Development and Validation of a Clinical CT System Simulator

被引:1
|
作者
Tunissen, S. A. M. [1 ]
Oostveen, L. J. [1 ]
Moriakov, N. [1 ,2 ]
Teuwen, J. [1 ,2 ]
Michielsen, K. [1 ]
Smit, E. J. [1 ]
Sechopoulos, I [1 ,3 ,4 ]
机构
[1] Radboudumc, Dept Med Imaging, Nijmegen, Netherlands
[2] Netherlands Canc Inst, AI Oncol, Amsterdam, Netherlands
[3] Dutch Expert Ctr Screening LRCB, Nijmegen, Netherlands
[4] Univ Twente, Tech Med Ctr, Enschede, Netherlands
关键词
CT; computer simulations; system characterization;
D O I
10.1117/12.2611323
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Many advanced reconstruction and image processing methods are being developed with the aim of improving image quality in CT. Development and testing of these methods is aided by the ability to simulate realistic images, to both control the acquisition process and be able to use digital phantoms with known ground truth. Therefore, in this work, we present a method to simulate realistic scanner-specific sinograms from digital phantoms. For this, a series of measurements was conducted on a clinical CT system to characterize resolution loss, noise characteristics, and the exposure-to-detector output relationship. These measurements were used to develop a simulation pipeline, which involves raytracing of a digital phantom, taking into account the focal spot size and gantry rotation, followed by the use of Lambert's Law to determine the amount of energy arriving at each detector element. The spectrum for the specific tube voltage and current was modeled using previously published spectral models. The resulting sinogram was then corrupted, by applying the measured detector Modulation Transfer Function (MTF), and adding noise based on the Noise Power Spectrum (NPS) and mean-variance relationship. Simulator results were compared to those acquired with the CT system in our clinic, showing an average difference of 2.1% in the off-center MTF magnitude, 4.6% in normalized NPS magnitude and only 6 and 5 Hounsfield Units (HU) difference in the voxel values for water and air, respectively. The developed simulator seems capable of generating realistic CT images, which can help researchers develop and test their algorithms.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Automatic mass balancing system for a dynamic CubeSat attitude simulator: development and experimental validation
    Anton Bahu
    Dario Modenini
    CEAS Space Journal, 2020, 12 : 597 - 611
  • [22] Automatic mass balancing system for a dynamic CubeSat attitude simulator: development and experimental validation
    Bahu, Anton
    Modenini, Dario
    CEAS SPACE JOURNAL, 2020, 12 (04) : 597 - 611
  • [23] Validation of a CT-based simulator against a sawmill yield
    Chiorescu, S
    Grönlund, A
    FOREST PRODUCTS JOURNAL, 2000, 50 (06) : 69 - 76
  • [24] Development of a helical CT simulator: An experimental study
    Nagata, Y
    Yamamoto, M
    Kokubo, M
    Okajima, K
    Mizowaki, T
    Katakura, Y
    RADIOLOGY, 1997, 205 : 1246 - 1246
  • [25] Validation of a fast simulator for clinical SPECT simulation.
    De Jong, HW
    Gieles, M
    Ljungberg, M
    Beekman, FJ
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 141P - 141P
  • [26] Small-footprint Laser Scanning Simulator for System Validation, Error Assessment, and Algorithm Development
    Kukko, Antero
    Hyyppa, Juha
    PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 2009, 75 (10): : 1177 - 1189
  • [27] Development and validation of a low dose simulator for computed tomography
    Joemai, R. M. S.
    Geleijns, J.
    Veldkamp, W. J. H.
    EUROPEAN RADIOLOGY, 2010, 20 (04) : 958 - 966
  • [28] Development and Validation of the LWR-IM Traffic Simulator
    Ng, Kok Mun
    Reaz, Mamun Ibne
    2017 7TH IEEE INTERNATIONAL CONFERENCE ON CONTROL SYSTEM, COMPUTING AND ENGINEERING (ICCSCE), 2017, : 40 - 44
  • [29] Development and validation of a low dose simulator for computed tomography
    R. M. S. Joemai
    J. Geleijns
    W. J. H. Veldkamp
    European Radiology, 2010, 20 : 958 - 966
  • [30] DEVELOPMENT AND VALIDATION OF A PROCESS SIMULATOR FOR DRYING SUBBITUMINOUS COAL
    LI, YH
    SKINNER, JL
    CHEMICAL ENGINEERING COMMUNICATIONS, 1986, 49 (1-3) : 99 - 118