Technical Note: Commissioning of an ultrasound-compatible surrogate vaginal cylinder for transvaginal ultrasound-based gynecologic high-dose-rate brachytherapy

被引:4
|
作者
Van Elburg, Devin [1 ,2 ]
Roumeliotis, Michael [1 ,2 ,3 ]
Fenster, Aaron [4 ,5 ]
Phan, Tien [3 ]
Meyer, Tyler [1 ,2 ,3 ]
机构
[1] Univ Calgary, Dept Phys & Astron, Calgary, AB T2N 1N4, Canada
[2] Tom Baker Canc Clin, Med Phys Dept, Calgary, AB, Canada
[3] Univ Calgary, Dept Oncol, Calgary, AB, Canada
[4] Univ Western Ontario, Sch Biomed Engn, London, ON, Canada
[5] Univ Western Ontario, Robarts Res Inst, London, ON, Canada
关键词
brachytherapy; commissioning; gynecologic; ultrasound; GUIDED ADAPTIVE BRACHYTHERAPY; TRANSRECTAL ULTRASOUND; IMAGE REGISTRATION; CERVIX CANCER; QUALITY;
D O I
10.1002/mp.15559
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To provide a comprehensive set of commissioning tests for clinical implementation of three-dimensional transvaginal ultrasound (3D TVUS) as a replacement of computed tomography (CT) for applicator reconstruction in gynecologic (GYN) intracavitary high-dose-rate brachytherapy (HDRBT) with a multi-channel vaginal cylinder (MCVC). Methods We introduce an ultrasound-compatible "surrogate" vaginal cylinder (SVC) for reconstruction of Elekta's CT-MR Multi Channel Applicator (MCVC) in 3D TVUS. The MCVC is digitized over the SVC in 3DUS using digital library model overlay. Consulting guidelines from various sources (CPQR, GEC-ESTRO, AAPM), we identify and describe three tests specific to commissioning the SVC: (1) verification of SVC outer dimensions, (2) source position accuracy of MCVC digitization over the SVC in 3D TVUS, and (3) MRI/US registration error. Results The SVC outer dimensions (diameter and A-D marker locations) were well matched to the MCVC, however a 0.6 mm discrepancy in length between cylinder tips was observed. Source position accuracy was within 1 mm (tolerance recommended by CPQR) when reconstructing the MCVC in 3D TVUS. Dice similarity coefficients and target registration error for MRI/3D TVUS registration was similar to MRI/CT registration, which is the clinical standard. Conclusions These commissioning tests are performed using institutional equipment but provide the framework for any practitioner to repeat in their own setup, to demonstrate safe adoption of the 3D TVUS system for patient treatments. We demonstrate that MRI/US-based workflow achieves similar source position accuracy and image registration error as standard MRI/CT, which is consistent with standard tolerances. This is a critical step toward replacement of CT with US in GYN HDRBT treatments with the MCVC.
引用
收藏
页码:2203 / 2211
页数:9
相关论文
共 50 条
  • [31] Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy
    Peach, Matthew Sean
    Moore, Joanna
    Giles, Wallis
    Trainor, Justin
    Long, Tim
    Moon, Nicholas
    Hylton, Joseph E.
    Showalter, Timothy N.
    Libby, Bruce
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2018, 10 (04) : 306 - 314
  • [32] 3D ultrasound system for needle guidance during high-dose-rate interstitial gynecologic brachytherapy implant placement procedures
    Rodgers, Jessica R.
    Bax, Jeffrey
    Rascevska, Elina
    Velker, Vikram
    Surry, Kathleen
    D'Souza, David
    Leung, Eric
    Fenster, Aaron
    MEDICAL IMAGING 2019: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2019, 10951
  • [33] Toward a 3D transrectal ultrasound system for verification of needle placement during high-dose-rate interstitial gynecologic brachytherapy
    Rodgers, Jessica Robin
    Surry, Kathleen
    Leung, Eric
    D'Souza, David
    Fenster, Aaron
    MEDICAL PHYSICS, 2017, 44 (05) : 1899 - 1911
  • [34] Enabling 3D Ultrasound Needle Guidance During Implant Placement Procedures for High-Dose-Rate Interstitial Gynecologic Brachytherapy
    Rodgers, J.
    Bax, J.
    Surry, K.
    Hrinivich, W.
    Rascevska, E.
    Leung, E.
    Velker, V.
    D'Souza, D.
    Fenster, A.
    MEDICAL PHYSICS, 2019, 46 (06) : E256 - E257
  • [35] One-step ultrasound-based high dose rate (HDR) prostate brachytherapy with dose escalation to the dominant intraprostatic lesion
    Crook, Juanita M.
    Ots, Ana
    Parker, Brent
    Schmid, Matt
    Batchelar, Deidre
    Araujo, Cynthia
    Hilts, Michelle
    Bachand, Francois
    JOURNAL OF CLINICAL ONCOLOGY, 2014, 32 (04)
  • [36] Optimization of high-dose-rate cervix brachytherapy applicator placement: The benefits of intraoperative ultrasound guidance
    Davidson, Melanie T. M.
    Yuen, Jasper
    D'Souza, David P.
    Radwan, John S.
    Hammond, J. Alex
    Batchelar, Deidre L.
    BRACHYTHERAPY, 2008, 7 (03) : 248 - 253
  • [37] The influence of a rectal ultrasound probe on the separation between prostate and rectum in high-dose-rate brachytherapy
    Rylander, Susanne
    Buus, Simon
    Bentzen, Lise
    Pedersen, Erik Morre
    Tanderup, Kari
    BRACHYTHERAPY, 2015, 14 (05) : 711 - 717
  • [38] Electromagnetic tracking for catheter reconstruction in ultrasound-guided high-dose-rate brachytherapy of the prostate
    Bharat, Shyam
    Kung, Cynthia
    Dehghan, Ehsan
    Ravi, Ananth
    Venugopal, Niranjan
    Bonillas, Antonio
    Stanton, Doug
    Kruecker, Jochen
    BRACHYTHERAPY, 2014, 13 (06) : 640 - 650
  • [39] Dosimetric comparison of multichannel with one single-channel vaginal cylinder for vaginal cancer treatments with high-dose-rate brachytherapy
    Kim, Hayeon
    Rajagopalan, Malolan S.
    Houser, Chris
    Beriwal, Sushil
    BRACHYTHERAPY, 2014, 13 (03) : 263 - 267
  • [40] Parametrisation of Dose to the Mucosa of the Anterior Rectal Wall in Transrectal Ultrasound Guided High-Dose-Rate Brachytherapy of the Prostate
    Aitkenhead, A.
    Hamlett, L.
    Wood, D.
    Choudhury, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 177 - 177