Technical Note: Commissioning of an ultrasound-compatible surrogate vaginal cylinder for transvaginal ultrasound-based gynecologic high-dose-rate brachytherapy

被引:4
|
作者
Van Elburg, Devin [1 ,2 ]
Roumeliotis, Michael [1 ,2 ,3 ]
Fenster, Aaron [4 ,5 ]
Phan, Tien [3 ]
Meyer, Tyler [1 ,2 ,3 ]
机构
[1] Univ Calgary, Dept Phys & Astron, Calgary, AB T2N 1N4, Canada
[2] Tom Baker Canc Clin, Med Phys Dept, Calgary, AB, Canada
[3] Univ Calgary, Dept Oncol, Calgary, AB, Canada
[4] Univ Western Ontario, Sch Biomed Engn, London, ON, Canada
[5] Univ Western Ontario, Robarts Res Inst, London, ON, Canada
关键词
brachytherapy; commissioning; gynecologic; ultrasound; GUIDED ADAPTIVE BRACHYTHERAPY; TRANSRECTAL ULTRASOUND; IMAGE REGISTRATION; CERVIX CANCER; QUALITY;
D O I
10.1002/mp.15559
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To provide a comprehensive set of commissioning tests for clinical implementation of three-dimensional transvaginal ultrasound (3D TVUS) as a replacement of computed tomography (CT) for applicator reconstruction in gynecologic (GYN) intracavitary high-dose-rate brachytherapy (HDRBT) with a multi-channel vaginal cylinder (MCVC). Methods We introduce an ultrasound-compatible "surrogate" vaginal cylinder (SVC) for reconstruction of Elekta's CT-MR Multi Channel Applicator (MCVC) in 3D TVUS. The MCVC is digitized over the SVC in 3DUS using digital library model overlay. Consulting guidelines from various sources (CPQR, GEC-ESTRO, AAPM), we identify and describe three tests specific to commissioning the SVC: (1) verification of SVC outer dimensions, (2) source position accuracy of MCVC digitization over the SVC in 3D TVUS, and (3) MRI/US registration error. Results The SVC outer dimensions (diameter and A-D marker locations) were well matched to the MCVC, however a 0.6 mm discrepancy in length between cylinder tips was observed. Source position accuracy was within 1 mm (tolerance recommended by CPQR) when reconstructing the MCVC in 3D TVUS. Dice similarity coefficients and target registration error for MRI/3D TVUS registration was similar to MRI/CT registration, which is the clinical standard. Conclusions These commissioning tests are performed using institutional equipment but provide the framework for any practitioner to repeat in their own setup, to demonstrate safe adoption of the 3D TVUS system for patient treatments. We demonstrate that MRI/US-based workflow achieves similar source position accuracy and image registration error as standard MRI/CT, which is consistent with standard tolerances. This is a critical step toward replacement of CT with US in GYN HDRBT treatments with the MCVC.
引用
收藏
页码:2203 / 2211
页数:9
相关论文
共 50 条
  • [1] Image Quality Through Ultrasound-Compatible Cylinders for Transvaginal Ultrasound-Guided Gynecologic High-Dose-Rate Brachytherapy
    Elburg, D. V.
    Roumeliotis, M.
    Fenster, A.
    Rodgers, J.
    Meyer, T.
    MEDICAL PHYSICS, 2020, 47 (06) : E790 - E790
  • [2] Monte Carlo dosimetry of a sonolucent vaginal cylinder for three-dimensional transvaginal ultrasound guidance in high-dose-rate interstitial gynecologic brachytherapy
    Van Elburg, Devin
    Morrison, Hali
    Rodgers, Jessica
    Fenster, Aaron
    Roumeliotis, Michael
    Meyer, Tyler
    MEDICAL PHYSICS, 2019, 46 (11) : 5397 - 5397
  • [3] Prostate high-dose-rate brachytherapy: Transrectal ultrasound based planning, a technical note
    Morton, Gerard C.
    PRACTICAL RADIATION ONCOLOGY, 2015, 5 (04) : 238 - 240
  • [4] Dosimetry of a sonolucent material for an ultrasound -compatible gynecologic high-dose-rate brachytherapy cylinder using Monte Carlo simulation and radiochromic film
    Van Elburg, Devin J.
    Roumeliotis, Michael
    Morrison, Hali
    Rodgers, Jessica R.
    Fenster, Aaron
    Meyer, Tyler
    BRACHYTHERAPY, 2021, 20 (01) : 265 - 271
  • [5] Applicability and dosimetric impact of ultrasound-based preplanning in high-dose-rate brachytherapy of prostate cancer
    Aebersold, DM
    Isaak, B
    Thalmann, G
    Behrensmeier, F
    Kolotas, C
    Kranzbühler, H
    Mini, R
    Greiner, RH
    STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 (06) : 351 - 357
  • [6] A semiautomatic segmentation method for interstitial needles in intraoperative 3D transvaginal ultrasound images for high-dose-rate gynecologic brachytherapy of vaginal tumors
    Rodgers, Jessica Robin
    Hrinivich, William Thomas
    Surry, Kathleen
    Velker, Vikram
    D'Souza, David
    Fenster, Aaron
    BRACHYTHERAPY, 2020, 19 (05) : 659 - 668
  • [7] Automatic needle localization in intraoperative 3D transvaginal ultrasound images for high-dose-rate interstitial gynecologic brachytherapy
    Rodgers, Jessica R.
    Gillies, Derek J.
    Hrinivich, William T.
    Gyackov, Igor
    Fenster, Aaron
    MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11315
  • [8] A risk-based approach to development of ultrasound-based high-dose-rate prostate brachytherapy quality management
    Poder, Joel
    Brown, Ryan
    Howie, Andrew
    Yuen, Johnson
    Ralston, Anna
    Schreiber, Kristine
    Bece, Andrej
    Bucci, Joseph
    BRACHYTHERAPY, 2018, 17 (05) : 788 - 793
  • [9] Introduction of inverse dose optimization for ultrasound-based high-dose-rate boost brachytherapy: How we do it in Kiel
    Siebert, Frank-Andre
    Wolf, Sabine
    Bertermann, Hagen
    Nuemberg, Nils
    Bockelmann, Gunnar
    Kimmig, Bernhard
    BRACHYTHERAPY, 2014, 13 (03) : 250 - 256
  • [10] Intraoperative 360-deg three-dimensional transvaginal ultrasound during needle insertions for high-dose-rate transperineal interstitial gynecologic brachytherapy of vaginal tumors
    Rodgers, Jessica Robin
    Bax, Jeffrey
    Surry, Kathleen
    Velker, Vikram
    Leung, Eric
    D'Souza, David
    Fenster, Aaron
    JOURNAL OF MEDICAL IMAGING, 2019, 6 (02)