Accuracy, precision, usability, and cost of free chlorine residual testing methods

被引:27
|
作者
Murray, Anna [1 ]
Lantagne, Daniele [1 ]
机构
[1] Tufts Univ, Dept Civil & Environm Engn, Medford, MA 02155 USA
基金
美国国家科学基金会;
关键词
chlorination; developing countries; drinking water; field testing methods; free chlorine residual; household water treatment;
D O I
10.2166/wh.2014.195
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Chlorine is the most widely used disinfectant worldwide, partially because residual protection is maintained after treatment. This residual is measured using colorimetric test kits varying in accuracy, precision, training required, and cost. Seven commercially available colorimeters, color wheel and test tube comparator kits, pool test kits, and test strips were evaluated for use in low-resource settings by: (1) measuring in quintuplicate 11 samples from 0.0-4.0 mg/L free chlorine residual in laboratory and natural light settings to determine accuracy and precision; (2) conducting volunteer testing where participants used and evaluated each test kit; and (3) comparing costs. Laboratory accuracy ranged from 5.1-40.5% measurement error, with colorimeters the most accurate and test strip methods the least. Variation between laboratory and natural light readings occurred with one test strip method. Volunteer participants found test strip methods easiest and color wheel methods most difficult, and were most confident in the colorimeter and least confident in test strip methods. Costs range from 3.50-444 USD for 100 tests. Application of a decision matrix found colorimeters and test tube comparator kits were most appropriate for use in low-resource settings; it is recommended users apply the decision matrix themselves, as the appropriate kit might vary by context.
引用
收藏
页码:79 / 90
页数:12
相关论文
共 50 条
  • [31] ACCURACY AND PRECISION OF METHODS FOR ESTIMATING RIVER LOADS
    FERGUSON, RI
    EARTH SURFACE PROCESSES AND LANDFORMS, 1987, 12 (01) : 95 - 104
  • [32] Usability testing with children: an application of Pedactice and Ticese methods
    Carusi, Alessandra
    Mont'Alvao, Claudia
    WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2012, 41 : 822 - 826
  • [33] Bullet trajectory reconstruction - Methods, accuracy and precision
    Mattijssen, Erwin J. A. T.
    Kerkhoff, Wim
    FORENSIC SCIENCE INTERNATIONAL, 2016, 262 : 204 - 211
  • [34] Methods and Procedures to Usability Testing in Virtual Reality Systems
    Pontes de Franca, Ana Carol
    Pereira Neto, J.
    Soares, Marcelo Marcio
    ADVANCES IN ERGONOMICS IN DESIGN (AHFE 2017), 2018, 588 : 45 - 51
  • [35] Creative low-budget usability testing methods
    Reilly, MT
    Hogan, CN
    STC's 52nd Annual Conference Proceedings: EXPERIENCING TECHNICAL COMMUNICATION, 2005, : 225 - 230
  • [36] Decay of Free Residual Chlorine in Wells Water of Northern Brazil
    Vargas, Taise Ferreira
    Baia, Celia Ceolin
    da Silva Machado, Tatiana Lemos
    Dorea, Caetano Chang
    Bastos, Wanderley Rodrigues
    WATER, 2021, 13 (07)
  • [37] Comparison of methods and kits for colorimetric determination of residual chlorine in water
    Serrat, FB
    Morell, GB
    Polo, DR
    JOURNAL OF AOAC INTERNATIONAL, 1997, 80 (05) : 1117 - 1121
  • [38] Low-cost free-chlorine sensor
    Pan, Si
    Deen, M. Jamal
    Ghosh, Raja
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [39] Improving the Accuracy and Precision of Cognitive Testing in Mild Dementia
    Wouters, Hans
    Appels, Bregje
    van der Flier, Wiesje M.
    van Campen, Jos
    Klein, Martin
    Zwinderman, Aeilko H.
    Schmand, Ben
    van Gool, Willem A.
    Scheltens, Philip
    Lindeboom, Robert
    JOURNAL OF THE INTERNATIONAL NEUROPSYCHOLOGICAL SOCIETY, 2012, 18 (02) : 314 - 322
  • [40] PRECISION AND ACCURACY - CONCEPTS AND ASSESSMENT BY METHOD EVALUATION TESTING
    WESTGARD, JO
    CRC CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 1981, 13 (04): : 283 - 330