA
    Clark, RM
    Deininger, RA
    Dhingra, AK
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1996, 88 (07): : 48 - 59